-
Radiopurity of a kg-scale PbWO$_4$ cryogenic detector produced from archaeological Pb for the RES-NOVA experiment
Authors:
J. W. Beeman,
G. Benato,
C. Bucci,
L. Canonica,
P. Carniti,
E. Celi,
M. Clemenza,
A. D'Addabbo,
F. A. Danevich,
S. Di Domizio,
S. Di Lorenzo,
O. M. Dubovik,
N. Ferreiro Iachellini,
F. Ferroni,
E. Fiorini,
S. Fu,
A. Garai,
S. Ghislandi,
L. Gironi,
P. Gorla,
C. Gotti,
P. V. Guillaumon,
D. L. Helis,
G. P. Kovtun,
M. Mancuso
, et al. (19 additional authors not shown)
Abstract:
RES-NOVA is a newly proposed experiment for the detection of neutrinos from astrophysical sources, mainly Supernovae, using an array of cryogenic detectors made of PbWO$_4$ crystals produced from archaeological Pb. This unconventional material, characterized by intrinsic high radiopurity, enables to achieve low-background levels in the region of interest for the neutrino detection via Coherent Ela…
▽ More
RES-NOVA is a newly proposed experiment for the detection of neutrinos from astrophysical sources, mainly Supernovae, using an array of cryogenic detectors made of PbWO$_4$ crystals produced from archaeological Pb. This unconventional material, characterized by intrinsic high radiopurity, enables to achieve low-background levels in the region of interest for the neutrino detection via Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS). This signal lies at the detector energy threshold, O(1 keV), and it is expected to be hidden by naturally occurring radioactive contaminants of the crystal absorber. Here, we present the results of a radiopurity assay on a 0.84 kg PbWO$_4$ crystal produced from archaeological Pb operated as a cryogenic detector. The crystal internal radioactive contaminations are: $^{232}$Th $<$40 $μ$Bq/kg, $^{238}$U $<$30 $μ$Bq/kg, $^{226}$Ra 1.3 mBq/kg and $^{210}$Pb 22.5 mBq/kg. We present also a background projection for the final experiment and possible mitigation strategies for further background suppression. The achieved results demonstrate the feasibility of realizing this new class of detectors.
△ Less
Submitted 28 March, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Search for axioelectric effect of solar axions using BGO scintillating bolometer
Authors:
A. V. Derbin,
L. Gironi,
S. S. Nagorny,
L. Pattavina,
J. W. Beeman,
F. Bellini,
M. Biassoni,
S. Capelli,
M. Clemenza,
I. S. Drachnev,
E. Ferri,
A. Giachero,
C. Gotti,
A. S. Kayunov,
C. Maiano,
M. Maino,
V. N. Muratova,
M. Pavan,
S. Pirro,
M. Sisti,
D. A. Semenov,
E. V. Unzhakov
Abstract:
A search for axioelectric absorption of solar axions produced in the $ p + d \rightarrow {^3\rm{He}}+γ~(5.5~ \rm{MeV})$ reactions has been performed with a BGO detector placed in a low-background setup. A model-independent limit on an axion-nucleon and axion-electron coupling constant has been obtained: $| g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90% confidence level. The constrains of the…
▽ More
A search for axioelectric absorption of solar axions produced in the $ p + d \rightarrow {^3\rm{He}}+γ~(5.5~ \rm{MeV})$ reactions has been performed with a BGO detector placed in a low-background setup. A model-independent limit on an axion-nucleon and axion-electron coupling constant has been obtained: $| g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90% confidence level. The constrains of the axion-electron coupling have been obtained for hadronic axion with masses in (0.1 - 1) MeV range: $|g_{Ae}| \leq (0.96 - 8.2)\times 10^{-8}$.
△ Less
Submitted 8 September, 2014; v1 submitted 15 May, 2014;
originally announced May 2014.
-
The Large APEX Bolometer Camera LABOCA
Authors:
G. Siringo,
E. Kreysa,
A. Kovacs,
F. Schuller,
A. Weiss,
W. Esch,
H. P. Gemuend,
N. Jethava,
G. Lundershausen,
A. Colin,
R. Guesten,
K. M. Menten,
A. Beelen,
F. Bertoldi,
J. W. Beeman,
E. E. Haller
Abstract:
The Large APEX Bolometer Camera, LABOCA, has been commissioned for operation as a new facility instrument t the Atacama Pathfinder Experiment 12m submillimeter telescope. This new 295-bolometer total power camera, operating in the 870 micron atmospheric window, combined with the high efficiency of APEX and the excellent atmospheric transmission at the site, offers unprecedented capability in map…
▽ More
The Large APEX Bolometer Camera, LABOCA, has been commissioned for operation as a new facility instrument t the Atacama Pathfinder Experiment 12m submillimeter telescope. This new 295-bolometer total power camera, operating in the 870 micron atmospheric window, combined with the high efficiency of APEX and the excellent atmospheric transmission at the site, offers unprecedented capability in mapping submillimeter continuum emission for a wide range of astronomical purposes.
△ Less
Submitted 7 March, 2009;
originally announced March 2009.
-
Debris disks around Sun-like stars
Authors:
D. E. Trilling,
G. Bryden,
C. A. Beichman,
G. H. Rieke,
K. Y. L. Su,
J. A. Stansberry,
M. Blaylock,
K. R. Stapelfeldt,
J. W. Beeman,
E. E. Haller
Abstract:
We have observed nearly 200 FGK stars at 24 and 70 microns with the Spitzer Space Telescope. We identify excess infrared emission, including a number of cases where the observed flux is more than 10 times brighter than the predicted photospheric flux, and interpret these signatures as evidence of debris disks in those systems. We combine this sample of FGK stars with similar published results to…
▽ More
We have observed nearly 200 FGK stars at 24 and 70 microns with the Spitzer Space Telescope. We identify excess infrared emission, including a number of cases where the observed flux is more than 10 times brighter than the predicted photospheric flux, and interpret these signatures as evidence of debris disks in those systems. We combine this sample of FGK stars with similar published results to produce a sample of more than 350 main sequence AFGKM stars. The incidence of debris disks is 4.2% (+2.0/-1.1) at 24 microns for a sample of 213 Sun-like (FG) stars and 16.4% (+2.8/-2.9) at 70 microns for 225 Sun-like (FG) stars. We find that the excess rates for A, F, G, and K stars are statistically indistinguishable, but with a suggestion of decreasing excess rate toward the later spectral types; this may be an age effect. The lack of strong trend among FGK stars of comparable ages is surprising, given the factor of 50 change in stellar luminosity across this spectral range. We also find that the incidence of debris disks declines very slowly beyond ages of 1 billion years.
△ Less
Submitted 29 October, 2007;
originally announced October 2007.
-
Absolute Calibration and Characterization of the Multiband Imaging Photometer for Spitzer. III. An Asteroid-based Calibration of MIPS at 160 microns
Authors:
J. A. Stansberry,
K. D. Gordon,
B. Bhattacharya,
C. W. Engelbracht,
G. H. Rieke,
F. R. Marleau,
D. Fadda,
D. T. Frayer,
A. Noriega-Crespo,
S. Wachter,
E. T. Young,
T. G. Mueller,
D. M. Kelly,
M. Blaylock,
D. Henderson,
G. Neugebauer,
J. W. Beeman,
E. E. Haller
Abstract:
We describe the absolute calibration of the Multiband Imaging Photometer for Spitzer (MIPS) 160 micron channel. After the on-orbit discovery of a near-IR ghost image that dominates the signal for sources hotter than about 2000 K, we adopted a strategy utilizing asteroids to transfer the absolute calibrations of the MIPS 24 and 70 micron channels to the 160 micron channel. Near-simultaneous obser…
▽ More
We describe the absolute calibration of the Multiband Imaging Photometer for Spitzer (MIPS) 160 micron channel. After the on-orbit discovery of a near-IR ghost image that dominates the signal for sources hotter than about 2000 K, we adopted a strategy utilizing asteroids to transfer the absolute calibrations of the MIPS 24 and 70 micron channels to the 160 micron channel. Near-simultaneous observations at all three wavelengths are taken, and photometry at the two shorter wavelengths is fit using the Standard Thermal Model. The 160 micron flux density is predicted from those fits and compared with the observed 160 micron signal to derive the conversion from instrumental units to surface brightness. The calibration factor we derive is 41.7 MJy/sr/MIPS160 (MIPS160 being the instrumental units). The scatter in the individual measurements of the calibration factor, as well as an assesment of the external uncertainties inherent in the calibration, lead us to adopt an uncertainty of 5.0 MJy/sr/MIPS160 (12%) for the absolute uncertainty on the 160 micron flux density of a particular source as determined from a single measurement. For sources brighter than about 2 Jy, non-linearity in the response of the 160 micron detectors produces an under-estimate of the flux density: for objects as bright as 4 Jy, measured flux densities are likely to be ~20% too low. This calibration has been checked against that of ISO (using ULIRGS) and IRAS (using IRAS-derived diameters), and is consistent with those at the 5% level.
△ Less
Submitted 24 July, 2007; v1 submitted 16 July, 2007;
originally announced July 2007.
-
16 x 25 Ge:Ga Detector Arrays for FIFI LS
Authors:
D. Rosenthal,
J. W. Beeman,
N. Geis,
L. Looney,
A. Poglitsch,
W. K. Park,
W. Raab,
A. Urban
Abstract:
We are developing two-dimensional 16 x 25 pixel detector arrays of both unstressed and stressed Ge:Ga photoconductive detectors for far-infrared astronomy from SOFIA. The arrays, based on earlier 5 x 5 detector arrays used on the KAO, will be for our new instrument, the Far Infrared Field Imaging Line Spectrometer (FIFI LS). The unstressed Ge:Ga detector array will cover the wavelength range fro…
▽ More
We are developing two-dimensional 16 x 25 pixel detector arrays of both unstressed and stressed Ge:Ga photoconductive detectors for far-infrared astronomy from SOFIA. The arrays, based on earlier 5 x 5 detector arrays used on the KAO, will be for our new instrument, the Far Infrared Field Imaging Line Spectrometer (FIFI LS). The unstressed Ge:Ga detector array will cover the wavelength range from 40 to 120 microns, and the stressed Ge:Ga detector array from 120 to 210 microns. The detector arrays will be operated with multiplexed integrating amplifiers with cryogenic readout electronics located close to the detector arrays. The design of the stressed detector array and results of current measurements on several prototype 16 pixel linear arrays are reported. They demonstrate the feasibility of the current concept. ***This paper does not include Figures due to astro-ph size limitations. Please download entire file at http://fifi-ls.mpe-garching.mpg.de/spie.det.ps.gz ***
△ Less
Submitted 23 March, 2000;
originally announced March 2000.