Analysis methods for in-beam PET images in proton therapy treatment verification: a comparison based on Monte Carlo simulations
Authors:
M. Moglioni,
A. C. Kraan,
A. Berti,
P. Carra,
P. Cerello,
M. Ciocca,
V. Ferrero,
E. Fiorina,
E. Mazzoni,
M. Morrocchi,
F. Pennazio,
A. Retico,
V. Rosso,
G. Sportelli,
V. Vitolo,
G. Bisogni
Abstract:
Background and purpose: In-beam Positron Emission Tomography (PET) is one of the modalities that can be used for in-vivo non-invasive treatment monitoring in proton therapy. PET distributions obtained during various treatment sessions can be compared in order to identify regions that have anatomical changes. The purpose of this work is to test and compare different analysis methods in the context…
▽ More
Background and purpose: In-beam Positron Emission Tomography (PET) is one of the modalities that can be used for in-vivo non-invasive treatment monitoring in proton therapy. PET distributions obtained during various treatment sessions can be compared in order to identify regions that have anatomical changes. The purpose of this work is to test and compare different analysis methods in the context of inter-fractional PET image comparison for proton treatment verification.
Methods: For our study we used the FLUKA Monte Carlo code and artificially generated CT scans to simulate in-beam PET distributions at different stages during proton therapy treatment. We compared the Beam-Eye-View method, the Most-Likely-Shift method, the Voxel-Based-Morphology method and the gamma evaluation method to compare PET images at the start of treatment, and after a few weeks of treatment. The results were compared to the CT scan.
Results and conclusions: Three-dimensional methods like VBM and gamma are preferred above two-dimensional methods like MLS and BEV if much statistics is available, since the these methods allow to identify the regions with anomalous activity. The VBM approach has as disadvantage that a larger number of MC simulations is needed. The gamma analysis has the disadvantage that no clinical indication exist on tolerance criteria. In terms of calculation time, the BEV and MLS method are preferred. We recommend to use the four methods together, in order to best identify the location and cause of the activity changes.
△ Less
Submitted 1 December, 2022; v1 submitted 10 October, 2022;
originally announced October 2022.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
High availability using virtualization - 3RC
Authors:
Federico Calzolari,
Silvia Arezzini,
Alberto Ciampa,
Enrico Mazzoni,
Andrea Domenici,
Gigliola Vaglini
Abstract:
High availability has always been one of the main problems for a data center. Till now high availability was achieved by host per host redundancy, a highly expensive method in terms of hardware and human costs. A new approach to the problem can be offered by virtualization. Using virtualization, it is possible to achieve a redundancy system for all the services running on a data center. This new a…
▽ More
High availability has always been one of the main problems for a data center. Till now high availability was achieved by host per host redundancy, a highly expensive method in terms of hardware and human costs. A new approach to the problem can be offered by virtualization. Using virtualization, it is possible to achieve a redundancy system for all the services running on a data center. This new approach to high availability allows the running virtual machines to be distributed over a small number of servers, by exploiting the features of the virtualization layer: start, stop and move virtual machines between physical hosts. The 3RC system is based on a finite state machine, providing the possibility to restart each virtual machine over any physical host, or reinstall it from scratch. A complete infrastructure has been developed to install operating system and middleware in a few minutes. To virtualize the main servers of a data center, a new procedure has been developed to migrate physical to virtual hosts. The whole Grid data center SNS-PISA is running at the moment in virtual environment under the high availability system.
△ Less
Submitted 2 May, 2012;
originally announced May 2012.
-
A PMT-Block test bench
Authors:
P. Adragna,
A. Antonaki,
I. Boudagov,
V. Cavasinni,
D. Costanzo,
T. Del Prete,
A. Dotti,
D. Fassouliotis,
V. Giakoumopoulou,
N. Giokaris,
C. Guicheney,
E. Karali,
J. Khubua,
M. Lebessi,
A. Lupi,
A. Manoussakis,
E. Mazzoni,
I. Minashvili,
M. Morphi,
G. F. Pagani,
R. Paoletti,
D. Rizzi,
C. Roda,
F. Sarri,
Ath. Staveris-Polykalas
, et al. (8 additional authors not shown)
Abstract:
The front-end electronics of the ATLAS hadronic calorimeter (Tile Cal) is housed in a unit, called {\it PMT-Block}. The PMT-Block is a compact instrument comprising a light mixer, a PMT together with its divider and a {\it 3-in-1} card, which provides shaping, amplification and integration for the signals. This instrument needs to be qualified before being assembled on the detector. A PMT-Block…
▽ More
The front-end electronics of the ATLAS hadronic calorimeter (Tile Cal) is housed in a unit, called {\it PMT-Block}. The PMT-Block is a compact instrument comprising a light mixer, a PMT together with its divider and a {\it 3-in-1} card, which provides shaping, amplification and integration for the signals. This instrument needs to be qualified before being assembled on the detector. A PMT-Block test bench has been developed for this purpose. This test bench is a system which allows fast, albeit accurate enough, measurements of the main properties of a complete PMT-Block. The system, both hardware and software, and the protocol used for the PMT-Blocks characterisation are described in detail in this report. The results obtained in the test of about 10000 PMT-Blocks needed for the instrumentation of the ATLAS (LHC-CERN) hadronic Tile Calorimeter are also reported.
△ Less
Submitted 8 May, 2006;
originally announced May 2006.
-
A device to characterize optical fibres
Authors:
F. Bosi,
S. Burdin,
V. Cavasinni,
D. Costanzo,
T. Del Prete,
V. Flaminio,
E. Mazzoni,
C. Roda,
G. Usai,
A. Vasiljev
Abstract:
ATLAS is a general purpose experiment approved for the LHC collider at CERN. An important component of the detector is the central hadronic calorimeter; for its construction more than 600,000 Wave Length Shifting (WLS) fibres (corresponding to a total length of 1,120 Km) have been used.
We have built and put into operation a dedicated instrument for the measurement of light yield and attenuati…
▽ More
ATLAS is a general purpose experiment approved for the LHC collider at CERN. An important component of the detector is the central hadronic calorimeter; for its construction more than 600,000 Wave Length Shifting (WLS) fibres (corresponding to a total length of 1,120 Km) have been used.
We have built and put into operation a dedicated instrument for the measurement of light yield and attenuation length over groups of 20 fibres at a time.
The overall accuracy achieved in the measurement of light yield
(attenuation length) is 1.5% (3%).
We also report the results obtained using this method in the quality control of a large sample of fibres.
△ Less
Submitted 3 September, 2001;
originally announced September 2001.