-
BLAST: Resolving the Cosmic Submillimeter Background
Authors:
Gaelen Marsden,
Peter A. R. Ade,
James J. Bock,
Edward L. Chapin,
Mark J. Devlin,
Simon R. Dicker,
Matthew Griffin,
Joshua O. Gundersen,
Mark Halpern,
Peter C. Hargrave,
David H. Hughes,
Jeff Klein,
Philip Mauskopf,
Benjamin Magnelli,
Lorenzo Moncelsi,
Calvin B. Netterfield,
Henry Ngo,
Luca Olmi,
Enzo Pascale,
Guillaume Patanchon,
Marie Rex,
Douglas Scott,
Christopher Semisch,
Nicholas Thomas,
Matthew D. P. Truch
, et al. (4 additional authors not shown)
Abstract:
The Balloon-borne Large Aperture Submillimeter Telescope (BLAST) has made one square degree, deep, confusion limited maps at three different bands, centered on the Great Observatories Origins Deep Survey South field. By calculating the covariance of these maps with catalogs of 24 micron sources from the Far-Infrared Deep Extragalactic Legacy Survey (FIDEL), we have determined that the total subm…
▽ More
The Balloon-borne Large Aperture Submillimeter Telescope (BLAST) has made one square degree, deep, confusion limited maps at three different bands, centered on the Great Observatories Origins Deep Survey South field. By calculating the covariance of these maps with catalogs of 24 micron sources from the Far-Infrared Deep Extragalactic Legacy Survey (FIDEL), we have determined that the total submillimeter intensities are 8.60 +/- 0.59, 4.93 +/- 0.34, and 2.27 +/- 0.20 nW m^2 sr^(-1) at 250, 350, and 500 micron, respectively. These numbers are more precise than previous estimates of the cosmic infrared background (CIB) and are consistent with 24 micron-selected galaxies generating the full intensity of the CIB.
We find that the fraction of the CIB that originates from sources at z >= 1.2 increases with wavelength, with 60% from high redshift sources at 500 micron. At all BLAST wavelengths, the relative intensity of high-z sources is higher for 24 micron-faint sources than it is for 24 micron-bright sources. Galaxies identified as active galactic nuclei (AGN) by their Infrared Array Camera (IRAC) colors are 1.6-2.6 times brighter than the average population at 250-500 micron, consistent with what is found for X-ray-selected AGN. BzK-selected galaxies are found to be moderately brighter than typical 24 micron-selected galaxies in the BLAST bands. These data provide high precision constraints for models of the evolution of the number density and intensity of star forming galaxies at high redshift.
△ Less
Submitted 25 September, 2009; v1 submitted 8 April, 2009;
originally announced April 2009.
-
A Bright Submillimeter Source in the Bullet Cluster (1E0657--56) Field Detected with BLAST
Authors:
Marie Rex,
Peter A. R. Ade,
Itziar Aretxaga,
James J. Bock,
Edward L. Chapin,
Mark J. Devlin,
Simon R. Dicker,
Matthew Griffin,
Joshua O. Gundersen,
Mark Halpern,
Peter C. Hargrave,
David H. Hughes,
Jeff Klein,
Gaelen Marsden,
Peter G. Martin,
Philip Mauskopf,
Alfredo Montana,
Calvin B. Netterfield,
Luca Olmi,
Enzo Pascale,
Guillaume Patanchon,
Douglas Scott,
Christopher Semisch,
Nicholas Thomas,
Matthew D. P. Truch
, et al. (4 additional authors not shown)
Abstract:
We present the 250, 350, and 500 micron detection of bright submillimeter emission in the direction of the Bullet Cluster measured by the Balloon-borne Large Aperture Submillimeter Telescope (BLAST). The 500 micron centroid is coincident with an AzTEC 1.1 mm point-source detection at a position close to the peak lensing magnification produced by the cluster. However, the 250 micron and 350 micro…
▽ More
We present the 250, 350, and 500 micron detection of bright submillimeter emission in the direction of the Bullet Cluster measured by the Balloon-borne Large Aperture Submillimeter Telescope (BLAST). The 500 micron centroid is coincident with an AzTEC 1.1 mm point-source detection at a position close to the peak lensing magnification produced by the cluster. However, the 250 micron and 350 micron centroids are elongated and shifted toward the south with a differential shift between bands that cannot be explained by pointing uncertainties. We therefore conclude that the BLAST detection is likely contaminated by emission from foreground galaxies associated with the Bullet Cluster. The submillimeter redshift estimate based on 250-1100 micron photometry at the position of the AzTEC source is z_phot = 2.9 (+0.6 -0.3), consistent with the infrared color redshift estimation of the most likely IRAC counterpart. These flux densities indicate an apparent far-infrared luminosity of L_FIR = 2E13 Lsun. When the amplification due to the gravitational lensing of the cluster is removed, the intrinsic far-infrared luminosity of the source is found to be L_FIR <= 10^12 Lsun, consistent with typical luminous infrared galaxies.
△ Less
Submitted 25 September, 2009; v1 submitted 8 April, 2009;
originally announced April 2009.
-
The Balloon-borne Large Aperture Submillimeter Telescope (BLAST) 2006: Calibration and Flight Performance
Authors:
Matthew D. P. Truch,
Peter A. R. Ade,
James J. Bock,
Edward L. Chapin,
Mark J. Devlin,
Simon R. Dicker,
Matthew Griffin,
Joshua O. Gundersen,
Mark Halpern,
Peter C. Hargrave,
David H. Hughes,
Jeff Klein,
Gaelen Marsden,
Peter G. Martin,
Philip Mauskopf,
Lorenzo Moncelsi,
Calvin B. Netterfield,
Luca Olmi,
Enzo Pascale,
Guillaume Patanchon,
Marie Rex,
Douglas Scott,
Christopher Semisch,
Nicholas E. Thomas,
Carole Tucker
, et al. (3 additional authors not shown)
Abstract:
The Balloon-borne Large Aperture Submillimeter Telescope (BLAST) operated successfully during a 250-hour flight over Antarctica in December 2006 (BLAST06). As part of the calibration and pointing procedures, the red hypergiant star VY CMa was observed and used as the primary calibrator. Details of the overall BLAST06 calibration procedure are discussed. The 1-sigma absolute calibration is accura…
▽ More
The Balloon-borne Large Aperture Submillimeter Telescope (BLAST) operated successfully during a 250-hour flight over Antarctica in December 2006 (BLAST06). As part of the calibration and pointing procedures, the red hypergiant star VY CMa was observed and used as the primary calibrator. Details of the overall BLAST06 calibration procedure are discussed. The 1-sigma absolute calibration is accurate to 10, 12, and 13% at the 250, 350, and 500 micron bands, respectively. The errors are highly correlated between bands resulting in much lower error for the derived shape of the 250-500 micron continuum. The overall pointing error is <5" rms for the 36, 42, and 60" beams. The performance of the optics and pointing systems is discussed.
△ Less
Submitted 25 September, 2009; v1 submitted 8 April, 2009;
originally announced April 2009.
-
Optical Design of the Atacama Cosmology Telescope and the Millimeter Bolometric Array Camera
Authors:
J. W. Fowler,
M. D. Niemack,
S. R. Dicker,
A. M. Aboobaker,
P. A. R. Ade,
E. S. Battistelli,
M. J. Devlin,
R. P. Fisher,
M. Halpern,
P. C. Hargrave,
A. D. Hincks,
M. Kaul,
J. Klein,
J. M. Lau,
M. Limon,
T. A. Marriage,
P. D. Mauskopf,
L. Page,
S. T. Staggs,
D. S. Swetz,
E. R. Switzer,
R. J. Thornton,
C. E. Tucker
Abstract:
The Atacama Cosmology Telescope is a 6-meter telescope designed to map the Cosmic Microwave Background simultaneously at 145 GHz, 215 GHz, and 280 GHz with arcminute resolution. Each frequency will have a 32 by 32 element focal plane array of TES bolometers. This paper describes the design of the telescope and the cold reimaging optics, which is optimized for millimeter-wave observations with th…
▽ More
The Atacama Cosmology Telescope is a 6-meter telescope designed to map the Cosmic Microwave Background simultaneously at 145 GHz, 215 GHz, and 280 GHz with arcminute resolution. Each frequency will have a 32 by 32 element focal plane array of TES bolometers. This paper describes the design of the telescope and the cold reimaging optics, which is optimized for millimeter-wave observations with these sensitive detectors.
△ Less
Submitted 2 February, 2007; v1 submitted 31 December, 2006;
originally announced January 2007.
-
CMB observations with the Jodrell Bank - IAC interferometer at 33 GHz
Authors:
S. R. Dicker,
S. J. Melhuish,
R. D. Davies,
C. M. Gutierrez,
R. Rebolo,
D. L. Harrison,
R. J. Davis,
A. Wilkinson,
R. J. Hoyland,
R. A. Watson
Abstract:
The paper presents the first results obtained with the Jodrell Bank - IAC two-element 33 GHz interferometer. The instrument was designed to measure the level of the Cosmic Microwave Background (CMB) fluctuations at angular scales of 1 - 2 degrees. The observations analyzed here were taken in a strip of the sky at Dec = +41 deg with an element separation of 16.7 lambda, which gives a maximum sens…
▽ More
The paper presents the first results obtained with the Jodrell Bank - IAC two-element 33 GHz interferometer. The instrument was designed to measure the level of the Cosmic Microwave Background (CMB) fluctuations at angular scales of 1 - 2 degrees. The observations analyzed here were taken in a strip of the sky at Dec = +41 deg with an element separation of 16.7 lambda, which gives a maximum sensitivity to ~1.6 deg structures on the sky. The data processing and calibration of the instrument are described. The sensitivity achieved in each of the two channels is 7 micro K per resolution element. A reconstruction of the sky at Dec = +41 deg using a maximum entropy method shows the presence of structure at a high level of significance. A likelihood analysis, assuming a flat CMB spatial power spectrum, gives a best estimate of the level of CMB fluctuations of Delta Tl = 43 (+13,-12) micro K for the range l = 109 +/- 19; the main uncertainty in this result arises from sample variance. We consider that the contamination from the Galaxy is small. These results represent a new determination of the CMB power spectrum on angular scales where previous results show a large scatter; our new results are in agreement with the theoretical predictions of the standard inflationary cold dark matter models.
△ Less
Submitted 9 July, 1999;
originally announced July 1999.