-
A Titanium Nitride Absorber for Controlling Optical Crosstalk in Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths
Authors:
H. McCarrick,
D. Flanigan,
G. Jones,
B. R. Johnson,
P. A. R. Ade,
K. Bradford,
S. Bryan,
R. Cantor,
G. Che,
P. Day,
S. Doyle,
H. Leduc,
M. Limon,
P. Mauskopf,
A. Miller,
T. Mroczkowski,
C. Tucker,
J. Zmuidzinas
Abstract:
We discuss the design and measured performance of a titanium nitride (TiN) mesh absorber we are developing for controlling optical crosstalk in horn-coupled lumped-element kinetic inductance detector arrays for millimeter-wavelengths. This absorber was added to the fused silica anti-reflection coating attached to previously-characterized, 20-element prototype arrays of LEKIDs fabricated from thin-…
▽ More
We discuss the design and measured performance of a titanium nitride (TiN) mesh absorber we are developing for controlling optical crosstalk in horn-coupled lumped-element kinetic inductance detector arrays for millimeter-wavelengths. This absorber was added to the fused silica anti-reflection coating attached to previously-characterized, 20-element prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon substrates. To test the TiN crosstalk absorber, we compared the measured response and noise properties of LEKID arrays with and without the TiN mesh. For this test, the LEKIDs were illuminated with an adjustable, incoherent electronic millimeter-wave source. Our measurements show that the optical crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on average, so the approach is effective and a viable candidate for future kilo-pixel arrays.
△ Less
Submitted 6 December, 2015;
originally announced December 2015.
-
Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
Authors:
Daniel Flanigan,
Heather McCarrick,
Glenn Jones,
Bradley R. Johnson,
Maximilian H. Abitbol,
Peter Ade,
Derek Araujo,
Kristi Bradford,
Robin Cantor,
George Che,
Peter K. Day,
Simon Doyle,
Carl Bjorn Kjellstrand,
Henry G LeDuc,
Michele Limon,
Vy Luu,
Philip Mauskopf,
Amber Miller,
Tony Mroczkowski,
Carole Tucker,
Jonas Zmuidzinas
Abstract:
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generato…
▽ More
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generator. We demonstrate that the detector response over a 40 dB range of source power is well-described by a simple model that considers the number of quasiparticles. The detector noise-equivalent power (NEP) is dominated by photon noise when the absorbed power is greater than approximately 1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \, \mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher source power levels we observe the relationships between noise and power expected from the photon statistics of the source signal: $\mathrm{NEP} \propto P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for continuous-wave (coherent) illumination.
△ Less
Submitted 24 May, 2017; v1 submitted 22 October, 2015;
originally announced October 2015.
-
Design of Dual-Polarization Horn-Coupled Kinetic Inductance Detectors for Cosmic Microwave Background Polarimetry
Authors:
Sean Bryan,
Kristi Bradford,
George Che,
Peter Day,
Daniel Flanigan,
Bradley R. Johnson,
Glenn Jones,
Bjorn Kjellstrand,
Michele Limon,
Philip Mauskopf,
Heather McCarrick,
Amber Miller,
Brian Smiley
Abstract:
Mapping the polarization of the Cosmic Microwave Background is yielding exciting data on the origin of the universe, the reionization of the universe, and the growth of cosmic structure. Kilopixel arrays represent the current state of the art, but advances in detector technology are needed to enable the larger detector arrays needed for future measurements. Here we present a design for single-band…
▽ More
Mapping the polarization of the Cosmic Microwave Background is yielding exciting data on the origin of the universe, the reionization of the universe, and the growth of cosmic structure. Kilopixel arrays represent the current state of the art, but advances in detector technology are needed to enable the larger detector arrays needed for future measurements. Here we present a design for single-band dual-polarization Kinetic Inductance Detectors (KIDs) at 20% bandwidths centered at 145, 220, and 280 GHz. The detection and readout system is nearly identical to the successful photon-noise-limited aluminum Lumped-Element KIDs that have been recently built and tested by some of the authors. Fabricating large focal plane arrays of the feed horns and quarter-wave backshorts requires only conventional precision machining. Since the detectors and readout lines consist only of a single patterned aluminum layer on a SOI wafer, arrays of the detectors can be built commercially or at a standard university cleanroom.
△ Less
Submitted 16 March, 2015;
originally announced March 2015.
-
BICEP2/Keck Array IV: Optical Characterization and Performance of the BICEP2 and Keck Array Experiments
Authors:
The BICEP2,
Keck Array Collaborations,
:,
P. A. R. Ade,
R. W. Aikin,
D. Barkats,
S. J. Benton,
C. A. Bischoff,
J. J. Bock,
K. J. Bradford,
J. A. Brevik,
I. Buder,
E. Bullock,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
S. R. Hildebrandt,
G. C. Hilton,
H. Hui,
K. D. Irwin,
J. H. Kang
, et al. (29 additional authors not shown)
Abstract:
BICEP2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. BICEP2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolomet…
▽ More
BICEP2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. BICEP2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). BICEP2 and the Keck Array share a common optical design and employ the field-proven BICEP1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of BICEP2 and the Keck Array at 150 GHz.
△ Less
Submitted 21 July, 2015; v1 submitted 2 February, 2015;
originally announced February 2015.
-
The Next Generation BLAST Experiment
Authors:
Nicholas Galitzki,
Peter A. R. Ade,
Francesco E. Angilè,
Peter Ashton,
James A. Beall,
Dan Becker,
Kristi J. Bradford,
George Che,
Hsiao-Mei Cho,
Mark J. Devlin,
Bradley J. Dober,
Laura M. Fissel,
Yasuo Fukui,
Jiansong Gao,
Christopher E. Groppi,
Seth Hillbrand,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Jeffrey Klein,
Jeff Van Lanen,
Dale Li,
Zhi-Yun Li,
Nathan P. Lourie,
Hamdi Mani
, et al. (16 additional authors not shown)
Abstract:
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol) was a suborbital experiment designed to map magnetic fields in order to study their role in star formation processes. BLASTPol made detailed polarization maps of a number of molecular clouds during its successful flights from Antarctica in 2010 and 2012. We present the next-generation BLASTPol instrument (BLAST-TNG…
▽ More
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol) was a suborbital experiment designed to map magnetic fields in order to study their role in star formation processes. BLASTPol made detailed polarization maps of a number of molecular clouds during its successful flights from Antarctica in 2010 and 2012. We present the next-generation BLASTPol instrument (BLAST-TNG) that will build off the success of the previous experiment and continue its role as a unique instrument and a test bed for new technologies. With a 16-fold increase in mapping speed, BLAST-TNG will make larger and deeper maps. Major improvements include a 2.5 m carbon fiber mirror that is 40% wider than the BLASTPol mirror and ~3000 polarization sensitive detectors. BLAST-TNG will observe in three bands at 250, 350, and 500 microns. The telescope will serve as a pathfinder project for microwave kinetic inductance detector (MKID) technology, as applied to feedhorn coupled submillimeter detector arrays. The liquid helium cooled cryostat will have a 28-day hold time and will utilize a closed-cycle $^3$He refrigerator to cool the detector arrays to 270 mK. This will enable a detailed mapping of more targets with higher polarization resolution than any other submillimeter experiment to date. BLAST-TNG will also be the first balloon-borne telescope to offer shared risk observing time to the community. This paper outlines the motivation for the project and the instrumental design.
△ Less
Submitted 12 November, 2014; v1 submitted 24 September, 2014;
originally announced September 2014.
-
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths
Authors:
H. McCarrick,
D. Flanigan,
G. Jones,
B. R. Johnson,
P. Ade,
D. Araujo,
K. Bradford,
R. Cantor,
G. Che,
P. Day,
S. Doyle,
H. Leduc,
M. Limon,
V. Luu,
P. Mauskopf,
A. Miller,
T. Mroczkowski,
C. Tucker,
J. Zmuidzinas
Abstract:
We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background (CMB) studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated twenty-element…
▽ More
We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background (CMB) studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated twenty-element arrays, optimized for a spectral band centered on 150 GHz, to test the sensitivity and yield of the devices as well as the multiplexing scheme. We characterized the detectors in two configurations. First, the detectors were tested in a dark environment with the horn apertures covered, and second, the horn apertures were pointed towards a beam-filling cryogenic blackbody load. These tests show that the multiplexing scheme is robust and scalable, the yield across multiple LEKID arrays is 91%, and the noise-equivalent temperatures (NET) for a 4 K optical load are in the range 26$\thinspace\pm6 \thinspace μ\mbox{K} \sqrt{\mbox{s}}$.
△ Less
Submitted 26 March, 2015; v1 submitted 29 July, 2014;
originally announced July 2014.
-
A LEKID-based CMB instrument design for large-scale observations in Greenland
Authors:
D. C. Araujo,
P. A. R. Ade,
J. R. Bond,
K. J. Bradford,
D. Chapman,
G. Che,
P. K. Day,
J. Didier,
S. Doyle,
H. K. Eriksen,
D. Flanigan,
C. E. Groppi,
S. N. Hillbrand,
B. R. Johnson,
G. Jones,
M. Limon,
A. D. Miller,
P. Mauskopf,
H. McCarrick,
T. Mroczkowski,
B. Reichborn-Kjennerud,
B. Smiley,
J. Sobrin,
I. K. Wehus,
J. Zmuidzinas
Abstract:
We present the results of a feasibility study, which examined deployment of a ground-based millimeter-wave polarimeter, tailored for observing the cosmic microwave background (CMB), to Isi Station in Greenland. The instrument for this study is based on lumped-element kinetic inductance detectors (LEKIDs) and an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The telescope is mou…
▽ More
We present the results of a feasibility study, which examined deployment of a ground-based millimeter-wave polarimeter, tailored for observing the cosmic microwave background (CMB), to Isi Station in Greenland. The instrument for this study is based on lumped-element kinetic inductance detectors (LEKIDs) and an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The telescope is mounted inside the receiver and cooled to $<\,4$ K by a closed-cycle $^4$He refrigerator to reduce background loading on the detectors. Linearly polarized signals from the sky are modulated with a metal-mesh half-wave plate that is rotated at the aperture stop of the telescope with a hollow-shaft motor based on a superconducting magnetic bearing. The modular detector array design includes at least 2300 LEKIDs, and it can be configured for spectral bands centered on 150~GHz or greater. Our study considered configurations for observing in spectral bands centered on 150, 210 and 267~GHz. The entire polarimeter is mounted on a commercial precision rotary air bearing, which allows fast azimuth scan speeds with negligible vibration and mechanical wear over time. A slip ring provides power to the instrument, enabling circular scans (360 degrees of continuous rotation). This mount, when combined with sky rotation and the latitude of the observation site, produces a hypotrochoid scan pattern, which yields excellent cross-linking and enables 34\% of the sky to be observed using a range of constant elevation scans. This scan pattern and sky coverage combined with the beam size (15~arcmin at 150~GHz) makes the instrument sensitive to $5 < \ell < 1000$ in the angular power spectra.
△ Less
Submitted 10 October, 2014; v1 submitted 10 July, 2014;
originally announced July 2014.
-
The next-generation BLASTPol experiment
Authors:
Bradley Dober,
Peter A. R. Ade,
Peter Ashton,
Francesco E. Angilè,
James A. Beall,
Dan Becker,
Kristi J. Bradford,
George Che,
Hsiao-Mei Cho,
Mark J. Devlin,
Laura M. Fissel,
Yasuo Fukui,
Nicholas Galitzki,
Jiansong Gao,
Christopher E. Groppi,
Seth Hillbrand,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Jeffrey Klein,
Jeff Van Lanen,
Dale Li,
Zhi-Yun Li,
Nathan P. Lourie,
Hamdi Mani
, et al. (14 additional authors not shown)
Abstract:
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol) is a suborbital mapping experiment designed to study the role magnetic fields play in star formation. BLASTPol has had two science flights from McMurdo Station, Antarctica in 2010 and 2012. These flights have produced thousands of polarization vectors at 250, 350 and 500 microns in several molecular cloud targets.…
▽ More
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol) is a suborbital mapping experiment designed to study the role magnetic fields play in star formation. BLASTPol has had two science flights from McMurdo Station, Antarctica in 2010 and 2012. These flights have produced thousands of polarization vectors at 250, 350 and 500 microns in several molecular cloud targets. We present the design, specifications, and progress towards the next-generation BLASTPol experiment (BLAST-TNG). BLAST-TNG will fly a 40% larger diameter primary mirror, with almost 8 times the number of polarization-sensitive detectors resulting in a factor of 16 increase in mapping speed. With a spatial resolution of 22 arcseconds and four times the field of view of BLASTPol, BLAST-TNG will bridge the angular scales between Planck's low resolution all-sky maps and ALMA's ultra-high resolution narrow fields. The new receiver has a larger cryogenics volume, allowing for a 28 day hold time. BLAST-TNG employs three arrays of Microwave Kinetic Inductance Detectors (MKIDs) with 30% fractional bandwidth at 250, 350 and 500 microns. In this paper, we will present the new BLAST-TNG instrument and science objectives.
△ Less
Submitted 14 July, 2014;
originally announced July 2014.
-
The Detector System for the Stratospheric Kinetic Inductance Polarimeter (SKIP)
Authors:
B. R. Johnson,
P. A. R. Ade,
D. Araujo,
K. J. Bradford,
D. Chapman,
P. K. Day,
J. Didier,
S. Doyle,
H. K. Eriksen,
D. Flanigan,
C. Groppi,
S. Hillbrand,
G. Jones,
M. Limon,
P. Mauskopf,
H. McCarrick,
A. Miller,
T. Mroczkowski,
B. Reichborn-Kjennerud,
B. Smiley,
J. Sobrin,
I. K. Wehus,
J. Zmuidzinas
Abstract:
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kineti…
▽ More
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be maintained at 100 mK with an adiabatic demagnetization refrigerator. The polarimeter operates in two configurations, one sensitive to a spectral band centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The detector readout system is based on the ROACH-1 board, and the detectors will be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To minimize detector loading and maximize sensitivity, the entire optical system will be cooled to 1 K. Linearly polarized sky signals will be modulated with a metal-mesh half-wave plate that is mounted at the telescope aperture and rotated by a superconducting magnetic bearing. The observation program consists of at least two, five-day flights beginning with the 150 GHz observations.
△ Less
Submitted 5 January, 2014; v1 submitted 1 August, 2013;
originally announced August 2013.
-
Optical Characterization of the Keck Array Polarimeter at the South Pole
Authors:
A. G. Vieregg,
P. A. R. Ade,
R. Aikin,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
K. J. Bradford,
J. A. Brevik,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. S. Gordon,
M. Halpern,
G. Hilton,
V. V. Hristov,
K. Irwin,
S. Kernasovskiy,
J. M. Kovac,
C. L. Kuo,
E. Leitch,
M. Lueker,
T. Montroy,
C. B. Netterfield
, et al. (15 additional authors not shown)
Abstract:
The Keck Array (SPUD) is a set of microwave polarimeters that observes from the South Pole at degree angular scales in search of a signature of Inflation imprinted as B-mode polarization in the Cosmic Microwave Background (CMB). The first three Keck Array receivers were deployed during the 2010-2011 Austral summer, followed by two new receivers in the 2011-2012 summer season, completing the full f…
▽ More
The Keck Array (SPUD) is a set of microwave polarimeters that observes from the South Pole at degree angular scales in search of a signature of Inflation imprinted as B-mode polarization in the Cosmic Microwave Background (CMB). The first three Keck Array receivers were deployed during the 2010-2011 Austral summer, followed by two new receivers in the 2011-2012 summer season, completing the full five-receiver array. All five receivers are currently observing at 150 GHz. The Keck Array employs the field-proven BICEP/BICEP2 strategy of using small, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. We describe our efforts to characterize the main beam shape and beam shape mismatch between co-located orthogonally-polarized detector pairs, and discuss the implications of measured differential beam parameters on temperature to polarization leakage in CMB analysis.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.