Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays
Authors:
M. A. Leutenegger,
M. E. Eckart,
S. J. Moseley,
S. O. Rohrbach,
J. K. Black,
M. P. Chiao,
R. L. Kelley,
C. A. Kilbourne,
F. S. Porter
Abstract:
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the…
▽ More
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals which are aligned in a dispersive configuration to select the \kaone line of the x-ray tube anode material. The entire device, including x-ray tube, can be easily hand carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100-200 $μ$m for the x-ray tubes used here), and is unfocused in the cross-dispersion direction, so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi Soft X-ray Spectrometer, which had 819 $μ$m square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs) which have effective theoretical FWHM energy resolution of 0.125, 0.197, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our \crkaone monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.
△ Less
Submitted 13 August, 2020;
originally announced August 2020.
-
Performance of the PRAXyS X-ray Polarimeter
Authors:
W. B. Iwakiri,
J. K. Black,
R. Cole,
T. Enoto,
A. Hayato,
J. E. Hill,
K. Jahoda,
P. Kaaret,
T. Kitaguchi,
M. Kubota,
H. Marlowe,
R. McCurdy,
Y. Takeuchi,
T. Tamagawa
Abstract:
The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven N…
▽ More
The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.
△ Less
Submitted 21 October, 2016;
originally announced October 2016.
-
Photoelectron track length distributions measured in a negative ion time projection chamber
Authors:
Z. R. Prieskorn,
J. E. Hill,
P. E. Kaaret,
J. K. Black
Abstract:
We report photoelectron track length distributions between 3 and 8 keV in gas mixtures of Ne+CO2+CH3NO2 (260:80:10 Torr) and CO2+CH3NO2 (197.5: 15 Torr). The measurements were made using a negative ion time projection chamber (NITPC) at the National Synchrotron Light Source (NSLS) at the Brookhaven National Laboratory (BNL). We report the first quantitative analysis of photoelectron track length d…
▽ More
We report photoelectron track length distributions between 3 and 8 keV in gas mixtures of Ne+CO2+CH3NO2 (260:80:10 Torr) and CO2+CH3NO2 (197.5: 15 Torr). The measurements were made using a negative ion time projection chamber (NITPC) at the National Synchrotron Light Source (NSLS) at the Brookhaven National Laboratory (BNL). We report the first quantitative analysis of photoelectron track length distributions in a gas. The distribution of track lengths at a given energy is best fit by a lognormal distribution. A powerlaw distribution of the form, f(E)=a(E/Eo)n, is found to fit the relationship between mean track length and energy. We find n=1.29 +/- 0.07 for Ne+CO2+CH3NO2 and n=1.20 +/- 0.09 for CO2+CH3NO2. Understanding the distribution of photoelectron track lengths in proportional counter gases is important for optimizing the pixel size and the dimensions of the active region in electron-drift time projection chambers (TPCs) and NITPC X-ray polarimeters.
△ Less
Submitted 17 June, 2014;
originally announced June 2014.
-
Gas Gain Measurements from a Negative Ion TPC X-ray Polarimeter
Authors:
Z. Prieskorn,
J. E. Hill,
P. E. Kaaret,
J. K. Black,
K. Jahoda
Abstract:
Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray emission of a Gamma-ray burst (GRB), a large area detector is needed. Diffusion of the electron cloud in a standard TPC could be prohibitive to measuring good mo…
▽ More
Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray emission of a Gamma-ray burst (GRB), a large area detector is needed. Diffusion of the electron cloud in a standard TPC could be prohibitive to measuring good modulation when the drift distance is large. Therefore, we propose using a negative ion TPC (NITPC) with Nitromethane (CH3NO2) as the electron capture agent. The diffusion of negative ions is reduced over that of electrons due to the thermal coupling of the negative ions to the surrounding gas. This allows for larger area detectors as the drift distance can be increased without degrading polarimeter modulation. Negative ions also travel ~200 times slower than electrons, allowing the readout electronics to operate slower, resulting in a reduction of instrument power. To optimize the NITPC design, we have measured gas gain with SciEnergy gas electron multipliers (GEMs) in single and double GEM configurations. Each setup was tested with different gas combinations, concentrations and pressures: P10 700 Torr, Ne+CO2 700 Torr at varying concentrations of CO2 and Ne+CO2+CH3NO2 700 Torr. We report gain as a function of total voltage, measured from top to bottom of the GEM stack, and as a function of drift field strength for the gas concentrations listed above. Examples of photoelectron tracks at 5.9 keV are also presented.
△ Less
Submitted 5 August, 2013; v1 submitted 15 July, 2011;
originally announced July 2011.
-
POET: POlarimeters for Energetic Transients
Authors:
J. E. Hill,
M. L. McConnell,
P. Bloser,
J. Legere,
J. Macri,
J. Ryan,
S. Barthelmy,
L. Angelini,
T. Sakamoto,
J. K. Black,
D. H. Hartmann,
P. Kaaret,
B. Zhang,
K. Ioka,
T. Nakamura,
K. Toma,
R. Yamazaki,
X. Wu
Abstract:
POET (Polarimeters for Energetic Transients) is a Small Explorer mission concept proposed to NASA in January 2008. The principal scientific goal of POET is to measure GRB polarization between 2 and 500 keV. The payload consists of two wide FoV instruments: a Low Energy Polarimeter (LEP) capable of polarization measurements in the energy range from 2-15 keV and a high energy polarimeter (Gamma-Ra…
▽ More
POET (Polarimeters for Energetic Transients) is a Small Explorer mission concept proposed to NASA in January 2008. The principal scientific goal of POET is to measure GRB polarization between 2 and 500 keV. The payload consists of two wide FoV instruments: a Low Energy Polarimeter (LEP) capable of polarization measurements in the energy range from 2-15 keV and a high energy polarimeter (Gamma-Ray Polarimeter Experiment -- GRAPE) that will measure polarization in the 60-500 keV energy range. Spectra will be measured from 2 keV up to 1 MeV. The POET spacecraft provides a zenith-pointed platform for maximizing the exposure to deep space. Spacecraft rotation will provide a means of effectively dealing with systematics in the polarization response. POET will provide sufficient sensitivity and sky coverage to measure statistically significant polarization for up to 100 GRBs in a two-year mission. Polarization data will also be obtained for solar flares, pulsars and other sources of astronomical interest.
△ Less
Submitted 14 October, 2008;
originally announced October 2008.
-
The imaging X-ray detector for Lobster-ISS
Authors:
J. K. Black,
A. N. Brunton,
N. P. Bannister,
P. Deines-Jones,
K. Jahoda
Abstract:
Lobster-ISS is a revolutionary astrophysical X-ray all-sky monitor scheduled for deployment as an attached payload on the International Space Station (ISS) in 2009. Using a new wide field-of-view focusing optic, Lobster-ISS provides an order-of-magnitude improvement in the sensitivity of all-sky monitors in the soft X-ray band (0.1-3.0 keV). This lobster-eye optic presents unique challenges to t…
▽ More
Lobster-ISS is a revolutionary astrophysical X-ray all-sky monitor scheduled for deployment as an attached payload on the International Space Station (ISS) in 2009. Using a new wide field-of-view focusing optic, Lobster-ISS provides an order-of-magnitude improvement in the sensitivity of all-sky monitors in the soft X-ray band (0.1-3.0 keV). This lobster-eye optic presents unique challenges to the imaging X-ray detector at its focus. Micro-patterned imaging proportional counters, with thier mechanical simplicity and high performance, are the most practical means of meeting the requirements. We describe our design for the Lobster-ISS imaging detector based on direct-imaging micro-well proportional counters and the expected performance.
△ Less
Submitted 7 May, 2003;
originally announced May 2003.
-
X-ray polarimetry with an active-matrix pixel proportional counter
Authors:
J. K. Black,
P. Deines-Jones,
S. E. Ready,
R. A. Street
Abstract:
We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/- 0.03, confirming previous reports of the high polarization sensitivity of a finely segmented pixel proportional counter. The detector described here has a geometry suit…
▽ More
We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/- 0.03, confirming previous reports of the high polarization sensitivity of a finely segmented pixel proportional counter. The detector described here has a geometry suitable for the focal plane of an astronomical X-ray telescope. Amorphous silicon readout technology will enable additional extensions and improvements.
△ Less
Submitted 27 March, 2003;
originally announced March 2003.