-
Evaluating the GeoSnap 13-$μ$m Cut-Off HgCdTe Detector for mid-IR ground-based astronomy
Authors:
Jarron M. Leisenring,
Dani Atkinson,
Rory Bowens,
Vincent Douence,
William F. Hoffmann,
Michael R. Meyer,
John Auyeung,
James Beletic,
Mario S. Cabrera,
Alexandra Z. Greenbaum,
Phil Hinz,
Derek Ives,
William J. Forrest,
Craig W. McMurtry,
Judith L. Pipher,
Eric Viges
Abstract:
New mid-infrared HgCdTe (MCT) detector arrays developed in collaboration with Teledyne Imaging Sensors (TIS) have paved the way for improved 10-$μ$m sensors for space- and ground-based observatories. Building on the successful development of longwave HAWAII-2RGs for space missions such as NEO Surveyor, we characterize the first 13-$μ$m GeoSnap detector manufactured to overcome the challenges of hi…
▽ More
New mid-infrared HgCdTe (MCT) detector arrays developed in collaboration with Teledyne Imaging Sensors (TIS) have paved the way for improved 10-$μ$m sensors for space- and ground-based observatories. Building on the successful development of longwave HAWAII-2RGs for space missions such as NEO Surveyor, we characterize the first 13-$μ$m GeoSnap detector manufactured to overcome the challenges of high background rates inherent in ground-based mid-IR astronomy. This test device merges the longwave HgCdTe photosensitive material with Teledyne's 2048x2048 GeoSnap-18 (18-$μ$m pixel) focal plane module, which is equipped with a capacitive transimpedance amplifier (CTIA) readout circuit paired with an onboard 14-bit analog-to-digital converter (ADC). The final assembly yields a mid-IR detector with high QE, fast readout (>85 Hz), large well depth (>1.2 million electrons), and linear readout.
Longwave GeoSnap arrays would ideally be deployed on existing ground-based telescopes as well as the next generation of extremely large telescopes. While employing advanced adaptive optics (AO) along with state-of-the-art diffraction suppression techniques, instruments utilizing these detectors could attain background- and diffraction-limited imaging at inner working angles <10 $λ/D$, providing improved contrast-limited performance compared to JWST MIRI while operating at comparable wavelengths. We describe the performance characteristics of the 13-$μ$m GeoSnap array operating between 38 and 45K, including quantum efficiency, well depth, linearity, gain, dark current, and frequency-dependent (1/f) noise profile.
△ Less
Submitted 17 July, 2023; v1 submitted 8 June, 2023;
originally announced June 2023.
-
Characterization of a 15 $μm$ Cutoff HgCdTe Detector Array for Astronomy
Authors:
Mario S. Cabrera,
Craig W. McMurtry,
William J. Forrest,
Judith L. Pipher,
Meghan L. Dorn,
Donald Lee
Abstract:
The University of Rochester infrared detector group is working together with Teledyne Imaging Sensors to develop HgCdTe 15 $μm$ cutoff wavelength detector arrays for future space missions. To reach the 15 $μm$ cutoff goal, we took an intermediate step by developing four $\sim$13 $μm$ cutoff wavelength arrays to identify any unforeseen effects related to increasing the cutoff wavelength from the ex…
▽ More
The University of Rochester infrared detector group is working together with Teledyne Imaging Sensors to develop HgCdTe 15 $μm$ cutoff wavelength detector arrays for future space missions. To reach the 15 $μm$ cutoff goal, we took an intermediate step by developing four $\sim$13 $μm$ cutoff wavelength arrays to identify any unforeseen effects related to increasing the cutoff wavelength from the extensively characterized 10 $μm$ cutoff wavelength detector arrays developed for the NEOCam mission. The characterization of the $\sim$13 $μm$ cutoff wavelength HgCdTe arrays at the University of Rochester allowed us to determine the key dark current mechanisms that limit the performance of these HgCdTe detector arrays at different temperatures and bias when the cutoff wavelength is increased. We present initial dark current and well depth measurements of a 15 $μm$ cutoff array which shows dark current values two orders of magnitude smaller at large reverse bias than would be expected from our previous best structures.
△ Less
Submitted 18 November, 2019;
originally announced November 2019.
-
Development of 13 $μm$ Cutoff HgCdTe Detector Arrays for Astronomy
Authors:
Mario S. Cabrera,
Craig W. McMurtry,
Meghan L. Dorn,
William J. Forrest,
Judith L. Pipher,
Donald Lee
Abstract:
Building on the successful development of the 10 $μm$ HgCdTe detector arrays for the proposed NEOCam mission, the University of Rochester Infrared Detector team and Teledyne Imaging Systems are working together to extend the cutoff wavelength of HgCdTe detector arrays initially to 13 $μm$, with the ultimate goal of developing 15 $μm$ HgCdTe detector arrays for space and ground-based astronomy. The…
▽ More
Building on the successful development of the 10 $μm$ HgCdTe detector arrays for the proposed NEOCam mission, the University of Rochester Infrared Detector team and Teledyne Imaging Systems are working together to extend the cutoff wavelength of HgCdTe detector arrays initially to 13 $μm$, with the ultimate goal of developing 15 $μm$ HgCdTe detector arrays for space and ground-based astronomy. The advantage of HgCdTe detector arrays is that they can operate at higher temperatures than the currently used arsenic doped silicon detector arrays at the longer wavelengths. Our infrared detector team at the University of Rochester has received and tested four 13 $μm$ detector arrays from Teledyne Imaging Systems with three different pixel designs, two of which are meant to reduce quantum tunneling dark current. The pixel design of one of these arrays has mitigated the effects of quantum tunneling dark currents for which we have been able to achieve, at a temperature of 28 K and applied bias of 350 mV, a well depth of at least 75 $ke^-$ for 90% of the pixels with a median dark current of 1.8 $e^-/sec$. These arrays have demonstrated encouraging results as we move forward to extending the cutoff wavelength to 15 $μm$.
△ Less
Submitted 3 September, 2019;
originally announced September 2019.
-
Preliminary Analysis of WISE/NEOWISE 3-Band Cryogenic and Post-Cryogenic Observations of Main Belt Asteroids
Authors:
Joseph R. Masiero,
A. K. Mainzer,
T. Grav,
J. M. Bauer,
R. M. Cutri,
C. Nugent,
M. S. Cabrera
Abstract:
We present preliminary diameters and albedos for 13511 MBAs that were observed during the 3-Band Cryo phase of the WISE survey (after the outer cryogen tank was exhausted) and as part of the NEOWISE Post-Cryo Survey (after the inner cryogen tank was exhausted). With a reduced or complete loss of sensitivity in the two long wavelength channels of WISE, the uncertainty in our fitted diameters and al…
▽ More
We present preliminary diameters and albedos for 13511 MBAs that were observed during the 3-Band Cryo phase of the WISE survey (after the outer cryogen tank was exhausted) and as part of the NEOWISE Post-Cryo Survey (after the inner cryogen tank was exhausted). With a reduced or complete loss of sensitivity in the two long wavelength channels of WISE, the uncertainty in our fitted diameters and albedos is increased to ~20% for diameter and ~40% for albedo. Diameter fits using only the 3.4 and 4.6 um channels are shown to be dependent on the literature optical H absolute magnitudes. These data allow us to increase the number of size estimates for large MBAs which have been identified as members of dynamical families. We present thermal fits for 14 asteroids previously identified as the parents of a dynamical family that were not observed during the fully cryogenic mission.
△ Less
Submitted 25 September, 2012;
originally announced September 2012.