-
Design and behaviour of the Large Hadron Collider external beam dumps capable of receiving 539 MJ/dump
Authors:
J. Maestre,
C. Torregrosa,
K. Kershaw,
C. Bracco,
T. Coiffet,
M. Ferrari,
R. Franqueira Ximenes,
S. Gilardoni,
D. Grenier,
A. Lechner,
V. Maire,
J. M. Martin Ruiz,
E. Matheson,
N. Solieri,
A. Perillo Marcone,
T. Polzin,
V. Rizzoglio,
D. Senajova,
C. Sharp,
M. Timmins,
M. Calviani
Abstract:
Two 6-t beam dumps, made of a graphite core encapsulated in a stainless steel vessel, are used to absorb the energy of the two Large Hadron Collider (LHC) intense proton beams during operation of the accelerator. Operational issues started to appear in 2015 during LHC Run 2 (2014-2018) as a consequence of the progressive increase of the LHC beam kinetic energy, necessitating technical intervention…
▽ More
Two 6-t beam dumps, made of a graphite core encapsulated in a stainless steel vessel, are used to absorb the energy of the two Large Hadron Collider (LHC) intense proton beams during operation of the accelerator. Operational issues started to appear in 2015 during LHC Run 2 (2014-2018) as a consequence of the progressive increase of the LHC beam kinetic energy, necessitating technical interventions in the highly radioactive areas around the dumps. Nitrogen gas leaks appeared after highly energetic beam impacts and instrumentation measurements indicated an initially unforeseen movement of the dumps. A computer modelling analysis campaign was launched to understand the origin of these issues, including both Monte Carlo simulations to model the proton beam interaction as well as advanced thermo-mechanical analyses. The main findings were that the amount of instantaneous energy deposited in the dump vessel leads to a strong dynamic response of the whole dump and high accelerations (above 2000g). Based on these findings, an upgraded design, including a new support system and beam windows, was implemented to ensure the dumps' compatibility with the more intense beams foreseen during LHC Run 3 (2022-2025) of 539 MJ per beam. In this paper an integral overview of the operational behaviour of the dumps and the upgraded configurations are discussed.
△ Less
Submitted 27 October, 2021; v1 submitted 17 October, 2021;
originally announced October 2021.
-
Full Scale Proton Beam Impact Testing of new CERN Collimators and Validation of a Numerical Approach for Future Operation
Authors:
M. Bergeret,
F-X. Nuiry,
M. Calviani,
M. A. Fraser,
M. Butcher,
L-M. Grec,
L. Gentini,
A. Lechner,
M. Frankl,
V. Rizzoglio,
S. Burger,
A. Cherif
Abstract:
New collimators are being produced at CERN in the framework of a large particle accelerator upgrade project to protect beam lines against stray particles. Their movable jaws hold low density absorbers with tight geometric requirements, while being able to withstand direct proton beam impacts. Such events induce considerable thermo-mechanical loads, leading to complex structural responses, which ma…
▽ More
New collimators are being produced at CERN in the framework of a large particle accelerator upgrade project to protect beam lines against stray particles. Their movable jaws hold low density absorbers with tight geometric requirements, while being able to withstand direct proton beam impacts. Such events induce considerable thermo-mechanical loads, leading to complex structural responses, which make the numerical analysis challenging. Hence, an experiment has been developed to validate the jaw design under representative conditions and to acquire online results to enhance the numerical models. Two jaws have been impacted by high-intensity proton beams in a dedicated facility at CERN and have recreated the worst possible scenario in future operation. The analysis of online results coupled to post-irradiation examinations have demonstrated that the jaw response remains in the elastic domain. However, they have also highlighted how sensitive the jaw geometry is to its mounting support inside the collimator. Proton beam impacts, as well as handling activities, may alter the jaw flatness tolerance value by $\pm$ 70 $μ$m, whereas the flatness tolerance requirement is 200 $μ$m. In spite of having validated the jaw design for this application, the study points out numerical limitations caused by the difficulties in describing complex geometries and boundary conditions with such unprecedented requirements.
△ Less
Submitted 26 April, 2019;
originally announced April 2019.
-
Large energy acceptance gantry for proton therapy utilizing superconducting technology
Authors:
K. P. Nesteruk,
C. Calzolaio,
D. Meer,
V. Rizzoglio,
M. Seidel,
J. M. Schippers
Abstract:
When using superconducting (SC) magnets in a gantry for proton therapy, the gantry will benefit from some reduction in size and a large reduction in weight. In this contribution we show an important additional advantage of SC magnets in proton therapy treatments. We present the design of a gantry with a SC bending section and achromatic beam optics with a very large beam momentum acceptance of…
▽ More
When using superconducting (SC) magnets in a gantry for proton therapy, the gantry will benefit from some reduction in size and a large reduction in weight. In this contribution we show an important additional advantage of SC magnets in proton therapy treatments. We present the design of a gantry with a SC bending section and achromatic beam optics with a very large beam momentum acceptance of $\pm15\%$. Due to the related very large energy acceptance, approximately 70% of the treatments can be performed without changing the magnetic field for synchronization with energy modulation. In our design this is combined with a 2D lateral scanning system and a fast degrader mounted in the gantry, so that this gantry will be able to perform pencil beam scanning with very rapid energy variations at the patient, allowing a significant reduction of the irradiation time.
We describe the iterative process we have applied to design the magnets and the beam transport, for which we have used different codes. COSY Infinity and OPAL have been used to design the beam transport optics and to track the particles in the magnetic fields, which are produced by the magnets designed in Opera. With beam optics calculations we have derived an optimal achromatic beam transport with the large momentum acceptance of the proton pencil beam and we show the agreement with particle tracking calculations in the 3D magnetic field map.
A new cyclotron based facility with this gantry will have a significantly smaller footprint, since one can refrain from the degrader and energy selection system behind the cyclotron. In the treatments, this gantry will enable a very fast proton beam delivery sequence, which may be of advantage for treatments in moving tissue.
△ Less
Submitted 7 January, 2019;
originally announced January 2019.
-
On the accuracy of Monte Carlo based beam dynamics models for the degrader in proton therapy facilities
Authors:
V. Rizzoglio,
A. Adelmann,
C. Baumgarten,
D. Meer,
J. Snuverink,
V. Talanov
Abstract:
In a cyclotron-based proton therapy facility, the energy changes are performed by means of a degrader of variable thickness. The interaction of the proton beam with the degrader creates energy tails and increases the beam emittance. A precise model of the degraded beam properties is important not only to better understand the performance of a facility already in operation, but also to support the…
▽ More
In a cyclotron-based proton therapy facility, the energy changes are performed by means of a degrader of variable thickness. The interaction of the proton beam with the degrader creates energy tails and increases the beam emittance. A precise model of the degraded beam properties is important not only to better understand the performance of a facility already in operation, but also to support the development of new proton therapy concepts. The exact knowledge of the degraded beam properties, in terms of energy spectrum and transverse phase space, depends on the model used to describe the proton interaction with the degrader material. In this work the model of a graphite degrader has been developed with four Monte Carlo codes: three conventional Monte Carlo codes (FLUKA, GEANT4 and MCNPX) and the multi-purpose particle tracking code OPAL equipped with a simplified Monte Carlo routine. From the comparison between the different codes, we can deduce how the accuracy of the degrader model influences the precision of the beam dynamics model of a possible transport line downstream of the degrader.
△ Less
Submitted 20 February, 2018; v1 submitted 1 December, 2017;
originally announced December 2017.
-
Evolution of a beam dynamics model for the transport lines in a proton therapy facility
Authors:
V. Rizzoglio,
A. Adelmann,
C. Baumgarten,
M. Frey,
A. Gerbershagen,
D. Meer,
J. M. Schippers
Abstract:
Despite the fact that the first-order beam dynamics models allow an approximated evaluation of the beam properties, their contribution is essential during the conceptual design of an accelerator or beamline. However, during the commissioning some of their limitations appear in the comparison against measurements. The extension of the linear model to higher order effects is, therefore, demanded. In…
▽ More
Despite the fact that the first-order beam dynamics models allow an approximated evaluation of the beam properties, their contribution is essential during the conceptual design of an accelerator or beamline. However, during the commissioning some of their limitations appear in the comparison against measurements. The extension of the linear model to higher order effects is, therefore, demanded. In this paper, the effects of particle-matter interaction have been included in the model of the transport lines in the proton therapy facility at the Paul Scherrer Institut (PSI) in Switzerland. To improve the performance of the facility, a more precise model was required and has been developed with the multi-particle open source beam dynamics code called OPAL (Object oriented Particle Accelerator Library). In OPAL, the Monte Carlo simulations of Coulomb scattering and energy loss are performed seamless with the particle tracking. Beside the linear optics, the influence of the passive elements (e.g. degrader, collimators, scattering foils and air gaps) on the beam emittance and energy spread can be analysed in the new model. This allows for a significantly improved precision in the prediction of beam transmission and beam properties. The accuracy of the OPAL model has been confirmed by numerous measurements.
△ Less
Submitted 14 November, 2017; v1 submitted 30 May, 2017;
originally announced May 2017.
-
Cyclinac Medical Accelerators Using Pulsed C6+/H2+ Ion Sources
Authors:
A. Garonna,
U. Amaldi,
R. Bonomi,
D. Campo,
A. Degiovanni,
M. Garlasché,
I. Mondino,
V. Rizzoglio,
S. Verdú Andrés
Abstract:
Charged particle therapy, or so-called hadrontherapy, is developing very rapidly. There is large pressure on the scientific community to deliver dedicated accelerators, providing the best possible treatment modalities at the lowest cost. In this context, the Italian research Foundation TERA is developing fast-cycling accelerators, dubbed 'cyclinacs'. These are a combination of a cyclotron (acceler…
▽ More
Charged particle therapy, or so-called hadrontherapy, is developing very rapidly. There is large pressure on the scientific community to deliver dedicated accelerators, providing the best possible treatment modalities at the lowest cost. In this context, the Italian research Foundation TERA is developing fast-cycling accelerators, dubbed 'cyclinacs'. These are a combination of a cyclotron (accelerating ions to a fixed initial energy) followed by a high gradient linac boosting the ions energy up to the maximum needed for medical therapy. The linac is powered by many independently controlled klystrons to vary the beam energy from one pulse to the next. This accelerator is best suited to treat moving organs with a 4D multi-painting spot scanning technique. A dual proton/carbon ion cyclinac is here presented. It consists of an Electron Beam Ion Source, a superconducting isochronous cyclotron and a high-gradient linac. All these machines are pulsed at high repetition rate (100-400 Hz). The source should deliver both C6+ and H2+ ions in short pulses (1.5 μs flat-top) and with sufficient intensity (at least 108 fully stripped carbon ions at 300 Hz). The cyclotron accelerates the ions to 120 MeV/u. It features a compact design (with superconducting coils) and a low power consumption. The linac has a novel C-band high gradient structure and accelerates the ions to variable energies up to 400 MeV/u. High RF frequencies lead to power consumptions which are much lower than the ones of synchrotrons for the same ion extraction energy. This work is part of a collaboration with the CLIC group, which is working at CERN on high-gradient electron-positron colliders.
△ Less
Submitted 11 August, 2010; v1 submitted 2 July, 2010;
originally announced July 2010.