-
Lumped Element Kinetic Inductance Detectors for space applications
Authors:
Alessandro Monfardini,
Jochem Baselmans,
Alain Benoit,
Aurelien Bideaud,
Olivier Bourrion,
Andrea Catalano,
Martino Calvo,
Antonio D'Addabbo,
Simon Doyle,
Johannes Goupy,
Helene Le Sueur,
Juan Macias-Perez,
NIKA2 collaboration,
SPACEKIDS collaboration,
B-SIDE collaboration
Abstract:
Kinetic Inductance Detectors (KID) are now routinely used in ground-based telescopes. Large arrays, deployed in formats up to kilopixels, exhibit state-of-the-art performance at millimeter (e.g. 120-300 GHz, NIKA and NIKA2 on the IRAM 30-meters) and sub-millimeter (e.g. 350-850 GHz AMKID on APEX) wavelengths. In view of future utilizations above the atmosphere, we have studied in detail the intera…
▽ More
Kinetic Inductance Detectors (KID) are now routinely used in ground-based telescopes. Large arrays, deployed in formats up to kilopixels, exhibit state-of-the-art performance at millimeter (e.g. 120-300 GHz, NIKA and NIKA2 on the IRAM 30-meters) and sub-millimeter (e.g. 350-850 GHz AMKID on APEX) wavelengths. In view of future utilizations above the atmosphere, we have studied in detail the interaction of ionizing particles with LEKID (Lumped Element KID) arrays. We have constructed a dedicated cryogenic setup that allows to reproduce the typical observing conditions of a space-borne observatory. We will report the details and conclusions from a number of measurements. We give a brief description of our short term project, consisting in flying LEKID on a stratospheric balloon named B-SIDE.
△ Less
Submitted 2 June, 2016;
originally announced June 2016.
-
High angular resolution SZ observations with NIKA and NIKA2
Authors:
B. Comis,
R. Adam,
P. Ade,
P. André,
M. Arnaud,
I. Bartalucci,
A. Beelen,
A. Benoît,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
G. Lagache,
S. Leclercq,
J. F. Macías-Pérez,
P. Mauskopf,
F. Mayet,
A. Monfardini,
F. Pajot
, et al. (17 additional authors not shown)
Abstract:
NIKA2 (New IRAM KID Arrays) is a dual band (150 and 260 GHz) imaging camera based on Kinetic Inductance Detectors (KIDs) and designed to work at the IRAM 30 m telescope (Pico Veleta, Spain). Built on the experience of the NIKA prototype, NIKA2 has been installed at the 30 m focal plane in October 2015 and the commissioning phase is now ongoing. Through the thermal Sunyaev-Zeldovich (tSZ) effect, N…
▽ More
NIKA2 (New IRAM KID Arrays) is a dual band (150 and 260 GHz) imaging camera based on Kinetic Inductance Detectors (KIDs) and designed to work at the IRAM 30 m telescope (Pico Veleta, Spain). Built on the experience of the NIKA prototype, NIKA2 has been installed at the 30 m focal plane in October 2015 and the commissioning phase is now ongoing. Through the thermal Sunyaev-Zeldovich (tSZ) effect, NIKA2 will image the ionized gas residing in clusters of galaxies with a resolution of 12 and 18 arcsec FWHM (at 150 and 260 GHz, respectively). We report on the recent tSZ measurements with the NIKA camera and discuss the future objectives for the NIKA2 SZ large Program, 300h of observation dedicated to SZ science. With this program we intend to perform a high angular resolution follow-up of a cosmologically-representative sample of clusters belonging to SZ catalogues, with redshift greater than 0.5. The main output of the program will be the study of the redshift evolution of the cluster pressure profile as well as that of the scaling laws relating the cluster global properties.
△ Less
Submitted 31 May, 2016;
originally announced May 2016.
-
The NIKA2 commissioning campaign: performance and first results
Authors:
A. Catalano,
R. Adam,
P. Ade,
P. André,
H. Aussel,
A. Beelen,
A. Benoît,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
G. Coiffard,
B. Comis,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. F. Kramer,
G. Lagache,
S. Leclercq,
J. F. Lestrade,
J. F. Macías-Pérez,
A. Maury,
P. Mauskopf,
F. Mayet,
A. Monfardini
, et al. (17 additional authors not shown)
Abstract:
The New IRAM KID Array 2 (NIKA 2) is a dual-band camera operating with three frequency-multiplexed kilopixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK. NIKA 2 is designed to observe the intensity and polarisation of the sky at 1.15 and 2.0 mm wavelength from the IRAM 30 m telescope. The NIKA 2 instrument represents a huge step in performance as compared to the…
▽ More
The New IRAM KID Array 2 (NIKA 2) is a dual-band camera operating with three frequency-multiplexed kilopixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK. NIKA 2 is designed to observe the intensity and polarisation of the sky at 1.15 and 2.0 mm wavelength from the IRAM 30 m telescope. The NIKA 2 instrument represents a huge step in performance as compared to the NIKA pathfinder instrument, which has already shown state-of-the-art detector and photometric performance. After the commissioning planned to be accomplished at the end of 2016, NIKA 2 will be an IRAM resident instrument for the next ten years or more. NIKA 2 should allow the astrophysical community to tackle a large number of open questions reaching from the role of the Galactic magnetic field in star formation to the discrepancy between cluster-based and CMB-based cosmology possibly induced by the unknown cluster physics. We present an overview of the commissioning phase together with some first results.
△ Less
Submitted 31 May, 2016; v1 submitted 27 May, 2016;
originally announced May 2016.
-
High-resolution tSZ cartography of clusters of galaxies with NIKA at the IRAM 30-m telescope
Authors:
F. Mayet,
R. Adam,
A. Adane,
P. Ade,
P. André,
M. Arnaud,
I. Bartalucci,
A. Beelen,
A. Benoît,
A. Bideaud,
N. Billot,
G. Blanquer,
N. Boudou,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
B. Comis,
A. Cruciani,
F. -X. Désert,
S. Doyle,
J. Goupy,
B. Hasnoun,
I. Hermelo,
C. Kramer
, et al. (19 additional authors not shown)
Abstract:
The thermal Sunyaev-Zeldovich effect (tSZ) is a powerful probe to study clusters of galaxies and is complementary with respect to X-ray, lensing or optical observations. Previous arcmin resolution tSZ observations ({\it e.g.} SPT, ACT and Planck) only enabled detailed studies of the intra-cluster medium morphology for low redshift clusters ($z < 0.2$). Thus, the development of precision cosmology…
▽ More
The thermal Sunyaev-Zeldovich effect (tSZ) is a powerful probe to study clusters of galaxies and is complementary with respect to X-ray, lensing or optical observations. Previous arcmin resolution tSZ observations ({\it e.g.} SPT, ACT and Planck) only enabled detailed studies of the intra-cluster medium morphology for low redshift clusters ($z < 0.2$). Thus, the development of precision cosmology with clusters requires high angular resolution observations to extend the understanding of galaxy cluster towards high redshift. NIKA2 is a wide-field (6.5 arcmin field of view) dual-band camera, operated at $100 \ {\rm mK}$ and containing $\sim 3300$ KID (Kinetic Inductance Detectors), designed to observe the millimeter sky at 150 and 260 GHz, with an angular resolution of 18 and 12 arcsec respectively. The NIKA2 camera has been installed on the IRAM 30-m telescope (Pico Veleta, Spain) in September 2015. The NIKA2 tSZ observation program will allow us to observe a large sample of clusters (50) at redshift ranging between 0.5 and 1. As a pathfinder for NIKA2, several clusters of galaxies have been observed at the IRAM 30-m telescope with the NIKA prototype to cover the various configurations and observation conditions expected for NIKA2.
△ Less
Submitted 25 February, 2016;
originally announced February 2016.
-
NIKA 2: next-generation continuum/polarized camera at the IRAM 30 m telescope and its prototype
Authors:
A. Ritacco,
R. Adam,
A. Adane,
P. Ade,
P. André,
A. Beelen,
A. Benoît,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
B. Comis,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. F. Macías-Pérez,
P. Mauskopf,
A. Maury,
F. Mayet,
A. Monfardini,
F. Pajot
, et al. (14 additional authors not shown)
Abstract:
NIKA 2 (New Instrument of Kids Array) is a next generation continuum and polarized instrument successfully installed in October 2015 at the IRAM 30 m telescope on Pico-Veleta (Granada, Spain). NIKA 2 is a high resolution dual-band camera, operating with frequency multiplexed LEKIDs (Lumped Element Kinetic Inductance Detectors) cooled at 100 mK. Dual color images are obtained thanks to the simultan…
▽ More
NIKA 2 (New Instrument of Kids Array) is a next generation continuum and polarized instrument successfully installed in October 2015 at the IRAM 30 m telescope on Pico-Veleta (Granada, Spain). NIKA 2 is a high resolution dual-band camera, operating with frequency multiplexed LEKIDs (Lumped Element Kinetic Inductance Detectors) cooled at 100 mK. Dual color images are obtained thanks to the simultaneous readout of a 1020 pixels array at 2 mm and 1140 x 2 pixels arrays at 1.15 mm with a final resolution of 18 and 12 arcsec respectively, and 6.5 arcmin of Field of View (FoV). The two arrays at 1.15 mm allow us to measure the linear polarization of the incoming light. This will place NIKA 2 as an instrument of choice to study the role of magnetic fields in the star formation process. The NIKA experiment, a prototype for NIKA 2 with a reduced number of detectors (about 400 LEKIDs) and FoV (1.8 arcmin), has been successfully operated at the IRAM 30 telescope in several open observational campaigns. The performance of the NIKA 2 polarization setup has been successfully validated with the NIKA prototype.
△ Less
Submitted 4 February, 2016;
originally announced February 2016.
-
NIKEL_AMC: Readout electronics for the NIKA2 experiment
Authors:
O. Bourrion,
A. Benoit,
J. L. Bouly,
J. Bouvier,
G. Bosson,
M. Calvo,
A. Catalano,
J. Goupy,
C. Li,
J. F. Macías-Pérez,
A. Monfardini,
D. Tourres,
N. Ponchant,
C. Vescovi
Abstract:
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically de…
▽ More
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.
△ Less
Submitted 25 October, 2016; v1 submitted 3 February, 2016;
originally announced February 2016.
-
Microfabrication technology for large LEKID arrays : from NIKA2 to future applications
Authors:
J. Goupy,
A. Adane,
A. Benoit,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
C. Hoarau,
S. Leclercq,
H. Le Sueur,
J. Macias-Perez,
A. Monfardini,
I. Peck,
K. Schuster
Abstract:
The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon) in the mm and sub-mm range. A continuing effort is ongoing to improve the microfabrication technologies and concepts in order to satisfy the requirements of new…
▽ More
The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon) in the mm and sub-mm range. A continuing effort is ongoing to improve the microfabrication technologies and concepts in order to satisfy the requirements of new instruments. More precisely, future satellites dedicated to CMB (Cosmic Microwave Background) studies will require the same focal plane technology to cover, at least, the frequency range of 60 to 600 GHz. Aluminium LEKID developed for NIKA have so far demonstrated, under real telescope conditions, performance approaching photon-noise limitation in the band 120-300 GHz. By implementing superconducting bi-layers we recently demonstrated LEKID arrays working in the range 80-120 GHz and with sensitivities approaching the goals for CMB missions. NIKA itself (350 pixels) is followed by a more ambitious project requiring several thousands (3000-5000) pixels. NIKA2 has been installed in October 2015 at the IRAM 30-m telescope. We will describe in detail the technological improvements that allowed a relatively harmless 10-fold up-scaling in pixels count without degrading the initial sensitivity. In particular we will briefly describe a solution to simplify the difficult fabrication step linked to the slot-line propagation mode in coplanar waveguide.
△ Less
Submitted 15 January, 2016;
originally announced January 2016.
-
The NIKA2 instrument, a dual-band kilopixel KID array for millimetric astronomy
Authors:
M. Calvo,
A. Benoit,
A. Catalano,
J. Goupy,
A. Monfardini,
N. Ponthieu,
E. Barria,
G. Bres,
M. Grollier,
G. Garde,
J. -P. Leggeri,
G. Pont,
S. Triqueneaux,
R. Adam,
O. Bourrion,
J. -F. Macías-Pérez,
M. Rebolo,
A. Ritacco,
J. -P. Scordilis,
D. Tourres,
C. Vescovi,
F. -X. Désert,
A. Adane,
G. Coiffard,
S. Leclercq
, et al. (23 additional authors not shown)
Abstract:
NIKA2 (New IRAM KID Array 2) is a camera dedicated to millimeter wave astronomy based upon kilopixel arrays of Kinetic Inductance Detectors (KID). The pathfinder instrument, NIKA, has already shown state-of-the-art detector performance. NIKA2 builds upon this experience but goes one step further, increasing the total pixel count by a factor $\sim$10 while maintaining the same per pixel performance…
▽ More
NIKA2 (New IRAM KID Array 2) is a camera dedicated to millimeter wave astronomy based upon kilopixel arrays of Kinetic Inductance Detectors (KID). The pathfinder instrument, NIKA, has already shown state-of-the-art detector performance. NIKA2 builds upon this experience but goes one step further, increasing the total pixel count by a factor $\sim$10 while maintaining the same per pixel performance. For the next decade, this camera will be the resident photometric instrument of the Institut de Radio Astronomie Millimetrique (IRAM) 30m telescope in Sierra Nevada (Spain). In this paper we give an overview of the main components of NIKA2, and describe the achieved detector performance. The camera has been permanently installed at the IRAM 30m telescope in October 2015. It will be made accessible to the scientific community at the end of 2016, after a one-year commissioning period. When this happens, NIKA2 will become a fundamental tool for astronomers worldwide.
△ Less
Submitted 12 January, 2016;
originally announced January 2016.
-
Lumped element kinetic inductance detectors maturity for space-borne instruments in the range between 80 and 180 GHz
Authors:
A. Catalano,
A. Benoit,
O. Bourrion,
M. Calvo,
G. Coiffard,
A. D'Addabbo,
J. Goupy,
H. Le Sueur,
J. Macìas-Pérez,
A. Monfardini
Abstract:
This work intends to give the state-of-the-art of our knowledge of the performance of LEKIDs at millimetre wavelengths (from 80 to 180~GHz). We evaluate their optical sensitivity under typical background conditions and their interaction with ionising particles. Two LEKID arrays, originally designed for ground-based applications and composed of a few hundred pixels each, operate at a central freque…
▽ More
This work intends to give the state-of-the-art of our knowledge of the performance of LEKIDs at millimetre wavelengths (from 80 to 180~GHz). We evaluate their optical sensitivity under typical background conditions and their interaction with ionising particles. Two LEKID arrays, originally designed for ground-based applications and composed of a few hundred pixels each, operate at a central frequency of 100, and 150~GHz ($Δν/ ν$ about 0.3). Their sensitivities have been characterised in the laboratory using a dedicated closed-circle 100~mK dilution cryostat and a sky simulator, allowing for the reproduction of realistic, space-like observation conditions. The impact of cosmic rays has been evaluated by exposing the LEKID arrays to alpha particles ($^{241}$Am) and X sources ($^{109}$Cd) with a readout sampling frequency similar to the ones used for Planck HFI (about 200~Hz), and also with a high resolution sampling level (up to 2~MHz) in order to better characterise and interpret the observed glitches. In parallel, we have developed an analytical model to rescale the results to what would be observed by such a LEKID array at the second Lagrangian point.
△ Less
Submitted 25 May, 2016; v1 submitted 9 November, 2015;
originally announced November 2015.
-
High angular resolution Sunyaev-Zel'dovich observations of MACS J1423.8+2404 with NIKA: Multiwavelength analysis
Authors:
R. Adam,
B. Comis,
I. Bartalucci,
A. Adane,
P. Ade,
P. André,
M. Arnaud,
A. Beelen,
B. Belier,
A. Benoît,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
A. D'Addabbo,
F. -X. Désert,
S. Doyle,
J. Goupy,
B. Hasnoun,
I. Hermelo,
C. Kramer,
G. Lagache,
S. Leclercq
, et al. (20 additional authors not shown)
Abstract:
The prototype of the NIKA2 camera, NIKA, is an instrument operating at the IRAM 30-m telescope, which can observe simultaneously at 150 and 260GHz. One of the main goals of NIKA2 is to measure the pressure distribution in galaxy clusters at high resolution using the thermal SZ (tSZ) effect. Such observations have already proved to be an excellent probe of cluster pressure distributions even at hig…
▽ More
The prototype of the NIKA2 camera, NIKA, is an instrument operating at the IRAM 30-m telescope, which can observe simultaneously at 150 and 260GHz. One of the main goals of NIKA2 is to measure the pressure distribution in galaxy clusters at high resolution using the thermal SZ (tSZ) effect. Such observations have already proved to be an excellent probe of cluster pressure distributions even at high redshifts. However, an important fraction of clusters host submm and/or radio point sources, which can significantly affect the reconstructed signal. Here we report on <20" resolution observations at 150 and 260GHz of the cluster MACSJ1424, which hosts both radio and submm point sources. We examine the morphology of the tSZ signal and compare it to other datasets. The NIKA data are combined with Herschel satellite data to study the SED of the submm point source contaminants. We then perform a joint reconstruction of the intracluster medium (ICM) electronic pressure and density by combining NIKA, Planck, XMM-Newton, and Chandra data, focusing on the impact of the radio and submm sources on the reconstructed pressure profile. We find that large-scale pressure distribution is unaffected by the point sources because of the resolved nature of the NIKA observations. The reconstructed pressure in the inner region is slightly higher when the contribution of point sources are removed. We show that it is not possible to set strong constraints on the central pressure distribution without accurately removing these contaminants. The comparison with X-ray only data shows good agreement for the pressure, temperature, and entropy profiles, which all indicate that MACSJ1424 is a dynamically relaxed cool core system. The present observations illustrate the possibility of measuring these quantities with a relatively small integration time, even at high redshift and without X-ray spectroscopy.
△ Less
Submitted 15 February, 2016; v1 submitted 22 October, 2015;
originally announced October 2015.
-
Uniform non-stoichiometric titanium nitride thin films for improved kinetic inductance detector array
Authors:
G. Coiffard,
K-F. Schuster,
E. F. C. Driessen,
S. Pignard,
M. Calvo,
A. Catalano,
J. Goupy,
A. Monfardini
Abstract:
We describe the fabrication of homogeneous sub-stoichiometric titanium nitride films for microwave kinetic inductance detector (mKID) arrays. Using a 6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the critical temperature over a 2 inch wafer was reduced to <25 %. Measurements of a 132-pixel mKID array from these films reveal a sensitivity of 16 kHz/pW in the 100 GHz ba…
▽ More
We describe the fabrication of homogeneous sub-stoichiometric titanium nitride films for microwave kinetic inductance detector (mKID) arrays. Using a 6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the critical temperature over a 2 inch wafer was reduced to <25 %. Measurements of a 132-pixel mKID array from these films reveal a sensitivity of 16 kHz/pW in the 100 GHz band, comparable to the best aluminium mKIDs. We measured a noise equivalent power of NEP = 3.6e-15 W/Hz^(1/2). Finally, we describe possible routes to further improve the performance of these TiN mKID arrays.
△ Less
Submitted 7 January, 2016; v1 submitted 7 October, 2015;
originally announced October 2015.
-
First polarised light with the NIKA camera
Authors:
A. Ritacco,
R. Adam,
A. Adane,
P. Ade,
P. André,
A. Beelen,
B. Belier,
A. Benoît,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
B. Comis,
A. D'Addabbo,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. F. Macías-Pérez,
J. Martino,
P. Mauskopf,
A. Maury
, et al. (17 additional authors not shown)
Abstract:
NIKA is a dual-band camera operating with 315 frequency multiplexed LEKIDs cooled at 100 mK. NIKA is designed to observe the sky in intensity and polarisation at 150 and 260 GHz from the IRAM 30-m telescope. It is a test-bench for the final NIKA2 camera. The incoming linear polarisation is modulated at four times the mechanical rotation frequency by a warm rotating multi-layer Half Wave Plate. The…
▽ More
NIKA is a dual-band camera operating with 315 frequency multiplexed LEKIDs cooled at 100 mK. NIKA is designed to observe the sky in intensity and polarisation at 150 and 260 GHz from the IRAM 30-m telescope. It is a test-bench for the final NIKA2 camera. The incoming linear polarisation is modulated at four times the mechanical rotation frequency by a warm rotating multi-layer Half Wave Plate. Then, the signal is analysed by a wire grid and finally absorbed by the LEKIDs. The small time constant (< 1ms ) of the LEKID detectors combined with the modulation of the HWP enables the quasi-simultaneous measurement of the three Stokes parameters I, Q, U, representing linear polarisation. In this paper we present results of recent observational campaigns demonstrating the good performance of NIKA in detecting polarisation at mm wavelength.
△ Less
Submitted 7 October, 2015; v1 submitted 4 August, 2015;
originally announced August 2015.
-
High-energy interactions in Kinetic Inductance Detectors arrays
Authors:
A. D'Addabbo,
M. Calvo,
J. Goupy,
A. Benoit,
O. Bourrion,
A. Catalano,
J. F. Macias-Perez,
A. Monfardini
Abstract:
The impacts of Cosmic Rays on the detectors are a key problem for space-based missions. We are studying the effects of such interactions on arrays of Kinetic Inductance Detectors (KID), in order to adapt this technology for use on board of satellites. Before proposing a new technology such as the Kinetic Inductance Detectors for a space-based mission, the problem of the Cosmic Rays that hit the de…
▽ More
The impacts of Cosmic Rays on the detectors are a key problem for space-based missions. We are studying the effects of such interactions on arrays of Kinetic Inductance Detectors (KID), in order to adapt this technology for use on board of satellites. Before proposing a new technology such as the Kinetic Inductance Detectors for a space-based mission, the problem of the Cosmic Rays that hit the detectors during in-flight operation has to be studied in detail. We present here several tests carried out with KID exposed to radioactive sources, which we use to reproduce the physical interactions induced by primary Cosmic Rays, and we report the results obtained adopting different solutions in terms of substrate materials and array geometries. We conclude by outlining the main guidelines to follow for fabricating KID for space-based applications.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
Bi-layer Kinetic Inductance Detectors for space observations between 80-120 GHz
Authors:
A. Catalano,
J. Goupy,
H. le Sueur,
A. Benoit,
O. Bourrion,
M. Calvo,
L. Dumoulin,
F. Levy-Bertrand,
J. Macìas-Pérez,
S. Marnieros,
N. Ponthieu,
A. Monfardini
Abstract:
We have developed Lumped Element Kinetic Inductance Detectors (LEKID) sensitive in the frequency band from 80 to 120~GHz. In this work, we take advantage of the so-called proximity effect to reduce the superconducting gap of Aluminium, otherwise strongly suppressing the LEKID response for frequencies smaller than 100~GHz. We have designed, produced and optically tested various fully multiplexed ar…
▽ More
We have developed Lumped Element Kinetic Inductance Detectors (LEKID) sensitive in the frequency band from 80 to 120~GHz. In this work, we take advantage of the so-called proximity effect to reduce the superconducting gap of Aluminium, otherwise strongly suppressing the LEKID response for frequencies smaller than 100~GHz. We have designed, produced and optically tested various fully multiplexed arrays based on multi-layers combinations of Aluminium (Al) and Titanium (Ti). Their sensitivities have been measured using a dedicated closed-circle 100 mK dilution cryostat and a sky simulator allowing to reproduce realistic observation conditions. The spectral response has been characterised with a Martin-Puplett interferometer up to THz frequencies, and with a resolution of 3~GHz. We demonstrate that Ti-Al LEKID can reach an optical sensitivity of about $1.4$ $10^{-17}$~$W/Hz^{0.5}$ (best pixel), or $2.2$ $10^{-17}$~$W/Hz^{0.5}$ when averaged over the whole array. The optical background was set to roughly 0.4~pW per pixel, typical for future space observatories in this particular band. The performance is close to a sensitivity of twice the CMB photon noise limit at 100~GHz which drove the design of the Planck HFI instrument. This figure remains the baseline for the next generation of millimetre-wave space satellites.
△ Less
Submitted 1 April, 2015;
originally announced April 2015.
-
Pressure distribution of the high-redshift cluster of galaxies CL J1226.9+3332 with NIKA
Authors:
R. Adam,
B. Comis,
J. -F. Macías-Pérez,
A. Adane,
P. Ade,
P. André,
A. Beelen,
B. Belier,
A. Benoît,
A. Bideaud,
N. Billot,
G. Blanquer,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
A. Cruciani,
A. D'Addabbo,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. Martino,
P. Mauskopf
, et al. (15 additional authors not shown)
Abstract:
The thermal Sunyaev-Zel'dovich (tSZ) effect is expected to provide a low scatter mass proxy for galaxy clusters since it is directly proportional to the cluster thermal energy. The tSZ observations have proven to be a powerful tool for detecting and studying them, but high angular resolution observations are now needed to push their investigation to a higher redshift. In this paper, we report high…
▽ More
The thermal Sunyaev-Zel'dovich (tSZ) effect is expected to provide a low scatter mass proxy for galaxy clusters since it is directly proportional to the cluster thermal energy. The tSZ observations have proven to be a powerful tool for detecting and studying them, but high angular resolution observations are now needed to push their investigation to a higher redshift. In this paper, we report high angular (< 20 arcsec) resolution tSZ observations of the high-redshift cluster CL J1226.9+3332 (z=0.89). It was imaged at 150 and 260 GHz using the NIKA camera at the IRAM 30-meter telescope. The 150 GHz map shows that CL J1226.9+3332 is morphologically relaxed on large scales with evidence of a disturbed core, while the 260 GHz channel is used mostly to identify point source contamination. NIKA data are combined with those of Planck and X-ray from Chandra to infer the cluster's radial pressure, density, temperature, and entropy distributions. The total mass profile of the cluster is derived, and we find $M_{500} = 5.96^{+1.02}_{-0.79} $ x $10^{14} M_{\odot}$ within the radius $R_{500} = 930^{+50}_{-43}$ kpc, at a 68% confidence level. ($R_{500}$ is the radius within which the average density is 500 times the critical density at the cluster's redshift.) NIKA is the prototype camera of NIKA2, a KIDs (kinetic inductance detectors) based instrument to be installed at the end of 2015. This work is, therefore, part of a pilot study aiming at optimizing tSZ NIKA2 large programs.
△ Less
Submitted 15 May, 2015; v1 submitted 10 October, 2014;
originally announced October 2014.
-
High resolution SZ observations at the IRAM 30-m telescope with NIKA
Authors:
R. Adam,
A. Adane,
P. Ade,
P. Andrée,
A. Beelen,
B. Belier,
A. Benoît,
A. Bideaud,
N. Billot,
N. Boudou,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
B. Comis,
A. D'Addabbo,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. F. Macías-Pérez,
J. Martino,
P. Mauskopf,
F. Mayet
, et al. (14 additional authors not shown)
Abstract:
High resolution observations of the thermal Sunyaev-Zel'dovich (tSZ) effect are necessary to allow the use of clusters of galaxies as a probe for large scale structures at high redshifts. With its high resolution and dual-band capability at millimeter wavelengths, the NIKA camera can play a significant role in this context. NIKA is based on newly developed Kinetic Inductance Detectors (KIDs) and o…
▽ More
High resolution observations of the thermal Sunyaev-Zel'dovich (tSZ) effect are necessary to allow the use of clusters of galaxies as a probe for large scale structures at high redshifts. With its high resolution and dual-band capability at millimeter wavelengths, the NIKA camera can play a significant role in this context. NIKA is based on newly developed Kinetic Inductance Detectors (KIDs) and operates at the IRAM 30m telescope, Pico Veleta, Spain. In this paper, we give the status of the NIKA camera, focussing on the KID technology. We then present observations of three galaxy clusters: RX J1347.5-1145 as a demonstrator of the NIKA capabilities and the recent observations of CL J1226.9+3332 (z = 0.89) and MACS J0717.5+3745 (z = 0.55). We also discuss prospects for the final NIKA2 camera, which will have a 6.5 arcminute field of view with about 5000 detectors in two bands at 150 and 260 GHz.
△ Less
Submitted 3 September, 2014;
originally announced September 2014.
-
The NIKA 2012-2014 observing campaigns: control of systematic effects and results
Authors:
A. Catalano,
R. Adam,
A. Adane,
P. Ade,
P. André,
A. Beelen,
B. Belier,
A. Benôit,
A. Bideaud,
N. Billot,
N. Boudou,
O. Bourrion,
M. Calvo,
G. Coiffard,
B. Comis,
A. D'Addabbo,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. F. Macías-Pérez,
J. Martino,
P. Mauskopf,
F. Mayet
, et al. (13 additional authors not shown)
Abstract:
The New IRAM KID Array (NIKA) is a dual-band camera operating with frequency multiplexed arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs) cooled to 100 mK. NIKA is designed to observe the intensity and polarisation of the sky at 1.25 and 2.14 mm from the IRAM 30 m telescope. We present the improvements on the control of systematic effects and astrophysical results made during the las…
▽ More
The New IRAM KID Array (NIKA) is a dual-band camera operating with frequency multiplexed arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs) cooled to 100 mK. NIKA is designed to observe the intensity and polarisation of the sky at 1.25 and 2.14 mm from the IRAM 30 m telescope. We present the improvements on the control of systematic effects and astrophysical results made during the last observation campaigns between 2012 and 2014.
△ Less
Submitted 2 September, 2014;
originally announced September 2014.
-
Performance and calibration of the NIKA camera at the IRAM 30 m telescope
Authors:
A. Catalano,
M. Calvo,
N. Ponthieu,
R. Adam,
A. Adane,
P. Ade,
P. Andre,
A. Beelen,
B. Belier,
A. Benoit,
A. Bideaud,
N. Billot,
N. Boudou,
O. Bourrion,
G. Coiffard,
B. Comis,
A. D'Addabbo,
F. -X. Desert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. F. Macias-Perez,
J. Martino,
P. Mauskopf
, et al. (12 additional authors not shown)
Abstract:
The New IRAM KID Array (NIKA) instrument is a dual-band imaging camera operating with Kinetic Inductance Detectors (KID) cooled at 100 mK. NIKA is designed to observe the sky at wavelengths of 1.25 and 2.14 mm from the IRAM 30 m telescope at Pico Veleta with an estimated resolution of 13\,arcsec and 18 arcsec, respectively. This work presents the performance of the NIKA camera prior to its opening…
▽ More
The New IRAM KID Array (NIKA) instrument is a dual-band imaging camera operating with Kinetic Inductance Detectors (KID) cooled at 100 mK. NIKA is designed to observe the sky at wavelengths of 1.25 and 2.14 mm from the IRAM 30 m telescope at Pico Veleta with an estimated resolution of 13\,arcsec and 18 arcsec, respectively. This work presents the performance of the NIKA camera prior to its opening to the astrophysical community as an IRAM common-user facility in early 2014. NIKA is a test bench for the final NIKA2 instrument to be installed at the end of 2015. The last NIKA observation campaigns on November 2012 and June 2013 have been used to evaluate this performance and to improve the control of systematic effects. We discuss here the dynamical tuning of the readout electronics to optimize the KID working point with respect to background changes and the new technique of atmospheric absorption correction. These modifications significantly improve the overall linearity, sensitivity, and absolute calibration performance of NIKA. This is proved on observations of point-like sources for which we obtain a best sensitivity (averaged over all valid detectors) of 40 and 14 mJy.s$^{1/2}$ for optimal weather conditions for the 1.25 and 2.14 mm arrays, respectively. NIKA observations of well known extended sources (DR21 complex and the Horsehead nebula) are presented. This performance makes the NIKA camera a competitive astrophysical instrument.
△ Less
Submitted 2 September, 2014; v1 submitted 2 February, 2014;
originally announced February 2014.
-
The NIKA instrument: results and perspectives towards a permanent KID based camera for the Pico Veleta observatory
Authors:
A. D'Addabbo,
R. Adam,
A. Adane,
P. Ade,
P. André,
A. Beelen,
B. Belier,
A. Benoit,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
B. Comis,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. Macias-Perez,
J. Martino,
P. Mauskopf,
F. Mayet,
A. Monfardini
, et al. (10 additional authors not shown)
Abstract:
The New IRAM KIDs Array (NIKA) is a pathfinder instrument devoted to millimetric astronomy. In 2009 it was the first multiplexed KID camera on the sky; currently it is installed at the focal plane of the IRAM 30-meters telescope at Pico Veleta (Spain). We present preliminary data from the last observational run and the ongoing developments devoted to the next NIKA-2 kilopixels camera, to be commis…
▽ More
The New IRAM KIDs Array (NIKA) is a pathfinder instrument devoted to millimetric astronomy. In 2009 it was the first multiplexed KID camera on the sky; currently it is installed at the focal plane of the IRAM 30-meters telescope at Pico Veleta (Spain). We present preliminary data from the last observational run and the ongoing developments devoted to the next NIKA-2 kilopixels camera, to be commissioned in 2015. We also report on the latest laboratory measurements, and recent improvements in detector cosmetics and read-out electronics. Furthermore, we describe a new acquisition strategy allowing us to improve the photometric accuracy, and the related automatic tuning procedure.
△ Less
Submitted 17 December, 2013;
originally announced December 2013.
-
Niobium Silicon alloys for Kinetic Inductance Detectors
Authors:
M. Calvo,
A. D'Addabbo,
A. Monfardini,
A. Benoit,
N. Boudou,
O. Bourrion,
A. Catalano,
L. Dumoulin,
J. Goupy,
H. Le Sueur,
S. Marnieros
Abstract:
We are studying the properties of Niobium Silicon amorphous alloys as a candidate material for the fabrication of highly sensitive Kinetic Inductance Detectors (KID), optimized for very low optical loads. As in the case of other composite materials, the NbSi properties can be changed by varying the relative amounts of its components. Using a NbSi film with T_c around 1 K we have been able to obtai…
▽ More
We are studying the properties of Niobium Silicon amorphous alloys as a candidate material for the fabrication of highly sensitive Kinetic Inductance Detectors (KID), optimized for very low optical loads. As in the case of other composite materials, the NbSi properties can be changed by varying the relative amounts of its components. Using a NbSi film with T_c around 1 K we have been able to obtain the first NbSi resonators, observe an optical response and acquire a spectrum in the band 50 to 300 GHz. The data taken show that this material has very high kinetic inductance and normal state surface resistivity. These properties are ideal for the development of KID. More measurements are planned to further characterize the NbSi alloy and fully investigate its potential.
△ Less
Submitted 12 December, 2013;
originally announced December 2013.
-
Detection of the tSZ effect with the NIKA camera
Authors:
B. Comis,
R. Adam,
J. F. Macías-Pérez,
A. Adane,
P. Ade,
P. André,
A. Beelen,
B. Belier,
A. Benoît,
A. Bideaud,
N. Billot,
N. Boudou,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
A. D'Addabbo,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. Martino,
P. Mauskopf,
F. Mayet
, et al. (13 additional authors not shown)
Abstract:
We present the first detection of the thermal Sunyaev-Zel'dovich (tSZ) effect from a cluster of galaxies performed with a KIDs (Kinetic Inductance Detectors) based instrument. The tSZ effect is a distortion of the black body CMB (Cosmic Microwave Background) spectrum produced by the inverse Compton interaction of CMB photons with the hot electrons of the ionized intra-cluster medium. The massive,…
▽ More
We present the first detection of the thermal Sunyaev-Zel'dovich (tSZ) effect from a cluster of galaxies performed with a KIDs (Kinetic Inductance Detectors) based instrument. The tSZ effect is a distortion of the black body CMB (Cosmic Microwave Background) spectrum produced by the inverse Compton interaction of CMB photons with the hot electrons of the ionized intra-cluster medium. The massive, intermediate redshift cluster RX J1347.5-1145 has been observed using NIKA (New IRAM KIDs arrays), a dual-band (140 and 240 GHz) mm-wave imaging camera, which exploits two arrays of hundreds of KIDs: the resonant frequencies of the superconducting resonators are shifted by mm-wave photons absorption. This tSZ cluster observation demonstrates the potential of the next generation NIKA2 instrument, being developed for the 30m telescope of IRAM, at Pico Veleta (Spain). NIKA2 will have 1000 detectors at 140GHz and 2x2000 detectors at 240GHz, providing in that band also a measurement of the linear polarization. NIKA2 will be commissioned in 2015.
△ Less
Submitted 10 December, 2013;
originally announced December 2013.
-
First observation of the thermal Sunyaev-Zel'dovich effect with kinetic inductance detectors
Authors:
R. Adam,
B. Comis,
J. F. Macías-Pérez,
A. Adane,
P. Ade,
P. André,
A. Beelen,
B. Belier,
A. Benoît,
A. Bideaud,
N. Billot,
N. Boudou,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
A. D'Addabbo,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. Martino,
P. Mauskopf,
F. Mayet
, et al. (13 additional authors not shown)
Abstract:
Clusters of galaxies provide valuable information on the evolution of the Universe and large scale structures. Recent cluster observations via the thermal Sunyaev-Zel'dovich (tSZ) effect have proven to be a powerful tool to detect and study them. In this context, high resolution tSZ observations (~ tens of arcsec) are of particular interest to probe intermediate and high redshift clusters. Observa…
▽ More
Clusters of galaxies provide valuable information on the evolution of the Universe and large scale structures. Recent cluster observations via the thermal Sunyaev-Zel'dovich (tSZ) effect have proven to be a powerful tool to detect and study them. In this context, high resolution tSZ observations (~ tens of arcsec) are of particular interest to probe intermediate and high redshift clusters. Observations of the tSZ effect will be carried out with the millimeter dual-band NIKA2 camera, based on Kinetic Inductance Detectors (KIDs) to be installed at the IRAM 30-meter telescope in 2015. To demonstrate the potential of such an instrument, we present tSZ observations with the NIKA camera prototype, consisting of two arrays of 132 and 224 detectors that observe at 140 and 240 GHz with a 18.5 and 12.5 arcsec angular resolution, respectively. The cluster RX J1347.5-1145 was observed simultaneously at 140 and 240 GHz. We used a spectral decorrelation technique to remove the atmospheric noise and obtain a map of the cluster at 140 GHz. The efficiency of this procedure has been characterized through realistic simulations of the observations. The observed 140 GHz map presents a decrement at the cluster position consistent with the tSZ nature of the signal. We used this map to study the pressure distribution of the cluster by fitting a gNFW model to the data. Subtracting this model from the map, we confirm that RX J1347.5-1145 is an ongoing merger, which confirms and complements previous tSZ and X-ray observations. For the first time, we demonstrate the tSZ capability of KID based instruments. The NIKA2 camera with ~ 5000 detectors and a 6.5 arcmin field of view will be well-suited for in-depth studies of the intra cluster medium in intermediate to high redshifts, which enables the characterization of recently detected clusters by the Planck satellite.
△ Less
Submitted 3 September, 2014; v1 submitted 23 October, 2013;
originally announced October 2013.
-
High speed readout electronics development for frequency-multiplexed kinetic inductance detector design optimization
Authors:
O. Bourrion,
C. Vescovi,
A. Catalano,
M. Calvo,
A. D'Addabbo,
J. Goupy,
N. Boudou,
J. F. Macias-Perez,
A. Monfardini
Abstract:
Microwave Kinetic Inductance Detectors (MKID) are a promising solution for spaceborne mm-wave astronomy. To optimize their design and make them insensitive to the ballistic phonons created by cosmic-ray interactions in the substrate, the phonon propagation in silicon must be studied. A dedicated fast readout electronics, using channelized Digital Down Conversion for monitoring up to 12 MKIDs over…
▽ More
Microwave Kinetic Inductance Detectors (MKID) are a promising solution for spaceborne mm-wave astronomy. To optimize their design and make them insensitive to the ballistic phonons created by cosmic-ray interactions in the substrate, the phonon propagation in silicon must be studied. A dedicated fast readout electronics, using channelized Digital Down Conversion for monitoring up to 12 MKIDs over a 100MHz bandwidth was developed. Thanks to the fast ADC sampling and steep digital filtering, In-phase and Quadrature samples, having a high dynamic range, are provided at ~2 Msps. This paper describes the technical solution chosen and the results obtained.
△ Less
Submitted 12 November, 2013; v1 submitted 22 October, 2013;
originally announced October 2013.
-
Latest NIKA results and the NIKA-2 project
Authors:
A. Monfardini,
R. Adam,
A. Adane,
P. Ade,
P. André,
A. Beelen,
B. Belier,
A. Benoit,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
A. Catalano,
G. Coiffard,
B. Comis,
A. D'Addabbo,
F. -X. Désert,
S. Doyle,
J. Goupy,
C. Kramer,
S. Leclercq,
J. Macias-Perez,
J. Martino,
P. Mauskopf,
F. Mayet
, et al. (10 additional authors not shown)
Abstract:
NIKA (New IRAM KID Arrays) is a dual-band imaging instrument installed at the IRAM (Institut de RadioAstronomie Millimetrique) 30-meter telescope at Pico Veleta (Spain). Two distinct Kinetic Inductance Detectors (KID) focal planes allow the camera to simultaneously image a field-of-view of about 2 arc-min in the bands 125 to 175 GHz (150 GHz) and 200 to 280 GHz (240 GHz). The sensitivity and stabi…
▽ More
NIKA (New IRAM KID Arrays) is a dual-band imaging instrument installed at the IRAM (Institut de RadioAstronomie Millimetrique) 30-meter telescope at Pico Veleta (Spain). Two distinct Kinetic Inductance Detectors (KID) focal planes allow the camera to simultaneously image a field-of-view of about 2 arc-min in the bands 125 to 175 GHz (150 GHz) and 200 to 280 GHz (240 GHz). The sensitivity and stability achieved during the last commissioning Run in June 2013 allows opening the instrument to general observers. We report here the latest results, in particular in terms of sensitivity, now comparable to the state-of-the-art Transition Edge Sensors (TES) bolometers, relative and absolute photometry. We describe briefly the next generation NIKA-2 instrument, selected by IRAM to occupy, from 2015, the continuum imager/polarimeter slot at the 30-m telescope.
△ Less
Submitted 10 September, 2014; v1 submitted 4 October, 2013;
originally announced October 2013.