-
An improved analysis framework for axion dark matter searches
Authors:
D. A. Palken,
B. M. Brubaker,
M. Malnou,
S. Al Kenany,
K. M. Backes,
S. B. Cahn,
Y. V. Gurevich,
S. K. Lamoreaux,
S. M. Lewis,
R. H. Maruyama,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
K. van Bibber,
L. Zhong,
K. W. Lehnert
Abstract:
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis f…
▽ More
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.
△ Less
Submitted 28 July, 2020; v1 submitted 18 March, 2020;
originally announced March 2020.
-
Extending light WIMP searches to single scintillation photons in LUX
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
L. de Viveiros,
A. Dobi
, et al. (100 additional authors not shown)
Abstract:
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its…
▽ More
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
△ Less
Submitted 27 December, 2019; v1 submitted 14 July, 2019;
originally announced July 2019.
-
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in sea…
▽ More
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
△ Less
Submitted 3 September, 2017;
originally announced September 2017.
-
Recent Technical Improvements to the HAYSTAC Experiment
Authors:
L. Zhong,
B. M. Brubaker,
S. B. Cahn,
S. K. Lamoreaux
Abstract:
We report here several technical improvements to the HAYSTAC (Haloscope at Yale Sensitive To Axion Cold dark matter) that have improved operational efficiency, sensitivity, and stability.
We report here several technical improvements to the HAYSTAC (Haloscope at Yale Sensitive To Axion Cold dark matter) that have improved operational efficiency, sensitivity, and stability.
△ Less
Submitted 7 August, 2017; v1 submitted 12 June, 2017;
originally announced June 2017.
-
Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (75 additional authors not shown)
Abstract:
We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of…
▽ More
We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $σ_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($σ_p$ = 5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
△ Less
Submitted 23 June, 2017; v1 submitted 9 May, 2017;
originally announced May 2017.
-
First Searches for Axions and Axion-Like Particles with the LUX Experiment
Authors:
D. S. Akerib,
S. Alsum,
C. Aquino,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes…
▽ More
The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90% C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper limit in coupling corresponds to an upper limit on axion mass of 0.12 eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are excluded. For galactic axion-like particles, values of gAe larger than 4.2 $\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16 keV/c$^{2}$. These are the most stringent constraints to date for these interactions.
△ Less
Submitted 30 June, 2017; v1 submitted 7 April, 2017;
originally announced April 2017.
-
Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range
Authors:
S. Al Kenany,
M. A. Anil,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
I. Urdinaran,
K. A. van Bibber,
L. Zhong
Abstract:
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently comple…
▽ More
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.
△ Less
Submitted 22 February, 2017; v1 submitted 21 November, 2016;
originally announced November 2016.
-
First results from a microwave cavity axion search at 24 micro-eV
Authors:
B. M. Brubaker,
L. Zhong,
Y. V. Gurevich,
S. B. Cahn,
S. K. Lamoreaux,
M. Simanovskaia,
J. R. Root,
S. M. Lewis,
S. Al Kenany,
K. M. Backes,
I. Urdinaran,
N. M. Rapidis,
T. M. Shokair,
K. A. van Bibber,
D. A. Palken,
M. Malnou,
W. F. Kindel,
M. A. Anil,
K. W. Lehnert,
G. Carosi
Abstract:
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an orde…
▽ More
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.
△ Less
Submitted 9 February, 2017; v1 submitted 8 October, 2016;
originally announced October 2016.
-
Results from a search for dark matter in the complete LUX exposure
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high…
▽ More
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
△ Less
Submitted 13 January, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison
, et al. (82 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. T…
▽ More
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).
△ Less
Submitted 26 October, 2016; v1 submitted 18 August, 2016;
originally announced August 2016.
-
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (77 additional authors not shown)
Abstract:
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background…
▽ More
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $β$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
△ Less
Submitted 16 May, 2016; v1 submitted 10 December, 2015;
originally announced December 2015.
-
Tritium calibration of the LUX dark matter experiment
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (76 additional authors not shown)
Abstract:
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the resu…
▽ More
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a re-analysis of the LUX Run3 WIMP search.
△ Less
Submitted 5 May, 2016; v1 submitted 9 December, 2015;
originally announced December 2015.
-
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Authors:
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
T. Coffey,
A. Currie,
L. de Viveiros,
A. Dobi,
J. Dobson,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
C. Flores
, et al. (55 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The ex…
▽ More
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.
△ Less
Submitted 5 March, 2014;
originally announced March 2014.
-
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
Authors:
M. Szydagis,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
T. Coffey,
A. Currie,
L. de Viveiros,
A. Dobi,
J. Dobson,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci
, et al. (55 additional authors not shown)
Abstract:
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keV…
▽ More
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.
△ Less
Submitted 25 February, 2014; v1 submitted 15 February, 2014;
originally announced February 2014.
-
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
K. Clark,
T. Coffey,
A. Currie,
A. Curioni,
S. Dazeley,
L. de Viveiros,
A. Dobi
, et al. (78 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li…
▽ More
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
△ Less
Submitted 5 February, 2014; v1 submitted 30 October, 2013;
originally announced October 2013.
-
Technical Results from the Surface Run of the LUX Dark Matter Experiment
Authors:
LUX Collaboration,
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
J. J. Chapman,
T. Coffey,
A. Dobi,
E. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
M. Gilchriese,
C. Hall,
M. Hanhardt,
M. Ihm,
R. G. Jacobsen,
L. Kastens
, et al. (42 additional authors not shown)
Abstract:
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed i…
▽ More
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. We also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 22 February, 2013; v1 submitted 16 October, 2012;
originally announced October 2012.
-
An Ultra-Low Background PMT for Liquid Xenon Detectors
Authors:
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
Y-D. Chan,
K. Clark,
T. Coffey,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (42 additional authors not shown)
Abstract:
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other det…
▽ More
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
△ Less
Submitted 24 June, 2013; v1 submitted 10 May, 2012;
originally announced May 2012.
-
After LUX: The LZ Program
Authors:
D. C. Malling,
D. S. Akerib,
H. M. Araujo,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
T. Coffey,
A. Curioni,
A. Currie,
S. Dazeley,
L. de Viveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson
, et al. (49 additional authors not shown)
Abstract:
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In p…
▽ More
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.
△ Less
Submitted 13 October, 2011; v1 submitted 1 October, 2011;
originally announced October 2011.
-
Scintillation and charge extraction from the tracks of energetic electrons in superfluid helium-4
Authors:
W. Guo,
M. Dufault,
S. B. Cahn,
J. A. Nikkel,
Y. Shin,
D. N. McKinsey
Abstract:
An energetic electron passing through liquid helium causes ionization along its track. The ionized electrons quickly recombine with the resulting positive ions, which leads to the production of prompt scintillation light. By applying appropriate electric fields, some of the ionized electrons can be separated from their parent ions. The fraction of the ionized electrons extracted in a given applied…
▽ More
An energetic electron passing through liquid helium causes ionization along its track. The ionized electrons quickly recombine with the resulting positive ions, which leads to the production of prompt scintillation light. By applying appropriate electric fields, some of the ionized electrons can be separated from their parent ions. The fraction of the ionized electrons extracted in a given applied field depends on the separation distance between the electrons and the ions. We report the determination of the mean electron-ion separation distance for charge pairs produced along the tracks of beta particles in superfluid helium at 1.5 K by studying the quenching of the scintillation light under applied electric fields. Knowledge of this mean separation parameter will aid in the design of particle detectors that use superfluid helium as a target material.
△ Less
Submitted 26 September, 2011;
originally announced September 2011.
-
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
T. Coffey,
A. Curioni,
S. Dazeley,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook
, et al. (38 additional authors not shown)
Abstract:
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX exper…
▽ More
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This paper describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.
△ Less
Submitted 9 August, 2011; v1 submitted 8 August, 2011;
originally announced August 2011.
-
Calibration of liquid argon and neon detectors with $^{83}Kr^m$
Authors:
W. H. Lippincott,
S. B. Cahn,
D. Gastler,
L. W. Kastens,
E. Kearns,
D. N. McKinsey,
J. A. Nikkel
Abstract:
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$ scintillation peak at 41.5 keV appears in both liquids when filling our detector through a piece of zeolite coated with $^{83}$Rb. Based on this scintillation peak, we observe…
▽ More
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$ scintillation peak at 41.5 keV appears in both liquids when filling our detector through a piece of zeolite coated with $^{83}$Rb. Based on this scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a resolution of 6% ($σ$/E) and 3.0 photoelectrons/keV in liquid neon with a resolution of 19% ($σ$/E). The observed peak intensity subsequently decays with the $^{83}$Kr$^{\mathrm{m}}$ half-life after stopping the fill, and we find evidence that the spatial location of $^{83}$Kr$^{\mathrm{m}}$ atoms in the chamber can be resolved. $^{83}$Kr$^{\mathrm{m}}$ will be a useful calibration source for liquid argon and neon dark matter and solar neutrino detectors.
△ Less
Submitted 30 November, 2009;
originally announced November 2009.
-
Calibration of a Liquid Xenon Detector with Kr-83m
Authors:
L. W. Kastens,
S. B. Cahn,
A. Manzur,
D. N. McKinsey
Abstract:
We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid xenon. Decaying Kr-83m nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and 32.1 keV from the decay of K…
▽ More
We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid xenon. Decaying Kr-83m nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and 32.1 keV from the decay of Kr-83m were both observed. This calibration source will allow the characterization of the scintillation and ionization response of noble liquid detectors at low energies, highly valuable for the search for WIMP dark matter. Kr-83m may also be useful for measuring fluid flow dynamics, both to understand purification in noble liquid-based particle detectors, as well as for studies of classical and quantum turbulence in superfluid helium.
△ Less
Submitted 11 December, 2009; v1 submitted 12 May, 2009;
originally announced May 2009.
-
Detection and Imaging of He_2 Molecules in Superfluid Helium
Authors:
W. G. Rellergert,
S. B. Cahn,
A. Garvan,
J. C. Hanson,
W. H. Lippincott,
J. A. Nikkel,
D. N. McKinsey
Abstract:
We present data that show a cycling transition can be used to detect and image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate that limitations on the cycling efficiency due to the vibrational structure of the molecule can be mitigated by the use of repumping lasers. Images of the molecules obtained using the method are also shown. This technique gives rise to a new kind…
▽ More
We present data that show a cycling transition can be used to detect and image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate that limitations on the cycling efficiency due to the vibrational structure of the molecule can be mitigated by the use of repumping lasers. Images of the molecules obtained using the method are also shown. This technique gives rise to a new kind of ionizing radiation detector. The use of He$_2$ triplet molecules as tracer particles in the superfluid promises to be a powerful tool for visualization of both quantum and classical turbulence in liquid helium.
△ Less
Submitted 18 December, 2007; v1 submitted 12 September, 2007;
originally announced September 2007.