In-flight gain monitoring of SPIDER's transition-edge sensor arrays
Authors:
J. P. Filippini,
A. E. Gambrel,
A. S. Rahlin,
E. Y. Young,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
A. A. Fraisse,
K. Freese,
M. Galloway,
N. N. Gandilo,
K. Ganga,
R. Gualtieri
, et al. (45 additional authors not shown)
Abstract:
Experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES's small-signal power response from its electrical respons…
▽ More
Experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES's small-signal power response from its electrical response that is exact in the limit of strong electrothermal feedback. We discuss the application and validation of this method using flight data from SPIDER, a balloon-borne telescope that observes the polarization of the cosmic microwave background with more than 2000 TESs. This method may prove useful for future balloon- and space-based instruments, where observing time and ground control bandwidth are limited.
△ Less
Submitted 16 June, 2022; v1 submitted 1 December, 2021;
originally announced December 2021.
-
A Simulation-Based Method for Correcting Mode Coupling in CMB Angular Power Spectra
Authors:
J. S. -Y. Leung,
J. Hartley,
J. M. Nagy,
C. B. Netterfield,
J. A. Shariff,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Doré,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (45 additional authors not shown)
Abstract:
Modern CMB analysis pipelines regularly employ complex time-domain filters, beam models, masking, and other techniques during the production of sky maps and their corresponding angular power spectra. However, these processes can generate couplings between multipoles from the same spectrum and from different spectra, in addition to the typical power attenuation. Within the context of pseudo-…
▽ More
Modern CMB analysis pipelines regularly employ complex time-domain filters, beam models, masking, and other techniques during the production of sky maps and their corresponding angular power spectra. However, these processes can generate couplings between multipoles from the same spectrum and from different spectra, in addition to the typical power attenuation. Within the context of pseudo-$C_\ell$ based, MASTER-style analyses, the net effect of the time-domain filtering is commonly approximated by a multiplicative transfer function, $F_{\ell}$, that can fail to capture mode mixing and is dependent on the spectrum of the signal. To address these shortcomings, we have developed a simulation-based spectral correction approach that constructs a two-dimensional transfer matrix, $J_{\ell\ell'}$, which contains information about mode mixing in addition to mode attenuation. We demonstrate the application of this approach on data from the first flight of the SPIDER balloon-borne CMB experiment.
△ Less
Submitted 21 April, 2022; v1 submitted 1 November, 2021;
originally announced November 2021.
-
The XFaster Power Spectrum and Likelihood Estimator for the Analysis of Cosmic Microwave Background Maps
Authors:
A. E. Gambrel,
A. S. Rahlin,
X. Song,
C. R. Contaldi,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
A. A. Fraisse,
K. Freese,
M. Galloway,
N. N. Gandilo,
R. Gualtieri,
J. E. Gudmundsson,
M. Halpern
, et al. (42 additional authors not shown)
Abstract:
We present the XFaster analysis package. XFaster is a fast, iterative angular power spectrum estimator based on a diagonal approximation to the quadratic Fisher matrix estimator. XFaster uses Monte Carlo simulations to compute noise biases and filter transfer functions and is thus a hybrid of both Monte Carlo and quadratic estimator methods. In contrast to conventional pseudo-$C_\ell$ based method…
▽ More
We present the XFaster analysis package. XFaster is a fast, iterative angular power spectrum estimator based on a diagonal approximation to the quadratic Fisher matrix estimator. XFaster uses Monte Carlo simulations to compute noise biases and filter transfer functions and is thus a hybrid of both Monte Carlo and quadratic estimator methods. In contrast to conventional pseudo-$C_\ell$ based methods, the algorithm described here requires a minimal number of simulations, and does not require them to be precisely representative of the data to estimate accurate covariance matrices for the bandpowers. The formalism works with polarization-sensitive observations and also data sets with identical, partially overlapping, or independent survey regions. The method was first implemented for the analysis of BOOMERanG data, and also used as part of the Planck analysis. Here, we describe the full, publicly available analysis package, written in Python, as developed for the analysis of data from the 2015 flight of the SPIDER instrument. The package includes extensions for self-consistently estimating null spectra and for estimating fits for Galactic foreground contributions. We show results from the extensive validation of XFaster using simulations, and its application to the SPIDER data set.
△ Less
Submitted 24 May, 2021; v1 submitted 2 April, 2021;
originally announced April 2021.
-
A Constraint on Primordial $B$-Modes from the First Flight of the SPIDER Balloon-Borne Telescope
Authors:
SPIDER Collaboration,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Doré,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel,
N. N. Gandilo,
K. Ganga,
R. Gualtieri,
J. E. Gudmundsson
, et al. (46 additional authors not shown)
Abstract:
We present the first linear polarization measurements from the 2015 long-duration balloon flight of SPIDER, an experiment designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. Results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency test…
▽ More
We present the first linear polarization measurements from the 2015 long-duration balloon flight of SPIDER, an experiment designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. Results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency tests on these data. While the polarized CMB anisotropy from primordial density perturbations is the dominant signal in this region of sky, Galactic dust emission is also detected with high significance; Galactic synchrotron emission is found to be negligible in the SPIDER bands. We employ two independent foreground-removal techniques in order to explore the sensitivity of the cosmological result to the assumptions made by each. The primary method uses a dust template derived from Planck data to subtract the Galactic dust signal. A second approach, employing a joint analysis of SPIDER and Planck data in the harmonic domain, assumes a modified-blackbody model for the spectral energy distribution of the dust with no constraint on its spatial morphology. Using a likelihood that jointly samples the template amplitude and $r$ parameter space, we derive 95% upper limits on the primordial tensor-to-scalar ratio from Feldman-Cousins and Bayesian constructions, finding $r<0.11$ and $r<0.19$, respectively. Roughly half the uncertainty in $r$ derives from noise associated with the template subtraction. New data at 280 GHz from SPIDER's second flight will complement the Planck polarization maps, providing powerful measurements of the polarized Galactic dust emission.
△ Less
Submitted 24 March, 2021;
originally announced March 2021.
-
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Authors:
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
D. Barkats,
S. J. Benton,
C. A. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
I. Buder,
E. Bullock,
G. Chattopadhyay,
G. Davis,
P. K. Day,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
S. R. Hildebrandt,
G. C. Hilton,
V. Hristov,
H. Hui
, et al. (42 additional authors not shown)
Abstract:
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays…
▽ More
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at 95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ~0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the SPIDER instrument, and development of this technology is ongoing.
△ Less
Submitted 2 February, 2015;
originally announced February 2015.
-
Antenna-coupled TES bolometers for the Keck Array, Spider, and Polar-1
Authors:
R. O'Brient,
P. A. R. Ade,
Z. Ahmed,
R. W. Aikin,
M. Amiri,
S. Benton,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
G. Davis,
P. Day,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
J. Grayson,
M. Halpern,
M. Hasselfield,
G. Hilton,
V. V. Hristov,
H. Hui,
K. Irwin
, et al. (28 additional authors not shown)
Abstract:
Between the BICEP2 and Keck Array experiments, we have deployed over 1500 dual polarized antenna coupled bolometers to map the Cosmic Microwave Background's polarization. We have been able to rapidly deploy these detectors because they are completely planar with an integrated phased-array antenna. Through our experience in these experiments, we have learned of several challenges with this technolo…
▽ More
Between the BICEP2 and Keck Array experiments, we have deployed over 1500 dual polarized antenna coupled bolometers to map the Cosmic Microwave Background's polarization. We have been able to rapidly deploy these detectors because they are completely planar with an integrated phased-array antenna. Through our experience in these experiments, we have learned of several challenges with this technology- specifically the beam synthesis in the antenna- and in this paper we report on how we have modified our designs to mitigate these challenges. In particular, we discus differential steering errors between the polarization pairs' beam centroids due to microstrip cross talk and gradients of penetration depth in the niobium thin films of our millimeter wave circuits. We also discuss how we have suppressed side lobe response with a Gaussian taper of our antenna illumination pattern. These improvements will be used in Spider, Polar-1, and this season's retrofit of Keck Array.
△ Less
Submitted 6 August, 2012;
originally announced August 2012.
-
Optimization and sensitivity of the Keck Array
Authors:
S. Kernasovskiy,
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
S. Benton,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
G. Davis,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
G. Hiltion,
V. V. Hristov,
K. Irwin,
J. M. Kovac,
C. L. Kuo,
E. Leitch,
M. Lueker
, et al. (19 additional authors not shown)
Abstract:
The Keck Array (SPUD) began observing the cosmic microwave background's polarization in the winter of 2011 at the South Pole. The Keck Array follows the success of the predecessor experiments Bicep and Bicep2, using five on-axis refracting telescopes. These have a combined imaging array of 2500 antenna-coupled TES bolometers read with a SQUID-based time domain multiplexing system. We will discuss…
▽ More
The Keck Array (SPUD) began observing the cosmic microwave background's polarization in the winter of 2011 at the South Pole. The Keck Array follows the success of the predecessor experiments Bicep and Bicep2, using five on-axis refracting telescopes. These have a combined imaging array of 2500 antenna-coupled TES bolometers read with a SQUID-based time domain multiplexing system. We will discuss the detector noise and the optimization of the readout. The achieved sensitivity of the Keck Array is 11.5 μK_(CMB)*sqrt{s} in the 2012 configuration.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.
-
Optical Characterization of the Keck Array Polarimeter at the South Pole
Authors:
A. G. Vieregg,
P. A. R. Ade,
R. Aikin,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
K. J. Bradford,
J. A. Brevik,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. S. Gordon,
M. Halpern,
G. Hilton,
V. V. Hristov,
K. Irwin,
S. Kernasovskiy,
J. M. Kovac,
C. L. Kuo,
E. Leitch,
M. Lueker,
T. Montroy,
C. B. Netterfield
, et al. (15 additional authors not shown)
Abstract:
The Keck Array (SPUD) is a set of microwave polarimeters that observes from the South Pole at degree angular scales in search of a signature of Inflation imprinted as B-mode polarization in the Cosmic Microwave Background (CMB). The first three Keck Array receivers were deployed during the 2010-2011 Austral summer, followed by two new receivers in the 2011-2012 summer season, completing the full f…
▽ More
The Keck Array (SPUD) is a set of microwave polarimeters that observes from the South Pole at degree angular scales in search of a signature of Inflation imprinted as B-mode polarization in the Cosmic Microwave Background (CMB). The first three Keck Array receivers were deployed during the 2010-2011 Austral summer, followed by two new receivers in the 2011-2012 summer season, completing the full five-receiver array. All five receivers are currently observing at 150 GHz. The Keck Array employs the field-proven BICEP/BICEP2 strategy of using small, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. We describe our efforts to characterize the main beam shape and beam shape mismatch between co-located orthogonally-polarized detector pairs, and discuss the implications of measured differential beam parameters on temperature to polarization leakage in CMB analysis.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.
-
BICEP2 and Keck Array operational overview and status of observations
Authors:
R. W. Ogburn IV,
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
S. J. Benton,
C. A. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
E. Bullock,
B. Burger,
G. Davis,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Gordon,
M. Halpern,
M. Hasselfield,
G. Hilton,
V. V. Hristov,
H. Hui,
K. Irwin,
J. P. Kaufman
, et al. (28 additional authors not shown)
Abstract:
The BICEP2 and Keck Array experiments are designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 2-4 degrees (l=50-100). This is the region in which the B-mode signal, a signature prediction of cosmic inflation, is expected to peak. BICEP2 was deployed to the South Pole at the end of 2009 and is in the middle of its third year of observing with 500 polar…
▽ More
The BICEP2 and Keck Array experiments are designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 2-4 degrees (l=50-100). This is the region in which the B-mode signal, a signature prediction of cosmic inflation, is expected to peak. BICEP2 was deployed to the South Pole at the end of 2009 and is in the middle of its third year of observing with 500 polarization-sensitive detectors at 150 GHz. The Keck Array was deployed to the South Pole at the end of 2010, initially with three receivers--each similar to BICEP2. An additional two receivers have been added during the 2011-12 summer. We give an overview of the two experiments, report on substantial gains in the sensitivity of the two experiments after post-deployment optimization, and show preliminary maps of CMB polarization from BICEP2.
△ Less
Submitted 2 August, 2012;
originally announced August 2012.
-
SPIDER: Probing the Early Universe with a Suborbital Polarimeter
Authors:
A. A. Fraisse,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. Bryan,
B. Burger,
H. C. Chiang,
C. N. Clark,
C. R. Contaldi,
B. P. Crill,
G. Davis,
O. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (21 additional authors not shown)
Abstract:
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a divergence-free polarization pattern ("B-modes") in the Cosmic Microwave Background (CMB). In the inflationary scenario, the amplitude of this signal is proportional to that of the primordial scalar perturbations through the tensor-to-scalar ratio r. We show that the expected level of systematic error in the SPIDER instrum…
▽ More
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a divergence-free polarization pattern ("B-modes") in the Cosmic Microwave Background (CMB). In the inflationary scenario, the amplitude of this signal is proportional to that of the primordial scalar perturbations through the tensor-to-scalar ratio r. We show that the expected level of systematic error in the SPIDER instrument is significantly below the amplitude of an interesting cosmological signal with r=0.03. We present a scanning strategy that enables us to minimize uncertainty in the reconstruction of the Stokes parameters used to characterize the CMB, while accessing a relatively wide range of angular scales. Evaluating the amplitude of the polarized Galactic emission in the SPIDER field, we conclude that the polarized emission from interstellar dust is as bright or brighter than the cosmological signal at all SPIDER frequencies (90 GHz, 150 GHz, and 280 GHz), a situation similar to that found in the "Southern Hole." We show that two ~20-day flights of the SPIDER instrument can constrain the amplitude of the B-mode signal to r<0.03 (99% CL) even when foreground contamination is taken into account. In the absence of foregrounds, the same limit can be reached after one 20-day flight.
△ Less
Submitted 2 May, 2013; v1 submitted 15 June, 2011;
originally announced June 2011.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.
-
Design and performance of the Spider instrument
Authors:
M. C. Runyan,
P. A. R. Ade,
M. Amiri,
S. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Dore,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. Fissel,
N. Gandilo,
S. R. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
M. Halpern,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (18 additional authors not shown)
Abstract:
Here we describe the design and performance of the Spider instrument. Spider is a balloon-borne cosmic microwave background polarization imager that will map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high sensitivity. This paper discusses the general design principles of the instrument inserts, mechanical structures, optics, focal plane architecture, thermal architectu…
▽ More
Here we describe the design and performance of the Spider instrument. Spider is a balloon-borne cosmic microwave background polarization imager that will map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high sensitivity. This paper discusses the general design principles of the instrument inserts, mechanical structures, optics, focal plane architecture, thermal architecture, and magnetic shielding of the TES sensors and SQUID multiplexer. We also describe the optical, noise, and magnetic shielding performance of the 145 GHz prototype instrument insert.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.
-
SPIDER: a balloon-borne CMB polarimeter for large angular scales
Authors:
J. P. Filippini,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
B. Burger,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
M. Farhang,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (19 additional authors not shown)
Abstract:
We describe SPIDER, a balloon-borne instrument to map the polarization of the millimeter-wave sky with degree angular resolution. Spider consists of six monochromatic refracting telescopes, each illuminating a focal plane of large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting transition-edge sensors are distributed among three observing bands centered at 90, 150, and 28…
▽ More
We describe SPIDER, a balloon-borne instrument to map the polarization of the millimeter-wave sky with degree angular resolution. Spider consists of six monochromatic refracting telescopes, each illuminating a focal plane of large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting transition-edge sensors are distributed among three observing bands centered at 90, 150, and 280 GHz. A cold half-wave plate at the aperture of each telescope modulates the polarization of incoming light to control systematics. Spider's first flight will be a 20-30-day Antarctic balloon campaign in December 2011. This flight will map \sim8% of the sky to achieve unprecedented sensitivity to the polarization signature of the gravitational wave background predicted by inflationary cosmology. The Spider mission will also serve as a proving ground for these detector technologies in preparation for a future satellite mission.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.
-
The Keck Array: a pulse tube cooled CMB polarimeter
Authors:
C. D. Sheehy,
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
S. Benton,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
G. Hilton,
V. V. Hristov,
K. Irwin,
J. P. Kaufman,
B. G. Keating,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
E. M. Leitch
, et al. (19 additional authors not shown)
Abstract:
The Keck Array is a cosmic microwave background (CMB) polarimeter that will begin observing from the South Pole in late 2010. The initial deployment will consist of three telescopes similar to BICEP2 housed in ultra-compact, pulse tube cooled cryostats. Two more receivers will be added the following year. In these proceedings we report on the design and performance of the Keck cryostat. We also re…
▽ More
The Keck Array is a cosmic microwave background (CMB) polarimeter that will begin observing from the South Pole in late 2010. The initial deployment will consist of three telescopes similar to BICEP2 housed in ultra-compact, pulse tube cooled cryostats. Two more receivers will be added the following year. In these proceedings we report on the design and performance of the Keck cryostat. We also report some initial results on the performance of antenna-coupled TES detectors operating in the presence of a pulse tube. We find that the performance of the detectors is not seriously impacted by the replacement of BICEP2's liquid helium cryostat with a pulse tube cooled cryostat.
△ Less
Submitted 28 April, 2011;
originally announced April 2011.
-
Spider Optimization II: Optical, Magnetic and Foreground Effects
Authors:
D. T. O'Dea,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. Bryan,
B. Burger,
H. C. Chiang,
C. N. Clark,
C. R. Contaldi,
B. P. Crill,
G. Davis,
O. Dore,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
G. Hilton,
W. Holmes
, et al. (21 additional authors not shown)
Abstract:
Spider is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. Spider's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental s…
▽ More
Spider is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. Spider's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental systematic errors must be controlled with unprecedented accuracy. Here, we build on previous work to use simulations of Spider observations to examine the impact of several systematic effects that have been characterized through testing and modeling of various instrument components. In particular, we investigate the impact of the non-ideal spectral response of the half-wave plates, coupling between focal plane components and the Earth's magnetic field, and beam mismatches and asymmetries. We also present a model of diffuse polarized foreground emission based on a three-dimensional model of the Galactic magnetic field and dust, and study the interaction of this foreground emission with our observation strategy and instrumental effects. We find that the expected level of foreground and systematic contamination is sufficiently low for Spider to achieve its science goals.
△ Less
Submitted 2 February, 2011;
originally announced February 2011.
-
Antenna-coupled TES Bolometer Arrays for BICEP2/Keck and SPIDER
Authors:
A. Orlando,
R. W Aikin,
M. Amiri,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
G. Chattopadthyay,
P. K. Day,
J. P. Filippini,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
K. D. Irwin,
M. Kenyon,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
H. G. LeDuc,
N. Llombart,
H. T. Nguyen,
R. W. Ogburn,
C. D. Reintsema,
M. C. Runyan
, et al. (6 additional authors not shown)
Abstract:
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters targeting the B-mode polarization induced by primordial gravitational waves from inflation. They will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220 GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays are assembled t…
▽ More
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters targeting the B-mode polarization induced by primordial gravitational waves from inflation. They will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220 GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays are assembled together to make a focal plane, for a total of 256 dual-polarization elements (512 TES sensors). The detector arrays are integrated with a time-domain SQUID multiplexer developed at NIST and read out using the multi-channels electronics (MCE) developed at the University of British Columbia. Following our progress in improving detector parameters uniformity across the arrays and fabrication yield, our main effort has focused on improving detector arrays optical and noise performances, in order to produce science grade focal planes achieving target sensitivities. We report on changes in detector design implemented to optimize such performances and following focal plane arrays characterization. BICEP2 has deployed a first 150 GHz science grade focal plane to the South Pole in December 2009.
△ Less
Submitted 19 September, 2010;
originally announced September 2010.
-
Modeling and characterization of the SPIDER half-wave plate
Authors:
Sean A. Bryan,
Peter A. R. Ade,
Mandana Amiri,
Steve Benton,
Richard Bihary,
James J. Bock,
J. Richard Bond,
Joseph A. Bonetti,
H. Cynthia Chiang,
Carlo R. Contaldi,
Brendan P. Crill,
Daniel O'Dea,
Olivier Dore,
Marzieh Farhang,
Jeffrey P. Filippini,
Laura Fissel,
Natalie Gandilo,
Sunil Golwala,
Jon E. Gudmundsson,
Matthew Hasselfield,
Mark Halpern,
Kyle R. Helson,
Gene Hilton,
Warren Holmes,
Viktor V. Hristov
, et al. (20 additional authors not shown)
Abstract:
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave t…
▽ More
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave transmission spectra of the sapphire at room and cryogenic temperatures. The spectra are consistent with our physical optics model, and the data gives excellent measurements of the indices of A-cut sapphire. We have also taken preliminary spectra of the integrated HWP, optical system, and detectors in the prototype Spider receiver. We calculate the variation in response of the HWP between observing the CMB and foreground spectra, and estimate that it should not limit the Spider constraints on inflation.
△ Less
Submitted 19 June, 2010;
originally announced June 2010.
-
Antenna-coupled TES bolometer arrays for CMB polarimetry
Authors:
C. L. Kuo,
J. J. Bock,
J. A. Bonetti,
J. Brevik,
G. Chattopadhyay,
P. K. Day,
S. Golwala,
M. Kenyon,
A. E. Lange,
H. G. LeDuc,
H. Nguyen,
R. W. Ogburn,
A. Orlando,
A. Trangsrud,
A. Turner,
G. Wang,
J. Zmuidzinas
Abstract:
We describe the design and performance of polarization selective antenna-coupled TES arrays that will be used in several upcoming Cosmic Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully lithographic polarimeter arrays utilize planar phased-antennas for collimation (F/4 beam) and microstrip filters for band definition (25% bandwidth). These devices demonstrate high optical…
▽ More
We describe the design and performance of polarization selective antenna-coupled TES arrays that will be used in several upcoming Cosmic Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully lithographic polarimeter arrays utilize planar phased-antennas for collimation (F/4 beam) and microstrip filters for band definition (25% bandwidth). These devices demonstrate high optical efficiency, excellent beam shapes, and well-defined spectral bands. The dual-polarization antennas provide well-matched beams and low cross polarization response, both important for high-fidelity polarization measurements. These devices have so far been developed for the 100 GHz and 150 GHz bands, two premier millimeter-wave atmospheric windows for CMB observations. In the near future, the flexible microstrip-coupled architecture can provide photon noise-limited detection for the entire frequency range of the CMBPOL mission. This paper is a summary of the progress we have made since the 2006 SPIE meeting in Orlando, FL.
△ Less
Submitted 11 August, 2009;
originally announced August 2009.
-
Spatially Selective and Reversible Doping Control in Cuprate Films
Authors:
Seongshik Oh,
Joseph A. Bonetti,
Kevin Inderhees,
D. J. Van Harlingen,
J. N. Eckstein
Abstract:
We describe a reversible, spatially-controlled doping method for cuprate films. The technique has been used to create superconductor-antiferromagnetic insulator-superconductor (S-AFI-S) junctions and optimally doped superconductor-underdoped superconductor-optimally doped superconductor (OS-US-OS) cuprate structures. We demonstrate how the S-AFI-S structure can be employed to reliably measure th…
▽ More
We describe a reversible, spatially-controlled doping method for cuprate films. The technique has been used to create superconductor-antiferromagnetic insulator-superconductor (S-AFI-S) junctions and optimally doped superconductor-underdoped superconductor-optimally doped superconductor (OS-US-OS) cuprate structures. We demonstrate how the S-AFI-S structure can be employed to reliably measure the transport properties of the antiferromagnetic insulator region at cryogenic temperatures using the superconductors as seamless electrical leads. We also discuss applied and fundamental issues which may be addressed with the structures created with this doping method. Although it is implemented on a cuprate film (YBa2Cu3O7-delta) in this work, the method can also be applied to any mixed-valence transition metal oxide whose physical properties are determined by oxygen content.
△ Less
Submitted 10 August, 2005;
originally announced August 2005.
-
Electronic Transport in Underdoped YBCO Nanowires: Possible Observation of Stripe Domains
Authors:
J. A. Bonetti,
D. S. Caplan,
D. J. Van Harlingen,
M. B. Weissman
Abstract:
We have measured the transport properties of a series of underdoped YBa2Cu3O7 nanowires fabricated with widths of 100-250 nm. We observe large telegraph-like fluctuations in the resistance between the pseudogap temperature T* and the superconducting transition temperature Tc, consistent with the formation and dynamics of a domain structure such as that created by charge stripes. We also find ano…
▽ More
We have measured the transport properties of a series of underdoped YBa2Cu3O7 nanowires fabricated with widths of 100-250 nm. We observe large telegraph-like fluctuations in the resistance between the pseudogap temperature T* and the superconducting transition temperature Tc, consistent with the formation and dynamics of a domain structure such as that created by charge stripes. We also find anomalous hysteretic steps in the current-voltage characteristics well below Tc.
△ Less
Submitted 9 March, 2004;
originally announced March 2004.