Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
Authors:
The DEAP Collaboration,
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
D. J. Auty,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
J. M. Corning
, et al. (104 additional authors not shown)
Abstract:
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar…
▽ More
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors.
The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.
△ Less
Submitted 6 April, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector
Authors:
R. Ajaj,
G. R. Araujo,
M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
K. Dering,
F. A. Duncan,
M. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
D. Gallacher,
P. García Abia
, et al. (66 additional authors not shown)
Abstract:
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $β$ and…
▽ More
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $β$ and $γ$-rays originating from internal and external radioactivity in the detector material. A background model of the ER interactions in DEAP-3600 was developed and is described in this work. The model is based on several components which are expected from radioisotopes in the LAr, from ex-situ material assay measurements, and from dedicated independent in-situ analyses. This prior information is used in a Bayesian fit of the ER components to a 247.2 d dataset to model the radioactivity in the surrounding detector materials. While excellent discrimination between ERs and NRs is reached with pulse shape discrimination, utilizing the large difference between fast and slow components of LAr scintillation light, detailed knowledge of the ER background and activity of detector components, sets valuable constraints on other key types of backgrounds in the detector: neutrons and alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is determined by measuring the daughter decay of $^{42}$K. This cosmogenically activated trace isotope is a relevant background at higher energies for other rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND. The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm 5.9$ $μ$Bq/kg of argon.
△ Less
Submitted 14 May, 2019;
originally announced May 2019.
-
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
Authors:
R. Ajaj,
P. -A. Amaudruz,
G. R. Araujo,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
L. Doria,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are obs…
▽ More
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.
△ Less
Submitted 4 July, 2019; v1 submitted 11 February, 2019;
originally announced February 2019.
-
Design and Construction of the DEAP-3600 Dark Matter Detector
Authors:
P. -A. Amaudruz,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
S. Churchwell,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
S. Dittmeier,
F. A. Duncan
, et al. (84 additional authors not shown)
Abstract:
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a…
▽ More
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector.
△ Less
Submitted 10 April, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.
-
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Authors:
DEAP-3600 Collaboration,
:,
P. -A. Amaudruz,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
S. Dittmeier
, et al. (81 additional authors not shown)
Abstract:
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produ…
▽ More
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 tonne-days) of data taken with the nearly full detector during the initial filling phase demonstrates the detector performance and the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage $<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate signal events are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100 GeV/c$^2$ WIMP mass (90% C.L.).
△ Less
Submitted 13 August, 2018; v1 submitted 25 July, 2017;
originally announced July 2017.
-
DEAP-3600 Dark Matter Search
Authors:
DEAP Collaboration,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Chen,
R. Chouinard,
B. T. Cleveland,
K. Dering,
J. DiGioseffo,
F. Duncan,
T. Flower,
R. Ford,
P. Giampa,
P. Gorel,
K. Graham,
D. R. Grant,
E. Guliyev,
A. L. Hallin,
M. Hamstra
, et al. (32 additional authors not shown)
Abstract:
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds…
▽ More
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds and helped to develop low radioactivity techniques to mitigate surface-related $α$ backgrounds. Construction of the DEAP-3600 detector is nearly complete and commissioning is starting in 2014. The target sensitivity to spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons of 10$^{-46}$ cm$^2$ will allow one order of magnitude improvement in sensitivity over current searches at 100 GeV WIMP mass. This paper presents an overview and status of the DEAP-3600 project and discusses plans for a future multi-tonne experiment, DEAP-50T.
△ Less
Submitted 25 August, 2015; v1 submitted 27 October, 2014;
originally announced October 2014.
-
Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
J. Bonatt,
K. Boudjemline,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
F. Duncan,
N. Fatemighomi,
R. Ford,
R. Gagnon,
P. Giampa,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel
, et al. (47 additional authors not shown)
Abstract:
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be…
▽ More
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be $<1.4\times 10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil acceptance of at least 90%, with 4% systematic uncertainty on the absolute energy scale. The discrimination measurement on surface was limited by nuclear recoils induced by cosmic-ray generated neutrons. This was improved by moving the detector to the SNOLAB underground laboratory, where the reduced background rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the underground data set, is in the nuclear-recoil region of interest. Taking into account the expected background of 0.48 events coming from random pileup, the resulting upper limit on the electronic recoil contamination is $<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil acceptance of at least 90%, with 6% systematic uncertainty on the absolute energy scale.
We developed a general mathematical framework to describe PSD parameter distributions and used it to build an analytical model of the distributions observed in DEAP-1. Using this model, we project a misidentification fraction of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for a detector with 8 PE/keVee light yield. This reduction enables a search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming negligible contribution from nuclear recoil backgrounds.
△ Less
Submitted 14 September, 2016; v1 submitted 20 April, 2009;
originally announced April 2009.