A measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics
Authors:
D. Cintas,
S. Hedges,
W. G. Thompson,
P. An,
C. Awe,
P. S. Barbeau,
E. Barbosa de Souza,
J. H. Jo,
L. Li,
M. Martínez,
R. H. Maruyama,
G. C. Rich,
R. Runge,
M. L. Sarsa
Abstract:
The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for WIMP searches and CEνNS measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among th…
▽ More
The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for WIMP searches and CEνNS measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CEνNS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the non-proportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements.
△ Less
Submitted 1 July, 2024; v1 submitted 19 February, 2024;
originally announced February 2024.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Quenching Factor consistency across several NaI(Tl) crystals
Authors:
D. Cintas,
P. An,
C. Awe,
P. S. Barbeau,
E. Barbosa de Souza,
S. Hedges,
J. H. Jo,
M. Martinez,
R. H. Maruyama,
L. Li,
G. C. Rich,
J. Runge,
M. L. Sarsa,
W. G. Thompson
Abstract:
Testing the DAMA/LIBRA annual modulation result independently of dark matter particle and halo models has been a challenge for twenty years. Using the same target material, NaI(Tl), is required and presently two experiments, ANAIS-112 and COSINE-100, are running for such a goal. A precise knowledge of the detector response to nuclear recoils is mandatory because this is the most likely channel to…
▽ More
Testing the DAMA/LIBRA annual modulation result independently of dark matter particle and halo models has been a challenge for twenty years. Using the same target material, NaI(Tl), is required and presently two experiments, ANAIS-112 and COSINE-100, are running for such a goal. A precise knowledge of the detector response to nuclear recoils is mandatory because this is the most likely channel to find the dark matter signal. The light produced by nuclear recoils is quenched with respect to that produced by electrons by a factor that has to be measured experimentally. However, current quenching factor measurements in NaI(Tl) crystals disagree within the energy region of interest for dark matter searches. To disentangle whether this discrepancy is due to intrinsic differences in the light response among different NaI(Tl) crystals, or has its origin in unaccounted for systematic effects will be key in the comparison among the different experiments. We present measurements of the quenching factors for five small NaI(Tl) crystals performed in the same experimental setup to control systematics. Quenching factor results are compatible between crystals and no clear dependence with energy is observed from 10 to 80 keVnr.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.
-
Liquid Scintillator Response to Proton Recoils in the 10-100 keV Range
Authors:
C. Awe,
P. S. Barbeau,
J. I. Collar,
S. Hedges,
L. Li
Abstract:
We study the response of EJ-301 liquid scintillator to monochromatic 244.6 $\pm$ 8.4 keV neutrons, targeting the 10-100 keV proton recoil energy interval. Limited experimental information exists for proton light yield in this range, for this or any other organic scintillator. Our results confirm the adequacy of a modified Birks' model, common to all organic scintillator formulations, predicting a…
▽ More
We study the response of EJ-301 liquid scintillator to monochromatic 244.6 $\pm$ 8.4 keV neutrons, targeting the 10-100 keV proton recoil energy interval. Limited experimental information exists for proton light yield in this range, for this or any other organic scintillator. Our results confirm the adequacy of a modified Birks' model, common to all organic scintillator formulations, predicting a marked increase in quenching factor as proton energy approaches the few keV regime. The relevance of this behavior within the context of searches for low-mass particle dark matter is mentioned.
△ Less
Submitted 7 May, 2018; v1 submitted 17 April, 2018;
originally announced April 2018.