-
HERMES: Gamma Ray Burst and Gravitational Wave counterpart hunter
Authors:
G. Ghirlanda,
L. Nava,
O. Salafia,
F. Fiore,
R. Campana,
R. Salvaterra,
A. Sanna,
W. Leone,
Y. Evangelista,
G. Dilillo,
S. Puccetti,
A. Santangelo,
M. Trenti,
A. Guzmán,
P. Hedderman,
G. Amelino-Camelia,
M. Barbera,
G. Baroni,
M. Bechini,
P. Bellutti,
G. Bertuccio,
G. Borghi,
A. Brandonisio,
L. Burderi,
C. Cabras
, et al. (45 additional authors not shown)
Abstract:
Gamma Ray Bursts (GRBs) bridge relativistic astrophysics and multi-messenger astronomy. Space-based gamma/X-ray wide field detectors have proven essential to detect and localize the highly variable GRB prompt emission, which is also a counterpart of gravitational wave events. We study the capabilities to detect long and short GRBs by the High Energy Rapid Modular Ensemble of Satellites (HERMES) Pa…
▽ More
Gamma Ray Bursts (GRBs) bridge relativistic astrophysics and multi-messenger astronomy. Space-based gamma/X-ray wide field detectors have proven essential to detect and localize the highly variable GRB prompt emission, which is also a counterpart of gravitational wave events. We study the capabilities to detect long and short GRBs by the High Energy Rapid Modular Ensemble of Satellites (HERMES) Pathfinder (HP) and SpIRIT, namely a swarm of six 3U CubeSats to be launched in early 2025, and a 6U CubeSat launched on December 1st 2023. We also study the capabilities of two advanced configurations of swarms of >8 satellites with improved detector performances (HERMES Constellations). The HERMES detectors, sensitive down to ~2-3 keV, will be able to detect faint/soft GRBs which comprise X-ray flashes and high redshift bursts. By combining state-of-the-art long and short GRB population models with a description of the single module performance, we estimate that HP will detect ~195^{+22}_{-21} long GRBs (3.4^{+0.3}_{-0.8} at redshift z>6) and ~19^{+5}_{-3} short GRBs per year. The larger HERMES Constellations under study can detect between ~1300 and ~3000 long GRBs per year and between ~160 and ~400 short GRBs per year, depending on the chosen configuration, with a rate of long GRBs above z>6 between 30 and 75 per year. Finally, we explore the capabilities of HERMES to detect short GRBs as electromagnetic counterparts of binary neutron star (BNS) mergers detected as gravitational signals by current and future ground-based interferometers. Under the assumption that the GRB jets are structured, we estimate that HP can provide up to 1 (14) yr^{-1} joint detections during the fifth LIGO-Virgo-KAGRA observing run (Einstein Telescope single triangle 10 km arm configuration). These numbers become 4 (100) yr^{-1}, respectively, for the HERMES Constellation configuration.
△ Less
Submitted 27 May, 2024;
originally announced May 2024.
-
The X/Gamma-ray Imaging Spectrometer (XGIS) on-board THESEUS: design, main characteristics, and concept of operation
Authors:
Claudio Labanti,
Lorenzo Amati,
Filippo Frontera,
Sandro Mereghetti,
José Luis Gasent-Blesa,
Christoph Tenzer,
Piotr Orleanski,
Irfan Kuvvetli,
Riccardo Campana,
Fabio Fuschino,
Luca Terenzi,
Enrico Virgilli,
Gianluca Morgante,
Mauro Orlandini,
Reginald C. Butler,
John B. Stephen,
Natalia Auricchio,
Adriano De Rosa,
Vanni Da Ronco,
Federico Evangelisti,
Michele Melchiorri,
Stefano Squerzanti,
Mauro Fiorini,
Giuseppe Bertuccio,
Filippo Mele
, et al. (36 additional authors not shown)
Abstract:
THESEUS is one of the three missions selected by ESA as fifth medium class mission (M5) candidates in its Cosmic Vision science program, currently under assessment in a phase A study with a planned launch date in 2032. THESEUS is designed to carry on-board two wide and deep sky monitoring instruments for X/gamma-ray transients detection: a wide-field soft X-ray monitor with imaging capability (Sof…
▽ More
THESEUS is one of the three missions selected by ESA as fifth medium class mission (M5) candidates in its Cosmic Vision science program, currently under assessment in a phase A study with a planned launch date in 2032. THESEUS is designed to carry on-board two wide and deep sky monitoring instruments for X/gamma-ray transients detection: a wide-field soft X-ray monitor with imaging capability (Soft X-ray Imager, SXI, 0.3 - 5 keV), a hard X-ray, partially-imaging spectroscopic instrument (X and Gamma Imaging Spectrometer, XGIS, 2 keV - 10 MeV), and an optical/near-IR telescope with both imaging and spectroscopic capability (InfraRed Telescope, IRT, 0.7 - 1.8 $μ$m). The spacecraft will be capable of performing fast repointing of the IRT to the error region provided by the monitors, thus allowing it to detect and localize the transient sources down to a few arcsec accuracy, for immediate identification and redshift determination. The prime goal of the XGIS will be to detect transient sources, with monitoring timescales down to milliseconds, both independently of, or following, up SXI detections, and identify the sources performing localisation at < 15 arcmin and characterize them over a broad energy band, thus providing also unique clues to their emission physics. The XGIS system consists of two independent but identical coded mask cameras, arranged to cover 2 steradians . The XGIS will exploit an innovative technology coupling Silicon Drift Detectors (SDD) with crystal scintillator bars and a very low-noise distributed front-end electronics (ORION ASICs), which will produce a position sensitive detection plane, with a large effective area over a huge energy band (from soft X-rays to soft gamma-rays) with timing resolution down to a few $μ$s.Here is presented an overview of the XGIS instrument design, its configuration, and capabilities.
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
The XGIS instrument on-board THESEUS: the detection plane and on-board electronics
Authors:
Fabio Fuschino,
Riccardo Campana,
Claudio Labanti,
Lorenzo Amati,
Enrico Virgilli,
Luca Terenzi,
Pierluigi Bellutti,
Giuseppe Bertuccio,
Giacomo Borghi,
Francesco Ficorella,
Massimo Gandola,
Marco Grassi,
Giovanni La Rosa,
Paolo Lorenzi,
Piero Malcovati,
Filippo Mele,
Piotr Orleański,
Antonino Picciotto,
Alexandre Rachevski,
Irina Rashevskaya,
Andrea Santangelo,
Paolo Sarra,
Giuseppe Sottile,
Christoph Tenzer,
Andrea Vacchi
, et al. (10 additional authors not shown)
Abstract:
The X and Gamma Imaging Spectrometer instrument on-board the THESEUS mission (selected by ESA in the framework of the Cosmic Vision M5 launch opportunity, currently in phase A) is based on a detection plane composed of several thousands of single active elements. Each element comprises a 4.5x4.5x30 mm 3 CsI(Tl) scintillator bar, optically coupled at both ends to Silicon Drift Detectors (SDDs). The…
▽ More
The X and Gamma Imaging Spectrometer instrument on-board the THESEUS mission (selected by ESA in the framework of the Cosmic Vision M5 launch opportunity, currently in phase A) is based on a detection plane composed of several thousands of single active elements. Each element comprises a 4.5x4.5x30 mm 3 CsI(Tl) scintillator bar, optically coupled at both ends to Silicon Drift Detectors (SDDs). The SDDs acts both as photodetectors for the scintillation light and as direct X-ray sensors. In this paper the design of the XGIS detection plane is reviewed, outlining the strategic choices in terms of modularity and redundancy of the system. Results on detector-electronics prototypes are also described. Moreover, the design and development of the low-noise front-end electronics is presented, emphasizing the innovative architectural design based on custom-designed Application-Specific Integrated Circuits (ASICs).
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
An innovative architecture for a wide band transient monitor on board the HERMES nano-satellite constellation
Authors:
F. Fuschino,
R. Campana,
C. Labanti,
Y. Evangelista,
F. Fiore,
M. Gandola,
M. Grassi,
F. Mele,
F. Ambrosino,
F. Ceraudo,
E. Demenev,
M. Fiorini,
G. Morgante,
R. Piazzolla,
G. Bertuccio,
P. Malcovati,
P. Bellutti,
G. Borghi,
G. Dilillo,
M. Feroci,
F. Ficorella,
G. La Rosa,
P. Nogara,
G. Pauletta,
A. Picciotto
, et al. (13 additional authors not shown)
Abstract:
The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich" concept, in which custom-designed, low-noise Silicon Drift Detectors are used to simultaneously detect soft X-rays and to readout the optical light produced by th…
▽ More
The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich" concept, in which custom-designed, low-noise Silicon Drift Detectors are used to simultaneously detect soft X-rays and to readout the optical light produced by the interaction of higher energy photons in GAGG:Ce scintillators. To preserve the inherent excellent spectroscopic performances of SDDs, advanced readout electronics is necessary. In this paper, the HERMES detector architecture concept will be described in detail, as well as the specifically developed front-end ASICs (LYRA-FE and LYRA-BE) and integration solutions. The experimental performance of the integrated system composed by scintillator+SDD+LYRA ASIC will be discussed, demonstrating that the requirements of a wide energy range sensitivity, from 2 keV up to 2 MeV, are met in a compact instrument.
△ Less
Submitted 8 January, 2021;
originally announced January 2021.
-
The enhanced X-ray Timing and Polarimetry mission - eXTP
Authors:
ShuangNan Zhang,
Andrea Santangelo,
Marco Feroci,
YuPeng Xu,
FangJun Lu,
Yong Chen,
Hua Feng,
Shu Zhang,
Søren Brandt,
Margarita Hernanz,
Luca Baldini,
Enrico Bozzo,
Riccardo Campana,
Alessandra De Rosa,
YongWei Dong,
Yuri Evangelista,
Vladimir Karas,
Norbert Meidinger,
Aline Meuris,
Kirpal Nandra,
Teng Pan,
Giovanni Pareschi,
Piotr Orleanski,
QiuShi Huang,
Stephane Schanne
, et al. (125 additional authors not shown)
Abstract:
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In ad…
▽ More
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
HERMES: An ultra-wide band X and gamma-ray transient monitor on board a nano-satellite constellation
Authors:
F. Fuschino,
R. Campana,
C. Labanti,
Y. Evangelista,
M. Feroci,
L. Burderi,
F. Fiore,
F. Ambrosino,
G. Baldazzi,
P. Bellutti,
R. Bertacin,
G. Bertuccio,
G. Borghi,
D. Cirrincione,
D. Cauz,
T. Di Salvo,
F. Ficorella,
M. Fiorini,
A. Gambino,
M. Gandola,
M. Grassi,
A. Guzman,
R. Iaria,
G. La Rosa,
M. Lavagna
, et al. (27 additional authors not shown)
Abstract:
The High Energy Modular Ensemble of Satellites (HERMES) project is aimed to realize a modular X/gamma-ray monitor for transient events, to be placed on-board of a CubeSat bus. This expandable platform will achieve a significant impact on Gamma Ray Burst (GRB) science and on the detection of Gravitational Wave (GW) electromagnetic counterparts: the recent LIGO/VIRGO discoveries demonstrated that th…
▽ More
The High Energy Modular Ensemble of Satellites (HERMES) project is aimed to realize a modular X/gamma-ray monitor for transient events, to be placed on-board of a CubeSat bus. This expandable platform will achieve a significant impact on Gamma Ray Burst (GRB) science and on the detection of Gravitational Wave (GW) electromagnetic counterparts: the recent LIGO/VIRGO discoveries demonstrated that the high-energy transient sky is still a field of extreme interest. The very complex temporal variability of GRBs (up to the millisecond scale) combined with the spatial and temporal coincidence between GWs and their electromagnetic counterparts suggest that upcoming instruments require sub-ms time resolution combined with a transient localization accuracy lower than a degree. The current phase of the ongoing HERMES project is focused on the realization of a technological pathfinder with a small network (3 units) of nano-satellites to be launched in mid 2020. We will show the potential and prospects for short and medium-term development of the project, demonstrating the disrupting possibilities for scientific investigations provided by the innovative concept of a new "modular astronomy" with nano-satellites (e.g. low developing costs, very short realization time). Finally, we will illustrate the characteristics of the HERMES Technological Pathfinder project, demonstrating how the scientific goals discussed are actually already reachable with the first nano-satellites of this constellation. The detector architecture will be described in detail, showing that the new generation of scintillators (e.g. GAGG:Ce) coupled with very performing Silicon Drift Detectors (SDD) and low noise Front-End-Electronics (FEE) are able to extend down to few keV the sensitivity band of the detector. The technical solutions for FEE, Back-End-Electronics (BEE) and Data Handling will be also described.
△ Less
Submitted 11 December, 2018; v1 submitted 6 December, 2018;
originally announced December 2018.
-
Characterization of a novel pixelated Silicon Drift Detector (PixDD) for high-throughput X-ray astrophysics
Authors:
Y. Evangelista,
F. Ambrosino,
M. Feroci,
P. Bellutti,
G. Bertuccio,
G. Borghi,
R. Campana,
M. Caselle,
D. Cirrincione,
F. Ficorella,
M. Fiorini,
F. Fuschino,
M. Gandola,
M. Grassi,
C. Labanti,
P. Malcovati,
F. Mele,
A. Morbidini,
A. Picciotto,
A. Rachevski,
I. Rashevskaya,
M. Sammartini,
G. Zampa,
N. Zampa,
N. Zorzi
, et al. (1 additional authors not shown)
Abstract:
Multi-pixel fast silicon detectors represent the enabling technology for the next generation of space-borne experiments devoted to high-resolution spectral-timing studies of low-flux compact cosmic sources. Several imaging detectors based on frame-integration have been developed as focal plane devices for X-ray space-borne missions but, when coupled to large-area concentrator X-ray optics, these d…
▽ More
Multi-pixel fast silicon detectors represent the enabling technology for the next generation of space-borne experiments devoted to high-resolution spectral-timing studies of low-flux compact cosmic sources. Several imaging detectors based on frame-integration have been developed as focal plane devices for X-ray space-borne missions but, when coupled to large-area concentrator X-ray optics, these detectors are affected by strong pile-up and dead-time effects, thus limiting the time and energy resolution as well as the overall system sensitivity. The current technological gap in the capability to realize pixelated silicon detectors for soft X-rays with fast, photon-by-photon response and nearly Fano-limited energy resolution therefore translates into the unavailability of sparse read-out sensors suitable for high throughput X-ray astronomy applications. In the framework of the ReDSoX Italian collaboration, we developed a new, sparse read-out, pixelated silicon drift detector which operates in the energy range 0.5-15 keV with nearly Fano-limited energy resolution ($\leq$150 eV FWHM @ 6 keV) at room temperature or with moderate cooling ($\sim$0 °C to +20 °C). In this paper, we present the design and the laboratory characterization of the first 16-pixel (4$\times$4) drift detector prototype (PixDD), read-out by individual ultra low-noise charge sensitive preamplifiers (SIRIO) and we discuss the future PixDD prototype developments.
△ Less
Submitted 29 August, 2018; v1 submitted 24 August, 2018;
originally announced August 2018.
-
The Large Area Detector onboard the eXTP mission
Authors:
Marco Feroci,
Mahdi Ahangarianabhari,
Giovanni Ambrosi,
Filippo Ambrosino,
Andrea Argan,
Marco Barbera,
Joerg Bayer,
Pierluigi Bellutti,
Bruna Bertucci,
Giuseppe Bertuccio,
Giacomo Borghi,
Enrico Bozzo,
Franck Cadoux,
Riccardo Campana,
Francesco Ceraudo,
Tianxiang Chen,
Daniela Cirrincione,
Alessandra De Rosa,
Ettore Del Monte,
Sergio Di Cosimo,
Sebastian Diebold,
Yuri Evangelista,
Qingmei Fan,
Yannick Favre,
Francesco Ficorella
, et al. (46 additional authors not shown)
Abstract:
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Det…
▽ More
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Detector and Wide Field Monitor) offering unprecedented simultaneous wide-band X-ray spectral, timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study and it is expected to provide key hardware elements, including a Large Area Detector (LAD). The LAD instrument for eXTP is based on the design originally proposed for the LOFT mission within the ESA context. The eXTP/LAD envisages a deployed 3.4 m2 effective area in the 2-30 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors - offering a spectral resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators - limiting the field of view to about 1 degree. In this paper we provide an overview of the LAD instrument design, including new elements with respect to the earlier LOFT configuration.
△ Less
Submitted 30 July, 2018;
originally announced July 2018.
-
The Wide Field Monitor onboard the eXTP mission
Authors:
M. Hernanz,
S. Brandt,
M. Feroci,
P. Orleanski,
A. Santangelo,
S. Schanne,
Xin Wu,
J. in't Zand,
S. N. Zhang,
Y. P. Xu,
E. Bozzo,
Y. Evangelista,
J. L. Gálvez,
C. Tenzer,
F. Zwart,
F. J. Lu,
S. Zhang,
T. X. Chen,
F. Ambrosino,
A. Argan,
E. Del Monte,
C. Budtz-Jørgensen,
N. Lund,
P. Olsen,
C. Mansanet
, et al. (15 additional authors not shown)
Abstract:
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Det…
▽ More
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Detector and Wide Field Monitor) offering unprecedented simultaneous wide-band X-ray timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study and it is expected to provide key hardware elements, including a Wide Field Monitor (WFM). The WFM instrument for eXTP is based on the design originally proposed for the LOFT mission within the ESA context. The eXTP/WFM envisages a wide field X-ray monitor system in the 2-50 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors. The WFM will consist of 3 pairs of coded mask cameras with a total combined Field of View (FoV) of 90x180 degrees at zero response and a source localization accuracy of ~1 arcmin. In this paper we provide an overview of the WFM instrument design, including new elements with respect to the earlier LOFT configuration, and anticipated performance.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
The X-Gamma Imaging Spectrometer (XGIS) onboard THESEUS
Authors:
R. Campana,
F. Fuschino,
C. Labanti,
L. Amati,
S. Mereghetti,
M. Fiorini,
F. Frontera,
G. Baldazzi,
P. Bellutti,
G. Borghi,
I. Elmi,
Y. Evangelista,
M. Feroci,
F. Ficorella,
M. Orlandini,
A. Picciotto,
M. Marisaldi,
A. Rachevski,
M. Uslenghi,
A. Vacchi,
G. Zampa,
N. Zampa,
N. Zorzi
Abstract:
A compact and modular X and gamma-ray imaging spectrometer (XGIS) has been designed as one of the instruments foreseen on-board the THESEUS mission proposed in response to the ESA M5 call. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm 2 Silicon Drift Detectors. Events absorbed in the Silicon layer (lower energy X rays) and events absorbed in t…
▽ More
A compact and modular X and gamma-ray imaging spectrometer (XGIS) has been designed as one of the instruments foreseen on-board the THESEUS mission proposed in response to the ESA M5 call. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm 2 Silicon Drift Detectors. Events absorbed in the Silicon layer (lower energy X rays) and events absorbed in the scintillator crystal (higher energy X rays and Gamma-rays) are discriminated using the on-board electronics. A coded mask provides imaging capabilities at low energies, thus allowing a compact and sensitive instrument in a wide energy band (~2 keV up to ~20 MeV). The instrument design, expected performance and the characterization performed on a series of laboratory prototypes are discussed.
△ Less
Submitted 5 February, 2018;
originally announced February 2018.
-
Angular resolution measurements at SPring-8 of a hard X-ray optic for the New Hard X-ray Mission
Authors:
D. Spiga,
L. Raimondi,
A. Furuzawa,
S. Basso,
R. Binda,
G. Borghi,
V. Cotroneo,
G. Grisoni,
H. Kunieda,
F. Marioni,
H. Matsumoto,
H. Mori,
T. Miyazawa,
B. Negri,
A. Orlandi,
G. Pareschi,
B. Salmaso,
G. Tagliaferri,
K. Uesugi,
G. Valsecchi,
D. Vernani
Abstract:
The realization of X-ray telescopes with imaging capabilities in the hard (> 10 keV) X-ray band requires the adoption of optics with shallow (< 0.25 deg) grazing angles to enhance the reflectivity of reflective coatings. On the other hand, to obtain large collecting area, large mirror diameters (< 350 mm) are necessary. This implies that mirrors with focal lengths >10 m shall be produced and teste…
▽ More
The realization of X-ray telescopes with imaging capabilities in the hard (> 10 keV) X-ray band requires the adoption of optics with shallow (< 0.25 deg) grazing angles to enhance the reflectivity of reflective coatings. On the other hand, to obtain large collecting area, large mirror diameters (< 350 mm) are necessary. This implies that mirrors with focal lengths >10 m shall be produced and tested. Full-illumination tests of such mirrors are usually performed with on- ground X-ray facilities, aimed at measuring their effective area and the angular resolution; however, they in general suffer from effects of the finite distance of the X-ray source, e.g. a loss of effective area for double reflection. These effects increase with the focal length of the mirror under test; hence a "partial" full-illumination measurement might not be fully representative of the in-flight performances. Indeed, a pencil beam test can be adopted to overcome this shortcoming, because a sector at a time is exposed to the X-ray flux, and the compensation of the beam divergence is achieved by tilting the optic. In this work we present the result of a hard X-ray test campaign performed at the BL20B2 beamline of the SPring-8 synchrotron radiation facility, aimed at characterizing the Point Spread Function (PSF) of a multilayer-coated Wolter-I mirror shell manufactured by Nickel electroforming. The mirror shell is a demonstrator for the NHXM hard X-ray imaging telescope (0.3 - 80 keV), with a predicted HEW (Half Energy Width) close to 20 arcsec. We show some reconstructed PSFs at monochromatic X-ray energies of 15 to 63 keV, and compare them with the PSFs computed from post-campaign metrology data, self-consistently treating profile and roughness data by means of a method based on the Fresnel diffraction theory. The modeling matches the measured PSFs accurately.
△ Less
Submitted 11 September, 2015;
originally announced September 2015.
-
Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study
Authors:
G. Tagliaferri,
S. Basso,
G. Borghi,
W. Burkert,
O. Citterio,
M. Civitani,
P. Conconi,
V. Cotroneo,
M. Freyberg,
D. Garoli,
P. Gorenstein,
G. Hartner,
V. Mattarello,
A. Orlandi,
G. Pareschi,
S. Romaine,
D. Spiga,
G. Valsecchi,
D. Vernani
Abstract:
Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical develop…
▽ More
Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission; ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV; iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.
△ Less
Submitted 13 March, 2009;
originally announced March 2009.