Transition edge sensor based detector: from X-ray to $γ$-ray
Authors:
Shuo Zhang,
Jing-Kai Xia,
Tao Sun,
Wen-Tao Wu,
Bing-Jun Wu,
Yong-Liang Wang,
Robin Cantor,
Ke Han,
Xiao-Peng Zhou,
Hao-Ran Liu,
Fu-You Fan,
Si-Ming Guo,
Jun-Cheng Liang,
De-Hong Li,
Yan-Ru Song,
Xu-Dong Ju,
Qiang Fu,
Zhi Liu
Abstract:
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies below 10 keV have very weak penetrating ability, so only a few microns thick of gold or bismuth can obtain quantum efficiency higher than 70\%. Therefore, the en…
▽ More
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies below 10 keV have very weak penetrating ability, so only a few microns thick of gold or bismuth can obtain quantum efficiency higher than 70\%. Therefore, the entire structure of the TES X-ray detector in this energy range can be realized in the microfabrication process. However, for X-rays or gamma rays from 10 keV to 200 keV, sub-millimeter absorber layers are required, which cannot be realized by microfabrication process. This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems built by ShanghaiTech University, then focus on the introduction of the TES $γ$-ray detector, with absorber based on an sub-millimeter lead-tin alloy sphere. The detector has a quantum efficiency above 70\% near 100 keV, and an energy resolution of about 161.5eV@59.5keV.
△ Less
Submitted 26 April, 2022; v1 submitted 1 April, 2022;
originally announced April 2022.
-
Low Noise Frequency Domain Multiplexing of TES Bolometers using Sub-kelvin SQUIDs
Authors:
Tucker Elleflot,
Aritoki Suzuki,
Kam Arnold,
Chris Bebek,
Robin H. Cantor,
Kevin T. Crowley,
John Groh,
Tijmen de Haan,
Amber Hornsby,
John Joseph,
Adrian T. Lee,
Tiffany Liu,
Joshua Montgomery,
Megan Russell,
Qingyang Yu
Abstract:
Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of Transition Edge Sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3G with multiplexing factors as high as 68, and is the baseline readout te…
▽ More
Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of Transition Edge Sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3G with multiplexing factors as high as 68, and is the baseline readout technology for the planned satellite mission LiteBIRD. Here, we present recent work focused on improving DfMux readout noise, reducing parasitic impedance, and improving sensor operation. We have achieved a substantial reduction in stray impedance by integrating the sensors, resonators, and SQUID array onto a single carrier board operated at 250 mK. This also drastically simplifies the packaging of the cryogenic components and leads to better-controlled crosstalk. We demonstrate a low readout noise level of 8.6 pA/Hz$^{-1/2}$, which was made possible by operating the SQUID array at a reduced temperature and with a low dynamic impedance. This is a factor of two improvement compared to the achieved readout noise level in currently operating Cosmic Microwave Background experiments using DfMux and represents a critical step toward maturation of the technology for the next generation of instruments.
△ Less
Submitted 4 December, 2021;
originally announced December 2021.
-
Recent Advances in Frequency-Multiplexed TES Readout: Vastly Reduced Parasitics and an Increase in Multiplexing Factor with sub-Kelvin SQUIDs
Authors:
T. de Haan,
A. Suzuki,
S. T. P. Boyd,
R. H. Cantor,
A. Coerver,
M. A. Dobbs,
R. Hennings-Yeomans,
W. L. Holzapfel,
A. T. Lee,
G. I. Noble,
G. Smecher,
J. Zhou
Abstract:
Cosmic microwave background (CMB) measurements are fundamentally limited by photon statistics. Therefore, ground-based CMB observatories have been increasing the number of detectors that are simultaneously observing the sky. Thanks to the advent of monolithically fabricated transition edge sensor (TES) arrays, the number of on-sky detectors has been increasing exponentially for over a decade. The…
▽ More
Cosmic microwave background (CMB) measurements are fundamentally limited by photon statistics. Therefore, ground-based CMB observatories have been increasing the number of detectors that are simultaneously observing the sky. Thanks to the advent of monolithically fabricated transition edge sensor (TES) arrays, the number of on-sky detectors has been increasing exponentially for over a decade. The next-generation experiment CMB-S4 will increase this detector count by more than an order of magnitude from the current state-of-the-art to ~500,000. The readout of such a huge number of exquisitely precise sub-Kelvin sensors is feasible using an existing technology: frequency-domain multiplexing (fMux). To further optimize this system and reduce complexity and cost, we have recently made significant advances including the elimination of 4 K electronics, a massive decrease of parasitic in-series impedances, and a significant increase in multiplexing factor.
△ Less
Submitted 20 August, 2019;
originally announced August 2019.
-
Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
Authors:
Daniel Flanigan,
Bradley R. Johnson,
Maximilian H. Abitbol,
Sean Bryan,
Robin Cantor,
Peter K. Day,
Glenn Jones,
Philip Mauskopf,
Heather McCarrick,
Amber Miller,
Jonas Zmuidzinas
Abstract:
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a sli…
▽ More
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a slightly elevated critical temperature ($T_\mathrm{c} = 1.4 \, \mathrm{K}$), it therefore transitions before the package ($T_\mathrm{c} = 1.2 \, \mathrm{K}$), which also serves as a magnetic shield. On cooldown, ambient magnetic fields as small as approximately $30 \, \mathrm{μT}$ can produce vortices in the thin-film aluminum as it transitions because the bulk aluminum package has not yet transitioned and therefore is not yet shielding. These vortices become trapped inside the aluminum package below $1.2 \, \mathrm{K}$ and ultimately produce low internal quality factors in the thin-film superconducting resonators. We show that by controlling the strength of the magnetic field present when the thin film transitions, we can control the internal quality factor of the resonators. We also compare the noise performance with and without vortices present, and find no evidence for excess noise beyond the increase in amplifier noise, which is expected with increasing loss.
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
A Titanium Nitride Absorber for Controlling Optical Crosstalk in Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths
Authors:
H. McCarrick,
D. Flanigan,
G. Jones,
B. R. Johnson,
P. A. R. Ade,
K. Bradford,
S. Bryan,
R. Cantor,
G. Che,
P. Day,
S. Doyle,
H. Leduc,
M. Limon,
P. Mauskopf,
A. Miller,
T. Mroczkowski,
C. Tucker,
J. Zmuidzinas
Abstract:
We discuss the design and measured performance of a titanium nitride (TiN) mesh absorber we are developing for controlling optical crosstalk in horn-coupled lumped-element kinetic inductance detector arrays for millimeter-wavelengths. This absorber was added to the fused silica anti-reflection coating attached to previously-characterized, 20-element prototype arrays of LEKIDs fabricated from thin-…
▽ More
We discuss the design and measured performance of a titanium nitride (TiN) mesh absorber we are developing for controlling optical crosstalk in horn-coupled lumped-element kinetic inductance detector arrays for millimeter-wavelengths. This absorber was added to the fused silica anti-reflection coating attached to previously-characterized, 20-element prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon substrates. To test the TiN crosstalk absorber, we compared the measured response and noise properties of LEKID arrays with and without the TiN mesh. For this test, the LEKIDs were illuminated with an adjustable, incoherent electronic millimeter-wave source. Our measurements show that the optical crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on average, so the approach is effective and a viable candidate for future kilo-pixel arrays.
△ Less
Submitted 6 December, 2015;
originally announced December 2015.
-
Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
Authors:
Daniel Flanigan,
Heather McCarrick,
Glenn Jones,
Bradley R. Johnson,
Maximilian H. Abitbol,
Peter Ade,
Derek Araujo,
Kristi Bradford,
Robin Cantor,
George Che,
Peter K. Day,
Simon Doyle,
Carl Bjorn Kjellstrand,
Henry G LeDuc,
Michele Limon,
Vy Luu,
Philip Mauskopf,
Amber Miller,
Tony Mroczkowski,
Carole Tucker,
Jonas Zmuidzinas
Abstract:
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generato…
▽ More
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generator. We demonstrate that the detector response over a 40 dB range of source power is well-described by a simple model that considers the number of quasiparticles. The detector noise-equivalent power (NEP) is dominated by photon noise when the absorbed power is greater than approximately 1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \, \mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher source power levels we observe the relationships between noise and power expected from the photon statistics of the source signal: $\mathrm{NEP} \propto P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for continuous-wave (coherent) illumination.
△ Less
Submitted 24 May, 2017; v1 submitted 22 October, 2015;
originally announced October 2015.
-
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths
Authors:
H. McCarrick,
D. Flanigan,
G. Jones,
B. R. Johnson,
P. Ade,
D. Araujo,
K. Bradford,
R. Cantor,
G. Che,
P. Day,
S. Doyle,
H. Leduc,
M. Limon,
V. Luu,
P. Mauskopf,
A. Miller,
T. Mroczkowski,
C. Tucker,
J. Zmuidzinas
Abstract:
We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background (CMB) studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated twenty-element…
▽ More
We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background (CMB) studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated twenty-element arrays, optimized for a spectral band centered on 150 GHz, to test the sensitivity and yield of the devices as well as the multiplexing scheme. We characterized the detectors in two configurations. First, the detectors were tested in a dark environment with the horn apertures covered, and second, the horn apertures were pointed towards a beam-filling cryogenic blackbody load. These tests show that the multiplexing scheme is robust and scalable, the yield across multiple LEKID arrays is 91%, and the noise-equivalent temperatures (NET) for a 4 K optical load are in the range 26$\thinspace\pm6 \thinspace μ\mbox{K} \sqrt{\mbox{s}}$.
△ Less
Submitted 26 March, 2015; v1 submitted 29 July, 2014;
originally announced July 2014.
-
Optical NEP in Hot-Electron Nanobolometers
Authors:
Boris S. Karasik,
Robin Cantor
Abstract:
For the first time, we have measured the optical noise equivalent power (NEP) in titanium (Ti) superconducting hot-electron nanobolometers (nano-HEBs). The bolometers were 2μmx1μmx20nm and 1μmx1μmx20nm planar antenna-coupled devices. The measurements were done at λ = 460 μm using a cryogenic black body radiation source delivering optical power from a fraction of a femtowatt to a few 100s of femtow…
▽ More
For the first time, we have measured the optical noise equivalent power (NEP) in titanium (Ti) superconducting hot-electron nanobolometers (nano-HEBs). The bolometers were 2μmx1μmx20nm and 1μmx1μmx20nm planar antenna-coupled devices. The measurements were done at λ = 460 μm using a cryogenic black body radiation source delivering optical power from a fraction of a femtowatt to a few 100s of femtowatts. A record low NEP = 3x10^{-19} W/Hz^{1/2} at 50 mK has been achieved. This sensitivity meets the requirements for SAFARI instrument on the SPICA telescope. The ways for further improvement of the nano-HEB detector sensitivity are discussed.
△ Less
Submitted 23 September, 2010;
originally announced September 2010.