QUBIC IV: Performance of TES Bolometers and Readout Electronics
Authors:
M. Piat,
G. Stankowiak,
E. S. Battistelli,
P. de Bernardis,
G. D Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
T. D. Hoang,
S. Marnieros,
S. Masi,
A. Mennella,
L. Mousset,
C. O Sullivan,
D. Prele,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade,
J. G. Alberro,
A. Almela,
G. Amico,
L. H. Arnaldi
, et al. (104 additional authors not shown)
Abstract:
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are…
▽ More
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are controlled and amplified by an SiGe application specific integrated circuit at 40 K. We report the performance of this readout chain and the characterization of the TES. The readout system has been functionally tested and characterized in the lab and in QUBIC. The low noise amplifier demonstrated a white noise level of 0.3 nV.Hz^-0.5. Characterizations of the QUBIC detectors and readout electronics includes the measurement of I-V curves, time constant and the noise equivalent power. The QUBIC TES bolometer array has approximately 80% detectors within operational parameters. It demonstrated a thermal decoupling compatible with a phonon noise of about 5.10^-17 W.Hz^-0.5 at 410 mK critical temperature. While still limited by microphonics from the pulse tubes and noise aliasing from readout system, the instrument noise equivalent power is about 2.10^-16 W.Hz^-0.5, enough for the demonstration of bolometric interferometry.
△ Less
Submitted 20 October, 2021; v1 submitted 17 January, 2021;
originally announced January 2021.
-
Efficient Differential Fourier-Transform Spectrometer for precision Sunyaev-Zel'dovich effect measurements
Authors:
Alessandro Schillaci,
Giuseppe D' Alessandro,
Paolo de Bernardis,
Silvia Masi,
Camila Paiva Novaes,
Massimo Gervasi,
Mario Zannoni
Abstract:
Precision measurements of the Sunyaev-Zel'dovich effect in clusters of galaxies require excellent rejection of common-mode signals and wide frequency coverage. We describe an imaging, efficient, differential Fourier transform spectrometer (FTS), optimized for measurements of faint brightness gradients at millimeter wavelengths. Our instrument is based on a Martin-Puplett interferometer (MPI) confi…
▽ More
Precision measurements of the Sunyaev-Zel'dovich effect in clusters of galaxies require excellent rejection of common-mode signals and wide frequency coverage. We describe an imaging, efficient, differential Fourier transform spectrometer (FTS), optimized for measurements of faint brightness gradients at millimeter wavelengths. Our instrument is based on a Martin-Puplett interferometer (MPI) configuration. We combined two MPIs working synchronously to use the whole input power. In our implementation the observed sky field is divided into two halves along the meridian, and each half-field corresponds to one of the two input ports of the MPI. In this way, each detector in the FTS focal planes measures the difference in brightness between two sky pixels, symmetrically located with respect to the meridian. Exploiting the high common-mode rejection of the MPI, we can measure low sky brightness gradients over a high isotropic background. The instrument works in the range $\sim$ 1$-$20 cm$^{-1}$ (30$-$600 GHz), has a maximum spectral resolution $1/(2 \ OPD) = 0.063 \ cm^{-1}$ (1.9 GHz), and an unvignetted throughput of 2.3 cm$^2$sr. It occupies a volume of 0.7$\times$0.7$\times$0.33 m$^3$ and has a weight of 70 kg. This design can be implemented as a cryogenic unit to be used in space, as well as a room-temperature unit working at the focus of suborbital and ground-based mm-wave telescopes. The first in-flight test of the instrument is with the OLIMPO experiment on a stratospheric balloon; a larger implementation is being prepared for the Sardinia radio telescope.
△ Less
Submitted 26 May, 2014; v1 submitted 17 February, 2014;
originally announced February 2014.
-
On the emissivity of wire-grid polarizers for astronomical observations at mm-wavelengths
Authors:
Alessandro Schillaci,
Elia Battistelli,
Giuseppe D' Alessandro,
Paolo de Bernardis,
Silvia Masi
Abstract:
We have measured, using a custom setup, the emissivity of metallic wire-grids, suitable for polarimeters and interferometers at mm and far infrared wavelengths. We find that the effective emissivity of these devices is of the order of a few %, depending on fabrication technology and aging. We discuss their use in astronomical instruments, with special attention to Martin Puplett Interferometers in…
▽ More
We have measured, using a custom setup, the emissivity of metallic wire-grids, suitable for polarimeters and interferometers at mm and far infrared wavelengths. We find that the effective emissivity of these devices is of the order of a few %, depending on fabrication technology and aging. We discuss their use in astronomical instruments, with special attention to Martin Puplett Interferometers in low-background applications, like astronomical observations of the Cosmic Microwave Background.
△ Less
Submitted 17 December, 2012;
originally announced December 2012.
-
SWIPE: a bolometric polarimeter for the Large-Scale Polarization Explorer
Authors:
P. de Bernardis,
S. Aiola,
G. Amico,
E. Battistelli,
A. Coppolecchia,
A. Cruciani,
A. D' Addabbo,
G. D' Alessandro,
S. De Gregori,
M. De Petris,
D. Goldie,
R. Gualtieri,
V. Haynes,
L. Lamagna,
B. Maffei,
S. Masi,
F. Nati,
M. Wah Ng,
L. Pagano,
F. Piacentini,
L. Piccirillo,
G. Pisano,
G. Romeo,
M. Salatino,
A. Schillaci
, et al. (2 additional authors not shown)
Abstract:
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components and filters cryogenically cooled below 4K to reduce the background on the detectors. Polarimetry is ac…
▽ More
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components and filters cryogenically cooled below 4K to reduce the background on the detectors. Polarimetry is achieved by means of large rotating half-wave plates and wire-grid polarizers in front of the arrays. The polarization modulator is the first component of the optical chain, reducing significantly the effect of instrumental polarization. In SWIPE we trade angular resolution for sensitivity. The diameter of the entrance pupil of the refractive telescope is 45 cm, while the field optics is optimized to collect tens of modes for each detector, thus boosting the absorbed power. This approach results in a FWHM resolution of 1.8, 1.5, 1.2 degrees at 95, 145, 245 GHz respectively. The expected performance of the three channels is limited by photon noise, resulting in a final sensitivity around 0.1-0.2 uK per beam, for a 13 days survey covering 25% of the sky.
△ Less
Submitted 1 August, 2012;
originally announced August 2012.
-
Low-resolution spectroscopy of the Sunyaev-Zel'dovich effect and estimates of cluster parameters
Authors:
Paolo de Bernardis,
Sergio Colafrancesco,
Giuseppe D' Alessandro,
Luca Lamagna,
Paolo Marchegiani,
Silvia Masi,
Alessandro Schillaci
Abstract:
The Sunyaev-Zel'dovich (SZ) effect is a powerful tool for studying clusters of galaxies and cosmology. Large mm-wave telescopes are now routinely detecting and mapping the SZ effect in a number of clusters, measure their comptonisation parameter and use them as probes of the large-scale structure and evolution of the universe. We show that estimates of the physical parameters of clusters (optical…
▽ More
The Sunyaev-Zel'dovich (SZ) effect is a powerful tool for studying clusters of galaxies and cosmology. Large mm-wave telescopes are now routinely detecting and mapping the SZ effect in a number of clusters, measure their comptonisation parameter and use them as probes of the large-scale structure and evolution of the universe. We show that estimates of the physical parameters of clusters (optical depth, plasma temperature, peculiar velocity, non-thermal components etc.) obtained from ground-based multi-band SZ photometry can be significantly biased, owing to the reduced frequency coverage, to the degeneracy between the parameters and to the presence of a number of independent components larger than the number of frequencies measured. We demonstrate that low-resolution spectroscopic measurements of the SZ effect that also cover frequencies $> 270$ GHz are effective in removing the degeneracy. We used accurate simulations of observations with lines-of-sight through clusters of galaxies with different experimental configurations (4-band photometers, 6-band photometer, multi-range differential spectrometer, full coverage spectrometers) and different intracluster plasma stratifications. We find that measurements carried out with ground-based few-band photometers are biased towards high electron temperatures and low optical depths, and require coverage of high frequency and/or independent complementary observations to produce unbiased information; a differential spectrometer that covers 4 bands with a resolution of $\sim 6 \ GHz$ eliminates most if not all bias; full-range differential spectrometers are the ultimate resource that allows a full recovery of all parameters.
△ Less
Submitted 19 November, 2011;
originally announced November 2011.