Low-frequency pulse-jitter measurement with the uGMRT I : PSR J0437$-$4715
Authors:
Tomonosuke Kikunaga,
Shinnosuke Hisano,
Neelam Dhanda Batra,
Shantanu Desai,
Bhal Chandra Joshi,
Manjari Bagchi,
T. Prabu,
Keitaro Takahashi,
Swetha Arumugam,
Adarsh Bathula,
Subhajit Dandapat,
Debabrata Deb,
Churchil Dwivedi,
Yashwant Gupta,
Shebin Jose Jacob,
Fazal Kareem,
Nobleson K,
Pragna Mamidipaka,
Avinash Kumar Paladi,
Arul Pandian B,
Prerna Rana,
Jaikhomba Singha,
Aman Srivastava,
Mayuresh Surnis,
Pratik Tarafdar
Abstract:
High-precision pulsar timing observations are limited in their accuracy by the jitter noise that appears in the arrival time of pulses. Therefore, it is important to systematically characterise the amplitude of the jitter noise and its variation with frequency. In this paper, we provide jitter measurements from low-frequency wideband observations of PSR J0437$-$4715 using data obtained as part of…
▽ More
High-precision pulsar timing observations are limited in their accuracy by the jitter noise that appears in the arrival time of pulses. Therefore, it is important to systematically characterise the amplitude of the jitter noise and its variation with frequency. In this paper, we provide jitter measurements from low-frequency wideband observations of PSR J0437$-$4715 using data obtained as part of the Indian Pulsar Timing Array experiment. We were able to detect jitter in both the 300 - 500 MHz and 1260 - 1460 MHz observations of the upgraded Giant Metrewave Radio Telescope (uGMRT). The former is the first jitter measurement for this pulsar below 700 MHz, and the latter is in good agreement with results from previous studies. In addition, at 300 - 500 MHz, we investigated the frequency dependence of the jitter by calculating the jitter for each sub-banded arrival time of pulses. We found that the jitter amplitude increases with frequency. This trend is opposite as compared to previous studies, indicating that there is a turnover at intermediate frequencies. It will be possible to investigate this in more detail with uGMRT observations at 550 - 750 MHz and future high sensitive wideband observations from next generation telescopes, such as the Square Kilometre Array. We also explored the effect of jitter on the high precision dispersion measure (DM) measurements derived from short duration observations. We find that even though the DM precision will be better at lower frequencies due to the smaller amplitude of jitter noise, it will limit the DM precision for high signal-to-noise observations, which are of short durations. This limitation can be overcome by integrating for a long enough duration optimised for a given pulsar.
△ Less
Submitted 18 April, 2024; v1 submitted 4 December, 2023;
originally announced December 2023.
Application of Efron-Petrosian method to radio pulsar fluxes
Authors:
Pragna Mamidipaka,
Shantanu Desai
Abstract:
We apply the Efron-Petrosian technique to radio fluxes of pulsars detected in the Parkes multi-beam survey to test the independence of luminosity and distance. For this dataset, we find that for four different distance exponents (ranging from 0.5 to 2), the flux thresholds at which the luminosity and distances are uncorrelated, correspond to very low $p$-values for the Kolmogorov-Smirnov test betw…
▽ More
We apply the Efron-Petrosian technique to radio fluxes of pulsars detected in the Parkes multi-beam survey to test the independence of luminosity and distance. For this dataset, we find that for four different distance exponents (ranging from 0.5 to 2), the flux thresholds at which the luminosity and distances are uncorrelated, correspond to very low $p$-values for the Kolmogorov-Smirnov test between the truncated and untruncated datasets. This is due to the fact that the Parkes multi-beam survey is not sufficiently homogeneous to lend itself to a treatment by the Efron-Petrosian method. We then repeat the analysis after rendering the dataset more homogeneous by excluding the distant pulsars from this sample. We find that for this culled dataset, the flux is consistent with distance exponents of 1.5 and 2.0.
△ Less
Submitted 26 November, 2023; v1 submitted 20 September, 2023;
originally announced September 2023.
Do Pulsar and Fast Radio Burst dispersion measures obey Benford's law?
Authors:
Pragna Mamidipaka,
Shantanu Desai
Abstract:
We check if the first significant digit of the dispersion measure of pulsars and Fast Radio Bursts (using the CHIME catalog) is consistent with the Benford distribution. We find a large disagreement with Benford's law with $χ^2$ close to 80 for 8 degrees of freedom for both these aforementioned datasets. This corresponds to a discrepancy of about 7$σ$. Therefore, we conclude that the dispersion me…
▽ More
We check if the first significant digit of the dispersion measure of pulsars and Fast Radio Bursts (using the CHIME catalog) is consistent with the Benford distribution. We find a large disagreement with Benford's law with $χ^2$ close to 80 for 8 degrees of freedom for both these aforementioned datasets. This corresponds to a discrepancy of about 7$σ$. Therefore, we conclude that the dispersion measures of pulsars and FRBs do not obey Benford's law.
△ Less
Submitted 20 July, 2022;
originally announced July 2022.