Computational 3D topographic microscopy from terabytes of data per sample
Authors:
Kevin C. Zhou,
Mark Harfouche,
Maxwell Zheng,
Joakim Jönsson,
Kyung Chul Lee,
Ron Appel,
Paul Reamey,
Thomas Doman,
Veton Saliu,
Gregor Horstmeyer,
Roarke Horstmeyer
Abstract:
We present a large-scale computational 3D topographic microscope that enables 6-gigapixel profilometric 3D imaging at micron-scale resolution across $>$110 cm$^2$ areas over multi-millimeter axial ranges. Our computational microscope, termed STARCAM (Scanning Topographic All-in-focus Reconstruction with a Computational Array Microscope), features a parallelized, 54-camera architecture with 3-axis…
▽ More
We present a large-scale computational 3D topographic microscope that enables 6-gigapixel profilometric 3D imaging at micron-scale resolution across $>$110 cm$^2$ areas over multi-millimeter axial ranges. Our computational microscope, termed STARCAM (Scanning Topographic All-in-focus Reconstruction with a Computational Array Microscope), features a parallelized, 54-camera architecture with 3-axis translation to capture, for each sample of interest, a multi-dimensional, 2.1-terabyte (TB) dataset, consisting of a total of 224,640 9.4-megapixel images. We developed a self-supervised neural network-based algorithm for 3D reconstruction and stitching that jointly estimates an all-in-focus photometric composite and 3D height map across the entire field of view, using multi-view stereo information and image sharpness as a focal metric. The memory-efficient, compressed differentiable representation offered by the neural network effectively enables joint participation of the entire multi-TB dataset during the reconstruction process. To demonstrate the broad utility of our new computational microscope, we applied STARCAM to a variety of decimeter-scale objects, with applications ranging from cultural heritage to industrial inspection.
△ Less
Submitted 5 June, 2023;
originally announced June 2023.
-
Tensorial tomographic Fourier Ptychography with applications to muscle tissue imaging
Authors:
Shiqi Xu,
Xiang Dai,
Paul Ritter,
Kyung Chul Lee,
Xi Yang,
Lucas Kreiss,
Kevin C. Zhou,
Kanghyun Kim,
Amey Chaware,
Jadee Neff,
Carolyn Glass,
Seung Ah Lee,
Oliver Friedrich,
Roarke Horstmeyer
Abstract:
We report Tensorial tomographic Fourier Ptychography (ToFu), a new non-scanning label-free tomographic microscopy method for simultaneous imaging of quantitative phase and anisotropic specimen information in 3D. Built upon Fourier Ptychography, a quantitative phase imaging technique, ToFu additionally highlights the vectorial nature of light. The imaging setup consists of a standard microscope equ…
▽ More
We report Tensorial tomographic Fourier Ptychography (ToFu), a new non-scanning label-free tomographic microscopy method for simultaneous imaging of quantitative phase and anisotropic specimen information in 3D. Built upon Fourier Ptychography, a quantitative phase imaging technique, ToFu additionally highlights the vectorial nature of light. The imaging setup consists of a standard microscope equipped with an LED matrix, a polarization generator, and a polarization-sensitive camera. Permittivity tensors of anisotropic samples are computationally recovered from polarized intensity measurements across three dimensions. We demonstrate ToFu's efficiency through volumetric reconstructions of refractive index, birefringence, and orientation for various validation samples, as well as tissue samples from muscle fibers and diseased heart tissue. Our reconstructions of muscle fibers resolve their 3D fine-filament structure and yield consistent morphological measurements compared to gold-standard second harmonic generation scanning confocal microscope images found in the literature. Additionally, we demonstrate reconstructions of a heart tissue sample that carries important polarization information for detecting cardiac amyloidosis.
△ Less
Submitted 13 May, 2023; v1 submitted 8 May, 2023;
originally announced May 2023.
-
Digital staining in optical microscopy using deep learning -- a review
Authors:
Lucas Kreiss,
Shaowei Jiang,
Xiang Li,
Shiqi Xu,
Kevin C. Zhou,
Alexander Mühlberg,
Kyung Chul Lee,
Kanghyun Kim,
Amey Chaware,
Michael Ando,
Laura Barisoni,
Seung Ah Lee,
Guoan Zheng,
Kyle Lafata,
Oliver Friedrich,
Roarke Horstmeyer
Abstract:
Until recently, conventional biochemical staining had the undisputed status as well-established benchmark for most biomedical problems related to clinical diagnostics, fundamental research and biotechnology. Despite this role as gold-standard, staining protocols face several challenges, such as a need for extensive, manual processing of samples, substantial time delays, altered tissue homeostasis,…
▽ More
Until recently, conventional biochemical staining had the undisputed status as well-established benchmark for most biomedical problems related to clinical diagnostics, fundamental research and biotechnology. Despite this role as gold-standard, staining protocols face several challenges, such as a need for extensive, manual processing of samples, substantial time delays, altered tissue homeostasis, limited choice of contrast agents for a given sample, 2D imaging instead of 3D tomography and many more. Label-free optical technologies, on the other hand, do not rely on exogenous and artificial markers, by exploiting intrinsic optical contrast mechanisms, where the specificity is typically less obvious to the human observer. Over the past few years, digital staining has emerged as a promising concept to use modern deep learning for the translation from optical contrast to established biochemical contrast of actual stainings. In this review article, we provide an in-depth analysis of the current state-of-the-art in this field, suggest methods of good practice, identify pitfalls and challenges and postulate promising advances towards potential future implementations and applications.
△ Less
Submitted 14 March, 2023;
originally announced March 2023.
-
Parallelized computational 3D video microscopy of freely moving organisms at multiple gigapixels per second
Authors:
Kevin C. Zhou,
Mark Harfouche,
Colin L. Cooke,
Jaehee Park,
Pavan C. Konda,
Lucas Kreiss,
Kanghyun Kim,
Joakim Jönsson,
Jed Doman,
Paul Reamey,
Veton Saliu,
Clare B. Cook,
Maxwell Zheng,
Jack P. Bechtel,
Aurélien Bègue,
Matthew McCarroll,
Jennifer Bagwell,
Gregor Horstmeyer,
Michel Bagnat,
Roarke Horstmeyer
Abstract:
To study the behavior of freely moving model organisms such as zebrafish (Danio rerio) and fruit flies (Drosophila) across multiple spatial scales, it would be ideal to use a light microscope that can resolve 3D information over a wide field of view (FOV) at high speed and high spatial resolution. However, it is challenging to design an optical instrument to achieve all of these properties simulta…
▽ More
To study the behavior of freely moving model organisms such as zebrafish (Danio rerio) and fruit flies (Drosophila) across multiple spatial scales, it would be ideal to use a light microscope that can resolve 3D information over a wide field of view (FOV) at high speed and high spatial resolution. However, it is challenging to design an optical instrument to achieve all of these properties simultaneously. Existing techniques for large-FOV microscopic imaging and for 3D image measurement typically require many sequential image snapshots, thus compromising speed and throughput. Here, we present 3D-RAPID, a computational microscope based on a synchronized array of 54 cameras that can capture high-speed 3D topographic videos over a 135-cm^2 area, achieving up to 230 frames per second at throughputs exceeding 5 gigapixels (GPs) per second. 3D-RAPID features a 3D reconstruction algorithm that, for each synchronized temporal snapshot, simultaneously fuses all 54 images seamlessly into a globally-consistent composite that includes a coregistered 3D height map. The self-supervised 3D reconstruction algorithm itself trains a spatiotemporally-compressed convolutional neural network (CNN) that maps raw photometric images to 3D topography, using stereo overlap redundancy and ray-propagation physics as the only supervision mechanism. As a result, our end-to-end 3D reconstruction algorithm is robust to generalization errors and scales to arbitrarily long videos from arbitrarily sized camera arrays. The scalable hardware and software design of 3D-RAPID addresses a longstanding problem in the field of behavioral imaging, enabling parallelized 3D observation of large collections of freely moving organisms at high spatiotemporal throughputs, which we demonstrate in ants (Pogonomyrmex barbatus), fruit flies, and zebrafish larvae.
△ Less
Submitted 19 January, 2023;
originally announced January 2023.
-
Imaging across multiple spatial scales with the multi-camera array microscope
Authors:
Mark Harfouche,
Kanghyun Kim,
Kevin C. Zhou,
Pavan Chandra Konda,
Sunanda Sharma,
Eric E. Thomson,
Colin Cooke,
Shiqi Xu,
Lucas Kreiss,
Amey Chaware,
Xi Yang,
Xing Yao,
Vinayak Pathak,
Martin Bohlen,
Ron Appel,
Aurélien Bègue,
Clare Cook,
Jed Doman,
John Efromson,
Gregor Horstmeyer,
Jaehee Park,
Paul Reamey,
Veton Saliu,
Eva Naumann,
Roarke Horstmeyer
Abstract:
This article experimentally examines different configurations of a novel multi-camera array microscope (MCAM) imaging technology. The MCAM is based upon a densely packed array of "micro-cameras" to jointly image across a large field-of-view at high resolution. Each micro-camera within the array images a unique area of a sample of interest, and then all acquired data with 54 micro-cameras are digit…
▽ More
This article experimentally examines different configurations of a novel multi-camera array microscope (MCAM) imaging technology. The MCAM is based upon a densely packed array of "micro-cameras" to jointly image across a large field-of-view at high resolution. Each micro-camera within the array images a unique area of a sample of interest, and then all acquired data with 54 micro-cameras are digitally combined into composite frames, whose total pixel counts significantly exceed the pixel counts of standard microscope systems. We present results from three unique MCAM configurations for different use cases. First, we demonstrate a configuration that simultaneously images and estimates the 3D object depth across a 100 x 135 mm^2 field-of-view (FOV) at approximately 20 um resolution, which results in 0.15 gigapixels (GP) per snapshot. Second, we demonstrate an MCAM configuration that records video across a continuous 83 x 123 mm^2 FOV with two-fold increased resolution (0.48 GP per frame). Finally, we report a third high-resolution configuration (2 um resolution) that can rapidly produce 9.8 GP composites of large histopathology specimens.
△ Less
Submitted 28 February, 2023; v1 submitted 30 November, 2022;
originally announced December 2022.
-
Multi-modal imaging using a cascaded microscope design
Authors:
Xi Yang,
Mark Harfouche,
Kevin C. Zhou,
Lucas Kreiss,
Shiqi Xu,
Kanghyun Kim,
Roarke Horstmeyer
Abstract:
We present a new Multimodal Fiber Array Snapshot Technique (M-FAST), based on an array of 96 compact cameras placed behind a primary objective lens and a fiber bundle array. which is capable of large-area, high-resolution, multi-channel video acquisition. The proposed design provides two key improvements to prior cascaded imaging system approaches: a novel optical arrangement that accommodates the…
▽ More
We present a new Multimodal Fiber Array Snapshot Technique (M-FAST), based on an array of 96 compact cameras placed behind a primary objective lens and a fiber bundle array. which is capable of large-area, high-resolution, multi-channel video acquisition. The proposed design provides two key improvements to prior cascaded imaging system approaches: a novel optical arrangement that accommodates the use of planar camera arrays, and the new ability to acquire multi-modal image data acquisition. M-FAST is a multi-modal, scalable imaging system that can acquire snapshot dual-channel fluorescence images as well as d phase contrast measurements over a large 8x10mm^2 FOV at 2.2um full-pitch resolution.
△ Less
Submitted 18 August, 2022;
originally announced August 2022.
-
Tensorial tomographic differential phase-contrast microscopy
Authors:
Shiqi Xu,
Xiang Dai,
Xi Yang,
Kevin C. Zhou,
Kanghyun Kim,
Vinayak Pathak,
Carolyn Glass,
Roarke Horstmeyer
Abstract:
We report Tensorial Tomographic Differential Phase-Contrast microscopy (T2DPC), a quantitative label-free tomographic imaging method for simultaneous measurement of phase and anisotropy. T2DPC extends differential phase-contrast microscopy, a quantitative phase imaging technique, to highlight the vectorial nature of light. The method solves for permittivity tensor of anisotropic samples from inten…
▽ More
We report Tensorial Tomographic Differential Phase-Contrast microscopy (T2DPC), a quantitative label-free tomographic imaging method for simultaneous measurement of phase and anisotropy. T2DPC extends differential phase-contrast microscopy, a quantitative phase imaging technique, to highlight the vectorial nature of light. The method solves for permittivity tensor of anisotropic samples from intensity measurements acquired with a standard microscope equipped with an LED matrix, a circular polarizer, and a polarization-sensitive camera. We demonstrate accurate volumetric reconstructions of refractive index, birefringence, and orientation for various validation samples, and show that the reconstructed polarization structures of a biological specimen are predictive of pathology.
△ Less
Submitted 6 September, 2022; v1 submitted 24 April, 2022;
originally announced April 2022.
-
Transient motion classification through turbid volumes via parallelized single-photon detection and deep contrastive embedding
Authors:
Shiqi Xu,
Wenhui Liu,
Xi Yang,
Joakim Jönsson,
Ruobing Qian,
Paul McKee,
Kanghyun Kim,
Pavan Chandra Konda,
Kevin C. Zhou,
Lucas Kreiß,
Haoqian Wang,
Edouard Berrocal,
Scott Huettel,
Roarke Horstmeyer
Abstract:
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy an…
▽ More
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed Classifying Rapid decorrelation Events via Parallelized single photon dEtection (CREPE)}, a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a $32\times32$ pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1-0.4s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to noninvasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe.
△ Less
Submitted 12 June, 2022; v1 submitted 4 April, 2022;
originally announced April 2022.
-
Computational 3D microscopy with optical coherence refraction tomography
Authors:
Kevin C. Zhou,
Ryan P. McNabb,
Ruobing Qian,
Simone Degan,
Al-Hafeez Dhalla,
Sina Farsiu,
Joseph A. Izatt
Abstract:
Optical coherence tomography (OCT) has seen widespread success as an in vivo clinical diagnostic 3D imaging modality, impacting areas including ophthalmology, cardiology, and gastroenterology. Despite its many advantages, such as high sensitivity, speed, and depth penetration, OCT suffers from several shortcomings that ultimately limit its utility as a 3D microscopy tool, such as its pervasive coh…
▽ More
Optical coherence tomography (OCT) has seen widespread success as an in vivo clinical diagnostic 3D imaging modality, impacting areas including ophthalmology, cardiology, and gastroenterology. Despite its many advantages, such as high sensitivity, speed, and depth penetration, OCT suffers from several shortcomings that ultimately limit its utility as a 3D microscopy tool, such as its pervasive coherent speckle noise and poor lateral resolution required to maintain millimeter-scale imaging depths. Here, we present 3D optical coherence refraction tomography (OCRT), a computational extension of OCT which synthesizes an incoherent contrast mechanism by combining multiple OCT volumes, acquired across two rotation axes, to form a resolution-enhanced, speckle-reduced, refraction-corrected 3D reconstruction. Our label-free computational 3D microscope features a novel optical design incorporating a parabolic mirror to enable the capture of 5D plenoptic datasets, consisting of millimetric 3D fields of view over up to $\pm75^\circ$ without moving the sample. We demonstrate that 3D OCRT reveals 3D features unobserved by conventional OCT in fruit fly, zebrafish, and mouse samples.
△ Less
Submitted 23 February, 2022;
originally announced February 2022.
-
Increasing a microscope's effective field of view via overlapped imaging and machine learning
Authors:
Xing Yao,
Vinayak Pathak,
Haoran Xi,
Amey Chaware,
Colin Cooke,
Kanghyun Kim,
Shiqi Xu,
Yuting Li,
Timothy Dunn,
Pavan Chandra Konda,
Kevin C. Zhou,
Roarke Horstmeyer
Abstract:
This work demonstrates a multi-lens microscopic imaging system that overlaps multiple independent fields of view on a single sensor for high-efficiency automated specimen analysis. Automatic detection, classification and counting of various morphological features of interest is now a crucial component of both biomedical research and disease diagnosis. While convolutional neural networks (CNNs) hav…
▽ More
This work demonstrates a multi-lens microscopic imaging system that overlaps multiple independent fields of view on a single sensor for high-efficiency automated specimen analysis. Automatic detection, classification and counting of various morphological features of interest is now a crucial component of both biomedical research and disease diagnosis. While convolutional neural networks (CNNs) have dramatically improved the accuracy of counting cells and sub-cellular features from acquired digital image data, the overall throughput is still typically hindered by the limited space-bandwidth product (SBP) of conventional microscopes. Here, we show both in simulation and experiment that overlapped imaging and co-designed analysis software can achieve accurate detection of diagnostically-relevant features for several applications, including counting of white blood cells and the malaria parasite, leading to multi-fold increase in detection and processing throughput with minimal reduction in accuracy.
△ Less
Submitted 10 October, 2021;
originally announced October 2021.
-
Quantitative Jones matrix imaging using vectorial Fourier ptychography
Authors:
Xiang Dai,
Shiqi Xu,
Xi Yang,
Kevin C. Zhou,
Carolyn Glass,
Pavan Chandra Konda,
Roarke Horstmeyer
Abstract:
This paper presents a microscopic imaging technique that uses variable-angle illumination to recover the complex polarimetric properties of a specimen at high resolution and over a large field-of-view. The approach extends Fourier ptychography, which is a synthetic aperture-based imaging approach to improve resolution with phaseless measurements, to additionally account for the vectorial nature of…
▽ More
This paper presents a microscopic imaging technique that uses variable-angle illumination to recover the complex polarimetric properties of a specimen at high resolution and over a large field-of-view. The approach extends Fourier ptychography, which is a synthetic aperture-based imaging approach to improve resolution with phaseless measurements, to additionally account for the vectorial nature of light. After images are acquired using a standard microscope outfitted with an LED illumination array and two polarizers, our vectorial Fourier Ptychography (vFP) algorithm solves for the complex 2x2 Jones matrix of the anisotropic specimen of interest at each resolved spatial location. We introduce a new sequential Gauss-Newton-based solver that additionally jointly estimates and removes polarization-dependent imaging system aberrations. We demonstrate effective vFP performance by generating large-area (29 mm$^2$), high-resolution (1.24 $μ$m full-pitch) reconstructions of sample absorption, phase, orientation, diattenuation, and retardance for a variety of calibration samples and biological specimens.
△ Less
Submitted 15 October, 2021; v1 submitted 30 September, 2021;
originally announced October 2021.
-
Imaging dynamics beneath turbid media via parallelized single-photon detection
Authors:
Shiqi Xu,
Xi Yang,
Wenhui Liu,
Joakim Jonsson,
Ruobing Qian,
Pavan Chandra Konda,
Kevin C. Zhou,
Lucas Kreiss,
Qionghai Dai,
Haoqian Wang,
Edouard Berrocal,
Roarke Horstmeyer
Abstract:
Noninvasive optical imaging through dynamic scattering media has numerous important biomedical applications but still remains a challenging task. While standard diffuse imaging methods measure optical absorption or fluorescent emission, it is also well-established that the temporal correlation of scattered coherent light diffuses through tissue much like optical intensity. Few works to date, howev…
▽ More
Noninvasive optical imaging through dynamic scattering media has numerous important biomedical applications but still remains a challenging task. While standard diffuse imaging methods measure optical absorption or fluorescent emission, it is also well-established that the temporal correlation of scattered coherent light diffuses through tissue much like optical intensity. Few works to date, however, have aimed to experimentally measure and process such temporal correlation data to demonstrate deep-tissue video reconstruction of decorrelation dynamics. In this work, we utilize a single-photon avalanche diode (SPAD) array camera to simultaneously monitor the temporal dynamics of speckle fluctuations at the single-photon level from 12 different phantom tissue surface locations delivered via a customized fiber bundle array. We then apply a deep neural network to convert the acquired single-photon measurements into video of scattering dynamics beneath rapidly decorrelating tissue phantoms. We demonstrate the ability to reconstruct images of transient (0.1-0.4s) dynamic events occurring up to 8 mm beneath a decorrelating tissue phantom with millimeter-scale resolution, and highlight how our model can flexibly extend to monitor flow speed within buried phantom vessels.
△ Less
Submitted 12 June, 2022; v1 submitted 3 July, 2021;
originally announced July 2021.
-
High-speed multiview imaging approaching 4pi steradians using conic section mirrors: theoretical and practical considerations
Authors:
Kevin C. Zhou,
Al-Hafeez Dhalla,
Ryan P. McNabb,
Ruobing Qian,
Sina Farsiu,
Joseph A. Izatt
Abstract:
Illuminating or imaging samples from a broad angular range is essential in a wide variety of computational 3D imaging and resolution-enhancement techniques, such as optical projection tomography (OPT), optical diffraction tomography (ODT), synthetic aperture microscopy, Fourier ptychographic microscopy (FPM), structured illumination microscopy (SIM), photogrammetry, and optical coherence refractio…
▽ More
Illuminating or imaging samples from a broad angular range is essential in a wide variety of computational 3D imaging and resolution-enhancement techniques, such as optical projection tomography (OPT), optical diffraction tomography (ODT), synthetic aperture microscopy, Fourier ptychographic microscopy (FPM), structured illumination microscopy (SIM), photogrammetry, and optical coherence refraction tomography (OCRT). The wider the angular coverage, the better the resolution enhancement or 3D resolving capabilities. However, achieving such angular ranges is a practical challenge, especially when approaching plus-or-minus 90 degrees or beyond. Often, researchers resort to expensive, proprietary high numerical aperture (NA) objectives, or to rotating the sample or source-detector pair, which sacrifices temporal resolution or perturbs the sample. Here, we propose several new strategies for multi-angle imaging approaching 4pi steradians using concave parabolic or ellipsoidal mirrors and fast, low rotational inertia scanners, such as galvanometers. We derive theoretically and empirically relations between a variety of system parameters (e.g., NA, wavelength, focal length, telecentricity) and achievable fields of view (FOVs) and importantly show that intrinsic tilt aberrations do not restrict FOV for many multi-view imaging applications, contrary to conventional wisdom. Finally, we present strategies for avoiding spherical aberrations at obliquely illuminated flat boundaries. Our simple designs allow for high-speed multi-angle imaging for microscopic, mesoscopic, and macroscopic applications.
△ Less
Submitted 17 November, 2021; v1 submitted 30 June, 2021;
originally announced June 2021.
-
In Vivo Quantitative Analysis of Anterior Chamber White Blood Cell Mixture Composition Using Spectroscopic Optical Coherence Tomography
Authors:
Ruobing Qian,
Ryan P. McNabb,
Kevin C. Zhou,
Hazem M. Mousa,
Daniel R. Saban,
Victor L. Perez,
Anthony N. Kuo,
Joseph A. Izatt
Abstract:
Anterior uveitis is the most common form of intraocular inflammation, and one of its main signs is the presence of white blood cells (WBCs) in the anterior chamber (AC). Clinically, the true composition of cells can currently only be obtained using AC paracentesis, an invasive procedure to obtain AC fluid requiring needle insertion into the AC. We previously developed a spectroscopic optical coher…
▽ More
Anterior uveitis is the most common form of intraocular inflammation, and one of its main signs is the presence of white blood cells (WBCs) in the anterior chamber (AC). Clinically, the true composition of cells can currently only be obtained using AC paracentesis, an invasive procedure to obtain AC fluid requiring needle insertion into the AC. We previously developed a spectroscopic optical coherence tomography (SOCT) analysis method to differentiate between populations of RBCs and subtypes of WBCs, including granulocytes, lymphocytes and monocytes, both in vitro and in ACs of excised porcine eyes. We have shown that different types of WBCs have distinct characteristic size distributions, extracted from the backscattered reflectance spectrum of individual cells using Mie theory. Here, we further develop our method to estimate the composition of blood cell mixtures, both in vitro and in vivo. To do so, we estimate the size distribution of unknown cell mixtures by fitting the distribution observed using SOCT with a weighted combination of reference size distributions of each WBC type calculated using kernel density estimation. We validate the accuracy of our estimation in an in vitro study, by comparing our results for a given WBC sample mixture with the cellular concentrations measured by a hemocytometer and SOCT images before mixing. We also conducted a small in vivo quantitative cell mixture validation pilot study which demonstrates congruence between our method and AC paracentesis in two patients with uveitis. The SOCT based method appears promising to provide quantitative diagnostic information of cellular responses in the ACs of patients with uveitis.
△ Less
Submitted 11 January, 2021;
originally announced January 2021.
-
Mesoscopic photogrammetry with an unstabilized phone camera
Authors:
Kevin C. Zhou,
Colin Cooke,
Jaehee Park,
Ruobing Qian,
Roarke Horstmeyer,
Joseph A. Izatt,
Sina Farsiu
Abstract:
We present a feature-free photogrammetric technique that enables quantitative 3D mesoscopic (mm-scale height variation) imaging with tens-of-micron accuracy from sequences of images acquired by a smartphone at close range (several cm) under freehand motion without additional hardware. Our end-to-end, pixel-intensity-based approach jointly registers and stitches all the images by estimating a coali…
▽ More
We present a feature-free photogrammetric technique that enables quantitative 3D mesoscopic (mm-scale height variation) imaging with tens-of-micron accuracy from sequences of images acquired by a smartphone at close range (several cm) under freehand motion without additional hardware. Our end-to-end, pixel-intensity-based approach jointly registers and stitches all the images by estimating a coaligned height map, which acts as a pixel-wise radial deformation field that orthorectifies each camera image to allow homographic registration. The height maps themselves are reparameterized as the output of an untrained encoder-decoder convolutional neural network (CNN) with the raw camera images as the input, which effectively removes many reconstruction artifacts. Our method also jointly estimates both the camera's dynamic 6D pose and its distortion using a nonparametric model, the latter of which is especially important in mesoscopic applications when using cameras not designed for imaging at short working distances, such as smartphone cameras. We also propose strategies for reducing computation time and memory, applicable to other multi-frame registration problems. Finally, we demonstrate our method using sequences of multi-megapixel images captured by an unstabilized smartphone on a variety of samples (e.g., painting brushstrokes, circuit board, seeds).
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
Unified k-space theory of optical coherence tomography
Authors:
Kevin C. Zhou,
Ruobing Qian,
Al-Hafeez Dhalla,
Sina Farsiu,
Joseph A. Izatt
Abstract:
We present a general theory of optical coherence tomography (OCT), which synthesizes the fundamental concepts and implementations of OCT under a common 3D k-space framework. At the heart of this analysis is the Fourier diffraction theorem, which relates the coherent interaction between a sample and plane wave to the Ewald sphere in the 3D k-space representation of the sample. While only the axial…
▽ More
We present a general theory of optical coherence tomography (OCT), which synthesizes the fundamental concepts and implementations of OCT under a common 3D k-space framework. At the heart of this analysis is the Fourier diffraction theorem, which relates the coherent interaction between a sample and plane wave to the Ewald sphere in the 3D k-space representation of the sample. While only the axial dimension of OCT is typically analyzed in k-space, we show that embracing a fully 3D k-space formalism allows explanation of nearly every fundamental physical phenomenon or property of OCT, including contrast mechanism, resolution, dispersion, aberration, limited depth of focus, and speckle. The theory also unifies diffraction tomography, confocal microscopy, point-scanning OCT, line-field OCT, full-field OCT, Bessel-beam OCT, transillumination OCT, interferometric synthetic aperture microscopy (ISAM), and optical coherence refraction tomography (OCRT), among others. Our unified theory not only enables clear understanding of existing techniques, but also suggests new research directions to continue advancing the field of OCT.
△ Less
Submitted 9 December, 2020;
originally announced December 2020.
-
Video-rate high-precision time-frequency multiplexed 3D coherent ranging
Authors:
Ruobing Qian,
Kevin C. Zhou,
Jingkai Zhang,
Christian Viehland,
Al-Hafeez Dhalla,
Joseph A. Izatt
Abstract:
Recently, there has been growing interest and effort in developing high-speed high-precision 3D imaging technologies for a wide range of industrial, automotive and biomedical applications. Optical frequency-modulated continuous wave (FMCW) light detection and ranging (LiDAR), which shares the same working principle as swept-source optical coherence tomography (SSOCT), is an emerging 3D surface ima…
▽ More
Recently, there has been growing interest and effort in developing high-speed high-precision 3D imaging technologies for a wide range of industrial, automotive and biomedical applications. Optical frequency-modulated continuous wave (FMCW) light detection and ranging (LiDAR), which shares the same working principle as swept-source optical coherence tomography (SSOCT), is an emerging 3D surface imaging technology that offers higher sensitivity and resolution than conventional time-of-flight (ToF) ranging. Recently, with the development of high-performance swept sources with meter-scale instantaneous coherence lengths, the imaging range of both OCT and FMCW has been significantly improved. However, due to the limited bandwidth of current generation digitizers and the speed limitations of beam steering using mechanical scanners, long range OCT and FMCW typically suffer from a low 3D frame rate (<1Hz), which greatly restricts their applications in imaging dynamic or moving objects. In this work, we report a high-speed FMCW based 3D surface imaging system, combining a grating for beam steering with a compressed time-frequency analysis approach for depth retrieval. We thoroughly investigate the localization accuracy and precision of our system both theoretically and experimentally. Finally, we demonstrate 3D surface imaging results of multiple static and moving objects, including a flexing human hand. The demonstrated technique performs 3D surface imaging with submillimeter localization accuracy over a tens-of-centimeter imaging range with an overall depth voxel acquisition rate of 7.6 MHz, enabling densely sampled 3D surface imaging at video rate.
△ Less
Submitted 20 October, 2020; v1 submitted 13 August, 2020;
originally announced August 2020.
-
Physics-enhanced machine learning for virtual fluorescence microscopy
Authors:
Colin L. Cooke,
Fanjie Kong,
Amey Chaware,
Kevin C. Zhou,
Kanghyun Kim,
Rong Xu,
D. Michael Ando,
Samuel J. Yang,
Pavan Chandra Konda,
Roarke Horstmeyer
Abstract:
This paper introduces a new method of data-driven microscope design for virtual fluorescence microscopy. Our results show that by including a model of illumination within the first layers of a deep convolutional neural network, it is possible to learn task-specific LED patterns that substantially improve the ability to infer fluorescence image information from unstained transmission microscopy ima…
▽ More
This paper introduces a new method of data-driven microscope design for virtual fluorescence microscopy. Our results show that by including a model of illumination within the first layers of a deep convolutional neural network, it is possible to learn task-specific LED patterns that substantially improve the ability to infer fluorescence image information from unstained transmission microscopy images. We validated our method on two different experimental setups, with different magnifications and different sample types, to show a consistent improvement in performance as compared to conventional illumination methods. Additionally, to understand the importance of learned illumination on inference task, we varied the dynamic range of the fluorescent image targets (from one to seven bits), and showed that the margin of improvement for learned patterns increased with the information content of the target. This work demonstrates the power of programmable optical elements at enabling better machine learning algorithm performance and at providing physical insight into next generation of machine-controlled imaging systems.
△ Less
Submitted 21 April, 2020; v1 submitted 8 April, 2020;
originally announced April 2020.
-
Diffraction tomography with a deep image prior
Authors:
Kevin C. Zhou,
Roarke Horstmeyer
Abstract:
We present a tomographic imaging technique, termed Deep Prior Diffraction Tomography (DP-DT), to reconstruct the 3D refractive index (RI) of thick biological samples at high resolution from a sequence of low-resolution images collected under angularly varying illumination. DP-DT processes the multi-angle data using a phase retrieval algorithm that is extended by a deep image prior (DIP), which rep…
▽ More
We present a tomographic imaging technique, termed Deep Prior Diffraction Tomography (DP-DT), to reconstruct the 3D refractive index (RI) of thick biological samples at high resolution from a sequence of low-resolution images collected under angularly varying illumination. DP-DT processes the multi-angle data using a phase retrieval algorithm that is extended by a deep image prior (DIP), which reparameterizes the 3D sample reconstruction with an untrained, deep generative 3D convolutional neural network (CNN). We show that DP-DT effectively addresses the missing cone problem, which otherwise degrades the resolution and quality of standard 3D reconstruction algorithms. As DP-DT does not require pre-captured data or pre-training, it is not biased towards any particular dataset. Hence, it is a general technique that can be applied to a wide variety of 3D samples, including scenarios in which large datasets for supervised training would be infeasible or expensive. We applied DP-DT to obtain 3D RI maps of bead phantoms and complex biological specimens, both in simulation and experiment, and show that DP-DT produces higher-quality results than standard regularization techniques. We further demonstrate the generality of DP-DT, using two different scattering models, the first Born and multi-slice models. Our results point to the potential benefits of DP-DT for other 3D imaging modalities, including X-ray computed tomography, magnetic resonance imaging, and electron microscopy.
△ Less
Submitted 10 December, 2019;
originally announced December 2019.