-
Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
C. Goodman,
M. Guzzetti,
C. Hanretty,
S. Lee,
G. Leum,
L. J. Rosenberg,
G. Rybka,
J. Sinnis,
D. Zhang,
M. H. Awida,
D. Bowring,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
R. Khatiwada,
J. Brodsky,
G. Carosi,
L. D. Duffy
, et al. (31 additional authors not shown)
Abstract:
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion se…
▽ More
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
A Review of NEST Models, and Their Application to Improvement of Particle Identification in Liquid Xenon Experiments
Authors:
M. Szydagis,
J. Balajthy,
G. A. Block,
J. P. Brodsky,
E. Brown,
J. E. Cutter,
S. J. Farrell,
J. Huang,
E. S. Kozlova,
C. S. Liebenthal,
D. N. McKinsey,
K. McMichael,
M. Mooney,
J. Mueller,
K. Ni,
G. R. C. Rischbieter,
M. Tripathi,
C. D. Tunnell,
V. Velan,
M. D. Wyman,
Z. Zhao,
M. Zhong
Abstract:
This paper discusses microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event physics searches, and describes experimental observables useful to understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique, or NEST, which is a toolk…
▽ More
This paper discusses microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event physics searches, and describes experimental observables useful to understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique, or NEST, which is a toolkit based upon experimental data and simple, empirical formulae. NEST models of light and of charge production as a function of particle type, energy, and electric field are reviewed, as well as of energy resolution and final pulse areas. After vetting of NEST against raw data, with several specific examples pulled from XENON, ZEPLIN, LUX / LZ, and PandaX, we interpolate and extrapolate its models to draw new conclusions on the properties of future detectors (e.g., XLZD), in terms of the best possible discrimination of electronic recoil backgrounds from the potential nuclear recoil signal due to WIMP dark matter. We find that the oft-quoted value of a 99.5% discrimination is likely too conservative. NEST shows that another order of magnitude improvement (99.95% discrimination) may be achievable with a high photon detection efficiency (g1 about 15-20%) and reasonably achievable drift field of approximately 300 V/cm.
△ Less
Submitted 14 December, 2023; v1 submitted 19 November, 2022;
originally announced November 2022.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
Dark Sectors 2016 Workshop: Community Report
Authors:
Jim Alexander,
Marco Battaglieri,
Bertrand Echenard,
Rouven Essig,
Matthew Graham,
Eder Izaguirre,
John Jaros,
Gordan Krnjaic,
Jeremy Mardon,
David Morrissey,
Tim Nelson,
Maxim Perelstein,
Matt Pyle,
Adam Ritz,
Philip Schuster,
Brian Shuve,
Natalia Toro,
Richard G Van De Water,
Daniel Akerib,
Haipeng An,
Konrad Aniol,
Isaac J. Arnquist,
David M. Asner,
Henning O. Back,
Keith Baker
, et al. (179 additional authors not shown)
Abstract:
This report, based on the Dark Sectors workshop at SLAC in April 2016, summarizes the scientific importance of searches for dark sector dark matter and forces at masses beneath the weak-scale, the status of this broad international field, the important milestones motivating future exploration, and promising experimental opportunities to reach these milestones over the next 5-10 years.
This report, based on the Dark Sectors workshop at SLAC in April 2016, summarizes the scientific importance of searches for dark sector dark matter and forces at masses beneath the weak-scale, the status of this broad international field, the important milestones motivating future exploration, and promising experimental opportunities to reach these milestones over the next 5-10 years.
△ Less
Submitted 30 August, 2016;
originally announced August 2016.
-
IC at IC: IceCube can constrain the intrinsic charm of the proton
Authors:
Ranjan Laha,
Stanley J. Brodsky
Abstract:
The discovery of extraterrestrial neutrinos in the $\sim$ 30 TeV -- PeV energy range by IceCube provides new constraints on high energy astrophysics. An important background to the signal are the prompt neutrinos which originate from the decay of charm hadrons produced by high energy cosmic-ray particles interacting in the Earth's atmosphere. It is conventional to use the calculations of charm had…
▽ More
The discovery of extraterrestrial neutrinos in the $\sim$ 30 TeV -- PeV energy range by IceCube provides new constraints on high energy astrophysics. An important background to the signal are the prompt neutrinos which originate from the decay of charm hadrons produced by high energy cosmic-ray particles interacting in the Earth's atmosphere. It is conventional to use the calculations of charm hadroproduction using gluon splitting $g \to c \bar c$ alone. However, QCD predicts an additional "intrinsic" component of the heavy quark distribution which arises from diagrams where heavy quarks are multiply connected to the proton's valence quarks. We estimate the prompt neutrino spectrum due to intrinsic charm. We find that the atmospheric prompt neutrino flux from intrinsic charm is comparable to those calculated using QCD computations not including intrinsic charm, once we normalize the intrinsic charm differential cross sections to the ISR and the LEBC-MPS collaboration data. In future, IceCube will constrain the intrinsic charm content of the proton and will contribute to one of the major questions in high energy physics phenomenology.
△ Less
Submitted 7 December, 2017; v1 submitted 27 July, 2016;
originally announced July 2016.
-
Results from the first use of low radioactivity argon in a dark matter search
Authors:
The DarkSide Collaboration,
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello
, et al. (136 additional authors not shown)
Abstract:
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the La…
▽ More
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
△ Less
Submitted 13 April, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
The Electronics and Data Acquisition System of the DarkSide Dark Matter Search
Authors:
The DarkSide Collaboration,
P. Agnes,
T. Alexander,
A. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
A. Brigatti,
J. Brodsky,
F. Budano,
L. Cadonati,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
A. G. Cocco,
L. Crippa,
D. D'Angelo
, et al. (121 additional authors not shown)
Abstract:
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del…
▽ More
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three active, embedded components; an outer water veto (CTF), a liquid scintillator veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper describes the data acquisition and electronic systems of the DS detectors, designed to detect the residual ionization from such collisions.
△ Less
Submitted 22 January, 2015; v1 submitted 9 December, 2014;
originally announced December 2014.
-
First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
Authors:
P. Agnes,
T. Alexander,
A. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
A. Brigatti,
J. Brodsky,
F. Budano,
L. Cadonati,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
A. G. Cocco,
L. Crippa,
D. D'Angelo,
M. D'Incecco
, et al. (121 additional authors not shown)
Abstract:
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid sci…
▽ More
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid scintillator neutron veto, which is in turn installed at the center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We report here the null results of a dark matter search for a (1422+-67) kg d exposure with an atmospheric argon fill. This is the most sensitive dark matter search performed with an argon target, corresponding to a 90% CL upper limit on the WIMP-nucleon spin-independent cross section of 6.1x10^-44 cm^2 for a WIMP mass of 100 GeV/c^2.
△ Less
Submitted 27 February, 2015; v1 submitted 2 October, 2014;
originally announced October 2014.
-
Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for Dark Matter Searches
Authors:
T. Alexander,
D. Alton,
K. Arisaka,
H. O. Back,
P. Beltrame,
J. Benziger,
G. Bonfini,
A. Brigatti,
J. Brodsky,
L. Cadonati,
F. Calaprice,
A. Candela,
H. Cao,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
D. Cline,
A. G. Cocco,
C. Condon,
D. D'Angelo,
S. Davini,
E. De Haas,
A. Derbin,
G. Di Pietro,
I. Dratchnev
, et al. (97 additional authors not shown)
Abstract:
As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-r…
▽ More
As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-recoil backgrounds by pulse shape discrimination. We have measured the light yield of DarkSide-10 using the readily-identifiable full-absorption peaks from gamma ray sources combined with single-photoelectron calibrations using low-occupancy laser pulses. For gamma lines of energies in the range 122-1275 keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys) p.e./keVee. With additional purification, the light yield measured at 511 keV increased to 9.142+-0.006(stat) p.e./keVee.
△ Less
Submitted 14 August, 2013; v1 submitted 27 April, 2012;
originally announced April 2012.
-
Essence of the vacuum quark condensate
Authors:
Stanley J. Brodsky,
Craig D. Roberts,
Robert Shrock,
Peter C. Tandy
Abstract:
We show that the chiral-limit vacuum quark condensate is qualitatively equivalent to the pseudoscalar meson leptonic decay constant in the sense that they are both obtained as the chiral-limit value of well-defined gauge-invariant hadron-to-vacuum transition amplitudes that possess a spectral representation in terms of the current-quark mass. Thus, whereas it might sometimes be convenient to imagi…
▽ More
We show that the chiral-limit vacuum quark condensate is qualitatively equivalent to the pseudoscalar meson leptonic decay constant in the sense that they are both obtained as the chiral-limit value of well-defined gauge-invariant hadron-to-vacuum transition amplitudes that possess a spectral representation in terms of the current-quark mass. Thus, whereas it might sometimes be convenient to imagine otherwise, neither is essentially a constant mass-scale that fills all spacetime. This means, in particular, that the quark condensate can be understood as a property of hadrons themselves, which is expressed, for example, in their Bethe-Salpeter or light-front wavefunctions.
△ Less
Submitted 25 May, 2010;
originally announced May 2010.
-
Standard-Model Condensates and the Cosmological Constant
Authors:
Stanley J. Brodsky,
Robert Shrock
Abstract:
We suggest a solution to the problem of some apparently excessive contributions to the cosmological constant from Standard-Model condensates.
We suggest a solution to the problem of some apparently excessive contributions to the cosmological constant from Standard-Model condensates.
△ Less
Submitted 17 March, 2008;
originally announced March 2008.
-
On Condensates in Strongly Coupled Gauge Theories
Authors:
Stanley J. Brodsky,
Robert Shrock
Abstract:
We present a new perspective on the nature of quark and gluon condensates in quantum chromodynamics. We suggest that the spatial support of QCD condensates is restricted to the interiors of hadrons, since these condensates arise due to the interactions of confined quarks and gluons. An analogy is drawn with order parameters like the Cooper pair condensate and spontaneous magnetization experiment…
▽ More
We present a new perspective on the nature of quark and gluon condensates in quantum chromodynamics. We suggest that the spatial support of QCD condensates is restricted to the interiors of hadrons, since these condensates arise due to the interactions of confined quarks and gluons. An analogy is drawn with order parameters like the Cooper pair condensate and spontaneous magnetization experimentally measured in finite samples in condensed matter physics. Our picture explains the results of recent studies which find no significant signal for the vacuum gluon condensate. We also give a general discussion of condensates in asymptotically free vectorial and chiral gauge theories.
△ Less
Submitted 18 July, 2008; v1 submitted 17 March, 2008;
originally announced March 2008.