The CRESST II Dark Matter Search
Authors:
Leo Stodolsky,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
C. Bucci,
C. Ciemniak,
G. Deuter,
F. v. Feilitzsch,
D. Hauff,
P. Huff,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
J. C. Lanfranchi,
S. Pfister,
F. Petricca,
W. Potzel,
F. Proebst,
F. Reindl,
S. Roth,
K. Rottler,
C. Sailer,
K. Schaeffner
, et al. (11 additional authors not shown)
Abstract:
Direct Dark Matter detection with cryodetectors is briefly discussed, with particular mention of the possibility of the identification of the recoil nucleus. Preliminary results from the CREEST II Dark Matter search, with 730 kg-days of data, are presented. Major backgrounds and methods of identifying and dealing with them are indicated.
Direct Dark Matter detection with cryodetectors is briefly discussed, with particular mention of the possibility of the identification of the recoil nucleus. Preliminary results from the CREEST II Dark Matter search, with 730 kg-days of data, are presented. Major backgrounds and methods of identifying and dealing with them are indicated.
△ Less
Submitted 30 March, 2012;
originally announced March 2012.
-
Results from 730 kg days of the CRESST-II Dark Matter Search
Authors:
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
C. Bucci,
C. Ciemniak,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
P. Huff,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
J. -C. Lanfranchi,
F. Petricca,
S. Pfister,
W. Potzel,
F. Pröbst,
F. Reindl,
S. Roth,
K. Rottler,
C. Sailer,
K. Schäffner,
J. Schmaler
, et al. (11 additional authors not shown)
Abstract:
The CRESST-II cryogenic Dark Matter search, aiming at detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals, completed 730 kg days of data taking in 2011. We present the data collected with eight detector modules, each with a two-channel readout; one for a phonon signal and the other for coincidently produced scintillation light. The former provides a precise measure of the ene…
▽ More
The CRESST-II cryogenic Dark Matter search, aiming at detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals, completed 730 kg days of data taking in 2011. We present the data collected with eight detector modules, each with a two-channel readout; one for a phonon signal and the other for coincidently produced scintillation light. The former provides a precise measure of the energy deposited by an interaction, and the ratio of scintillation light to deposited energy can be used to discriminate different types of interacting particles and thus to distinguish possible signal events from the dominant backgrounds. Sixty-seven events are found in the acceptance region where a WIMP signal in the form of low energy nuclear recoils would be expected. We estimate background contributions to this observation from four sources: 1) "leakage" from the e/γ-band 2) "leakage" from the α-particle band 3) neutrons and 4) Pb-206 recoils from Po-210 decay. Using a maximum likelihood analysis, we find, at a high statistical significance, that these sources alone are not sufficient to explain the data. The addition of a signal due to scattering of relatively light WIMPs could account for this discrepancy, and we determine the associated WIMP parameters.
△ Less
Submitted 4 September, 2011;
originally announced September 2011.
-
Status of the CRESST Dark Matter Search
Authors:
J. Schmaler,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
R. F. Lang,
M. Malek,
R. McGowan
, et al. (16 additional authors not shown)
Abstract:
The CRESST experiment aims for a detection of dark matter in the form of WIMPs. These particles are expected to scatter elastically off the nuclei of a target material, thereby depositing energy on the recoiling nucleus. CRESST uses scintillating CaWO4 crystals as such a target. The energy deposited by an interacting particle is primarily converted to phonons which are detected by transition edg…
▽ More
The CRESST experiment aims for a detection of dark matter in the form of WIMPs. These particles are expected to scatter elastically off the nuclei of a target material, thereby depositing energy on the recoiling nucleus. CRESST uses scintillating CaWO4 crystals as such a target. The energy deposited by an interacting particle is primarily converted to phonons which are detected by transition edge sensors. In addition, a small fraction of the interaction energy is emitted from the crystals in the form of scintillation light which is measured in coincidence with the phonon signal by a separate cryogenic light detector for each target crystal. The ratio of light to phonon energy permits the discrimination between the nuclear recoils expected from WIMPs and events from radioactive backgrounds which primarily lead to electron recoils. CRESST has shown the success of this method in a commissioning run in 2007 and, since then, further investigated possibilities for an even better suppression of backgrounds. Here, we report on a new class of background events observed in the course of this work. The consequences of this observation are discussed and we present the current status of the experiment.
△ Less
Submitted 18 December, 2009;
originally announced December 2009.
-
Composite CaWO4 Detectors for the CRESST-II Experiment
Authors:
M. Kiefer,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
R. F. Lang,
M. Malek,
R. McGowan,
V. B. Mikhailik
, et al. (16 additional authors not shown)
Abstract:
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of…
▽ More
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber crystal. The process of evaporation causes a decrease in the scintillation light output. This, together with the need of a big-scale detector production for the upcoming EURECA experiment lead to investigations for producing thermometers on smaller crystals which are glued onto the absorber crystal. In our Run 31 we tested composite detectors for the first time in the Gran Sasso setup. They seem to produce higher light yields as hoped and could provide an additional time based discrimination mechanism for low light yield clamp events.
△ Less
Submitted 1 December, 2009;
originally announced December 2009.
-
Electron and Gamma Background in CRESST Detectors
Authors:
R. F. Lang,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
B. Majorovits,
M. Malek,
R. McGowan
, et al. (17 additional authors not shown)
Abstract:
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle interactions in an ultra low background environment. In this paper, we analyze the background spectra that are recorded by three detectors over many weeks of data taking. Understanding these spectra is mandatory if one wants to further reduce the background level, and allows us to cross-check the calibration of the detec…
▽ More
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle interactions in an ultra low background environment. In this paper, we analyze the background spectra that are recorded by three detectors over many weeks of data taking. Understanding these spectra is mandatory if one wants to further reduce the background level, and allows us to cross-check the calibration of the detectors. We identify a variety of sources, such as intrinsic contaminations due to primordial radioisotopes and cosmogenic activation of the target material. In particular, we detect a 3.6keV X-ray line from the decay of 41-Ca with an activity of (26\pm4)μBq, corresponding to a ratio 41-Ca/40-Ca=(2.2\pm0.3)\times10^{-16}.
△ Less
Submitted 26 May, 2009;
originally announced May 2009.
-
Discrimination of Recoil Backgrounds in Scintillating Calorimeters
Authors:
R. F. Lang,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
M. Malek,
R. McGowan,
V. B. Mikhailik
, et al. (16 additional authors not shown)
Abstract:
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event searches. Here, we describe observations related to this alpha decay in the Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a way to dis…
▽ More
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event searches. Here, we describe observations related to this alpha decay in the Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a way to discriminate this source of nuclear recoil background by means of a scintillating foil, and demonstrate its effectiveness. This leads to an observable difference in the pulse shape of the light detector, which can be used to tag these events. Differences in pulse shape of the phonon detector between lead and electron recoils are also extracted, opening the window to future additional background suppression techniques based on pulse shape discrimination in such experiments.
△ Less
Submitted 26 March, 2009;
originally announced March 2009.
-
Development of cryogenic phonon detectors based on CaMoO4 and ZnWO4 scintillating crystals for direct dark matter search experiments
Authors:
I. Bavykina,
G. Angloher,
D. Hauff,
M. Kiefer,
F. Petricca,
F. Proebst
Abstract:
This work reports on the development of the first phonon detectors based on CaMoO4 and ZnWO4 scintillating crystals for the CRESST-II experiment. In particular, a novel technique for the production of the ZnWO4 phonon detector with a separate thermometer carrier was investigated. The influence of the thermal and mechanical treatment on the scintillation light output of CaMoO4 and ZnWO4 crystals…
▽ More
This work reports on the development of the first phonon detectors based on CaMoO4 and ZnWO4 scintillating crystals for the CRESST-II experiment. In particular, a novel technique for the production of the ZnWO4 phonon detector with a separate thermometer carrier was investigated. The influence of the thermal and mechanical treatment on the scintillation light output of CaMoO4 and ZnWO4 crystals at room temperature is discussed.
△ Less
Submitted 12 November, 2008;
originally announced November 2008.
-
Glued CaWO4 Detectors for the CRESST-II Experiment
Authors:
Michael Kiefer,
Franz Pröbst,
Godehard Angloher,
Irina Bavykina,
Dieter Hauff,
Wolfgang Seidel
Abstract:
The Cryogenic Rare Event Search with Superconducting Thermometers Phase II (CRESST-II) at the L.N.G.S in Italy is searching for Dark Matter using low-temperature calorimeters. These detectors allow to discriminate different particles by simultaneous measurement of phonons and scintillation light. The sensors used consist of superconducting tungsten thin-film thermometers, which measure the therm…
▽ More
The Cryogenic Rare Event Search with Superconducting Thermometers Phase II (CRESST-II) at the L.N.G.S in Italy is searching for Dark Matter using low-temperature calorimeters. These detectors allow to discriminate different particles by simultaneous measurement of phonons and scintillation light. The sensors used consist of superconducting tungsten thin-film thermometers, which measure the thermal effect of the phonons created in an attached absorber crystal. It has been observed that the scintillation of the CaWO4 absorber degrades during the process of depositing the tungsten film. In order to prevent this, a new technique for producing the detectors was investigated. This technique might also be valuable by expanding the range of scintillator materials suitable for producing a Dark Matter detector.
△ Less
Submitted 21 October, 2008; v1 submitted 29 September, 2008;
originally announced September 2008.
-
Commissioning Run of the CRESST-II Dark Matter Search
Authors:
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
R. F. Lang,
B. Majorovits,
M. Malek,
R. McGowan
, et al. (18 additional authors not shown)
Abstract:
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~ 300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to detect…
▽ More
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~ 300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to detect the scintillation light from the CaWO_4.Information from light-quenching factor studies allows the definition of a region of the energy-light yield plane which corresponds to tungsten recoils. A neutron test is reported which supports the principle of using the light yield to identify the recoiling nucleus.
Data obtained with two detector modules for a total exposure of 48 kg-days are presented. Judging by the rate of events in the "all nuclear recoils" acceptance region the apparatus shows a factor ~ten improvement with respect to previous results, which we attribute principally to the presence of the neutron shield.
In the "tungsten recoils" acceptance region three events are found, corresponding to a rate of 0.063 per kg-day. Standard assumptions on the dark matter flux, coherent or spin independent interactions,then yield a limit for WIMP-nucleon scattering of 4.8 \times 10^{-7}pb, at M{WIMP} ~50 GeV.
△ Less
Submitted 16 February, 2009; v1 submitted 10 September, 2008;
originally announced September 2008.