-
QUBIC Technical Design Report
Authors:
J. Aumont,
S. Banfi,
P. Battaglia,
E. S. Battistelli,
A. Baù,
B. Bélier,
D. Bennett,
L. Bergé,
J. Ph. Bernard,
M. Bersanelli,
M. A. Bigot-Sazy,
N. Bleurvacq,
G. Bordier,
J. Brossard,
E. F. Bunn,
D. Buzi,
A. Buzzelli,
D. Cammilleri,
F. Cavaliere,
P. Chanial,
C. Chapron,
G. Coppi,
A. Coppolecchia,
F. Couchot,
R. D'Agostino
, et al. (74 additional authors not shown)
Abstract:
QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticip…
▽ More
QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticipated polarized foregrounds (dust) reducing to zero the initial hope of finding sky regions clean enough to have a direct primordial B-modes observation. The QUBIC instrument is designed to address all aspects of this challenge with a novel kind of instrument, a Bolometric Interferometer, combining the background-limited sensitivity of Transition-Edge-Sensors and the control of systematics allowed by the observation of interference fringe patterns, while operating at two frequencies to disentangle polarized foregrounds from primordial B mode polarization. Its characteristics are described in details in this Technological Design Report.
△ Less
Submitted 11 May, 2017; v1 submitted 14 September, 2016;
originally announced September 2016.
-
New application of superconductors: high sensitivity cryogenic light detectors
Authors:
L. Cardani,
F. Bellini,
N. Casali,
M. G. Casellano,
I. Colantoni,
A. Coppolecchia,
C. Cosmelli,
A. Cruciani,
A. D'Addabbo,
S. Di Domizio,
M. Martinez,
C. Tomei,
M. Vignati
Abstract:
In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superc…
▽ More
In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs), that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2x2 cm2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.
△ Less
Submitted 12 April, 2016;
originally announced April 2016.
-
Development of Lumped Element Kinetic Inductance Detectors for the W-Band
Authors:
A. Paiella,
A. Coppolecchia,
M. G. Castellano,
I. Colantoni,
A. Cruciani,
A. D'Addabbo,
P. de Bernardis,
S. Masi,
G. Presta
Abstract:
We are developing a Lumped Element Kinetic Inductance Detector (LEKID) array able to operate in the W-band (75-110 GHz) in order to perform ground-based Cosmic Microwave Background (CMB) and mm-wave astronomical observations. The W-band is close to optimal in terms of contamination of the CMB from Galactic synchrotron, free-free, and thermal interstellar dust. In this band, the atmosphere has very…
▽ More
We are developing a Lumped Element Kinetic Inductance Detector (LEKID) array able to operate in the W-band (75-110 GHz) in order to perform ground-based Cosmic Microwave Background (CMB) and mm-wave astronomical observations. The W-band is close to optimal in terms of contamination of the CMB from Galactic synchrotron, free-free, and thermal interstellar dust. In this band, the atmosphere has very good transparency, allowing interesting ground-based observations with large (>30 m) telescopes, achieving high angular resolution (<0.4 arcmin). In this work we describe the startup measurements devoted to the optimization of a W-band camera/spectrometer prototype for large aperture telescopes like the 64 m SRT (Sardinia Radio Telescope). In the process of selecting the best superconducting film for the LEKID, we characterized a 40 nm thick Aluminum 2-pixel array. We measured the minimum frequency able to break CPs (i.e. $hν=2Δ\left(T_{c}\right)=3.5k_{B}T_{c}$) obtaining $ν=95.5$ GHz, that corresponds to a critical temperature of 1.31 K. This is not suitable to cover the entire W-band. For an 80 nm layer the minimum frequency decreases to 93.2 GHz, which corresponds to a critical temperature of 1.28 K; this value is still suboptimal for W-band operation. Further increase of the Al film thickness results in bad performance of the detector. We have thus considered a Titanium-Aluminum bi-layer (10 nm thick Ti + 25 nm thick Al, already tested in other laboratories), for which we measured a critical temperature of 820 mK and a cut-on frequency of 65 GHz: so this solution allows operation in the entire W-band.
△ Less
Submitted 7 January, 2016;
originally announced January 2016.
-
CALDER: cryogenic light detector for rare events search
Authors:
L. Pagnanini,
E. S. Battistelli,
F. Bellini,
M. Calvo,
L. Cardani,
N. Casali,
M. G. Castellano,
I. Colantoni,
A. Coppolecchia,
C. Cosmelli,
A. Cruciani,
P. De Bernardis,
S. Di Domizio,
A. D'Addabbo,
M. Martinez,
S. Masi,
C. Tomei,
M. Vignati
Abstract:
The CALDER project aims at developing cryogenic light detectors with high sensitivity to UV and visible light, to be used for particle tagging in massive bolometers. Indeed the sensitivity of CUORE can be increased by a factor of 3, thanks to the reduction of the $α$-background, obtained by detecting the Cherenkov light (100 eV) emitted by $β/γ$ events. Currently used light detectors have not the…
▽ More
The CALDER project aims at developing cryogenic light detectors with high sensitivity to UV and visible light, to be used for particle tagging in massive bolometers. Indeed the sensitivity of CUORE can be increased by a factor of 3, thanks to the reduction of the $α$-background, obtained by detecting the Cherenkov light (100 eV) emitted by $β/γ$ events. Currently used light detectors have not the features required to address this task, so we decided to develop a new light detector using Kinetic Inductance Detector as a sensor. This approach is very challenging and requires an intensive R$\&$D to be satisfied. The first results of this activity are shown in the following.
△ Less
Submitted 30 December, 2015;
originally announced December 2015.
-
Characterization of the KID-Based Light Detectors of CALDER
Authors:
N. Casali,
F. Bellini,
L. Cardani,
M. G. Castellano,
I. Colantoni,
A. Coppolecchia,
C. Cosmelli,
A. Cruciani,
A. D'Addabbo,
S. Di Domizio,
M. Martinez,
C. Tomei,
M. Vignati
Abstract:
The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution (CALDER) project is the development of light detectors with active area of $5\times5$ cm$^2$ and noise energy resolution smaller than 20 eV RMS, implementing phonon-mediated kinetic inductance detectors. The detectors are developed to improve the background suppression in large-mass bolometric experiments such as CUORE, v…
▽ More
The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution (CALDER) project is the development of light detectors with active area of $5\times5$ cm$^2$ and noise energy resolution smaller than 20 eV RMS, implementing phonon-mediated kinetic inductance detectors. The detectors are developed to improve the background suppression in large-mass bolometric experiments such as CUORE, via the double read-out of the light and the heat released by particles interacting in the bolometers. In this work, we present the characterization of the first light detectors developed by CALDER. We describe the analysis tools to evaluate the resonator parameters (resonant frequency and quality factors) taking into account simultaneously all the resonance distortions introduced by the read-out chain (as the feed-line impedance and its mismatch) and by the power stored in the resonator itself. We detail the method for the selection of the optimal point for the detector operation (maximizing the signal-to-noise ratio). Finally, we present the response of the detector to optical pulses in the energy range of 0-30 keV.
△ Less
Submitted 17 November, 2015; v1 submitted 16 November, 2015;
originally announced November 2015.
-
Energy resolution and efficiency of phonon-mediated Kinetic Inductance Detectors for light detection
Authors:
L. Cardani,
I. Colantoni,
A. Cruciani,
S. Di Domizio,
M. Vignati,
F. Bellini,
N. Casali,
M. G. Castellano,
A. Coppolecchia,
C. Cosmelli,
C. Tomei
Abstract:
The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and the natural multiplexed read-out, Kinetic Inductance Detectors (KIDs) are particularly suitable for this purpose. To efficiently couple KIDs-based light detecto…
▽ More
The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and the natural multiplexed read-out, Kinetic Inductance Detectors (KIDs) are particularly suitable for this purpose. To efficiently couple KIDs-based light detectors to the large crystals used by the most advanced bolometric detectors, active surfaces of several cm$^2$ are needed. For this reason, we are developing phonon-mediated detectors. In this paper we present the results obtained with a prototype consisting of four 40 nm thick aluminum resonators patterned on a 2$\times$2 cm$^2$ silicon chip, and calibrated with optical pulses and X-rays. The detector features a noise resolution $σ_E=154\pm7$ eV and an (18$\pm$2)$\%$ efficiency.
△ Less
Submitted 14 September, 2015; v1 submitted 18 May, 2015;
originally announced May 2015.
-
CALDER - Neutrinoless double-beta decay identification in TeO$_2$ bolometers with kinetic inductance detectors
Authors:
E. S. Battistelli,
F. Bellini,
C. Bucci,
M. Calvo,
L. Cardani,
N. Casali,
M. G. Castellano,
I. Colantoni,
A Coppolecchia,
C. Cosmelli,
A. Cruciani,
P. de Bernardis,
S. Di Domizio,
A. D'Addabbo,
M. Martinez,
S. Masi,
L. Pagnanini,
C. Tomei,
M. Vignati
Abstract:
Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE, an array of 988 TeO$_2$ bolometers being commissioned at Laboratori Nazionali del Gran Sasso in Italy, features an expected sensitivity of 50-130 meV at 90% C.L, that can be improved by removing the background from $α$ radioactivity. This is possible if, i…
▽ More
Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE, an array of 988 TeO$_2$ bolometers being commissioned at Laboratori Nazionali del Gran Sasso in Italy, features an expected sensitivity of 50-130 meV at 90% C.L, that can be improved by removing the background from $α$ radioactivity. This is possible if, in coincidence with the heat release in a bolometer, the Cherenkov light emitted by the $β$ signal is detected. The amount of light detected is so far limited to only 100 eV, requiring low-noise cryogenic light detectors. The CALDER project (Cryogenic wide-Area Light Detectors with Excellent Resolution) aims at developing a small prototype experiment consisting of TeO$_2$ bolometers coupled to new light detectors based on kinetic inductance detectors. The R&D is focused on the light detectors that could be implemented in a next-generation neutrinoless double-beta decay experiment.
△ Less
Submitted 19 May, 2015; v1 submitted 6 May, 2015;
originally announced May 2015.
-
Latest Progress on the QUBIC Instrument
Authors:
A. Ghribi,
J. Aumont,
E. S. Battistelli,
A. Bau,
L. Bergé,
J-Ph. Bernard,
M. Bersanelli,
M-A. Bigot-Sazy,
G. Bordier,
E. T. Bunn,
F. Cavaliere,
P. Chanial,
A. Coppolecchia,
T. Decourcelle,
P. De Bernardis,
M. De Petris,
A-A. Drilien,
L. Dumoulin,
M. C. Falvella,
A. Gault,
M. Gervasi,
M. Giard,
M. Gradziel,
L. Grandsire,
D. Gayer
, et al. (38 additional authors not shown)
Abstract:
QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show t…
▽ More
QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show the latest advances in the development of the architecture and the sub-systems of the first module of this instrument to be deployed in Dome Charlie Concordia base - Antarctica in 2015.
△ Less
Submitted 12 November, 2013; v1 submitted 22 July, 2013;
originally announced July 2013.
-
SWIPE: a bolometric polarimeter for the Large-Scale Polarization Explorer
Authors:
P. de Bernardis,
S. Aiola,
G. Amico,
E. Battistelli,
A. Coppolecchia,
A. Cruciani,
A. D' Addabbo,
G. D' Alessandro,
S. De Gregori,
M. De Petris,
D. Goldie,
R. Gualtieri,
V. Haynes,
L. Lamagna,
B. Maffei,
S. Masi,
F. Nati,
M. Wah Ng,
L. Pagano,
F. Piacentini,
L. Piccirillo,
G. Pisano,
G. Romeo,
M. Salatino,
A. Schillaci
, et al. (2 additional authors not shown)
Abstract:
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components and filters cryogenically cooled below 4K to reduce the background on the detectors. Polarimetry is ac…
▽ More
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components and filters cryogenically cooled below 4K to reduce the background on the detectors. Polarimetry is achieved by means of large rotating half-wave plates and wire-grid polarizers in front of the arrays. The polarization modulator is the first component of the optical chain, reducing significantly the effect of instrumental polarization. In SWIPE we trade angular resolution for sensitivity. The diameter of the entrance pupil of the refractive telescope is 45 cm, while the field optics is optimized to collect tens of modes for each detector, thus boosting the absorbed power. This approach results in a FWHM resolution of 1.8, 1.5, 1.2 degrees at 95, 145, 245 GHz respectively. The expected performance of the three channels is limited by photon noise, resulting in a final sensitivity around 0.1-0.2 uK per beam, for a 13 days survey covering 25% of the sky.
△ Less
Submitted 1 August, 2012;
originally announced August 2012.
-
The Large-Scale Polarization Explorer (LSPE)
Authors:
The LSPE collaboration,
S. Aiola,
G. Amico,
P. Battaglia,
E. Battistelli,
A. Baù,
P. de Bernardis,
M. Bersanelli,
A. Boscaleri,
F. Cavaliere,
A. Coppolecchia,
A. Cruciani,
F. Cuttaia,
A. D' Addabbo,
G. D'Alessandro,
S. De Gregori,
F. Del Torto,
M. De Petris,
L. Fiorineschi,
C. Franceschet,
E. Franceschi,
M. Gervasi,
D. Goldie,
A. Gregorio,
V. Haynes
, et al. (32 additional authors not shown)
Abstract:
The LSPE is a balloon-borne mission aimed at measuring the polarization of the Cosmic Microwave Background (CMB) at large angular scales, and in particular to constrain the curl component of CMB polarization (B-modes) produced by tensor perturbations generated during cosmic inflation, in the very early universe. Its primary target is to improve the limit on the ratio of tensor to scalar perturbati…
▽ More
The LSPE is a balloon-borne mission aimed at measuring the polarization of the Cosmic Microwave Background (CMB) at large angular scales, and in particular to constrain the curl component of CMB polarization (B-modes) produced by tensor perturbations generated during cosmic inflation, in the very early universe. Its primary target is to improve the limit on the ratio of tensor to scalar perturbations amplitudes down to r = 0.03, at 99.7% confidence. A second target is to produce wide maps of foreground polarization generated in our Galaxy by synchrotron emission and interstellar dust emission. These will be important to map Galactic magnetic fields and to study the properties of ionized gas and of diffuse interstellar dust in our Galaxy. The mission is optimized for large angular scales, with coarse angular resolution (around 1.5 degrees FWHM), and wide sky coverage (25% of the sky). The payload will fly in a circumpolar long duration balloon mission during the polar night. Using the Earth as a giant solar shield, the instrument will spin in azimuth, observing a large fraction of the northern sky. The payload will host two instruments. An array of coherent polarimeters using cryogenic HEMT amplifiers will survey the sky at 43 and 90 GHz. An array of bolometric polarimeters, using large throughput multi-mode bolometers and rotating Half Wave Plates (HWP), will survey the same sky region in three bands at 95, 145 and 245 GHz. The wide frequency coverage will allow optimal control of the polarized foregrounds, with comparable angular resolution at all frequencies.
△ Less
Submitted 1 August, 2012;
originally announced August 2012.