-
Low-frequency pulse-jitter measurement with the uGMRT I : PSR J0437$-$4715
Authors:
Tomonosuke Kikunaga,
Shinnosuke Hisano,
Neelam Dhanda Batra,
Shantanu Desai,
Bhal Chandra Joshi,
Manjari Bagchi,
T. Prabu,
Keitaro Takahashi,
Swetha Arumugam,
Adarsh Bathula,
Subhajit Dandapat,
Debabrata Deb,
Churchil Dwivedi,
Yashwant Gupta,
Shebin Jose Jacob,
Fazal Kareem,
Nobleson K,
Pragna Mamidipaka,
Avinash Kumar Paladi,
Arul Pandian B,
Prerna Rana,
Jaikhomba Singha,
Aman Srivastava,
Mayuresh Surnis,
Pratik Tarafdar
Abstract:
High-precision pulsar timing observations are limited in their accuracy by the jitter noise that appears in the arrival time of pulses. Therefore, it is important to systematically characterise the amplitude of the jitter noise and its variation with frequency. In this paper, we provide jitter measurements from low-frequency wideband observations of PSR J0437$-$4715 using data obtained as part of…
▽ More
High-precision pulsar timing observations are limited in their accuracy by the jitter noise that appears in the arrival time of pulses. Therefore, it is important to systematically characterise the amplitude of the jitter noise and its variation with frequency. In this paper, we provide jitter measurements from low-frequency wideband observations of PSR J0437$-$4715 using data obtained as part of the Indian Pulsar Timing Array experiment. We were able to detect jitter in both the 300 - 500 MHz and 1260 - 1460 MHz observations of the upgraded Giant Metrewave Radio Telescope (uGMRT). The former is the first jitter measurement for this pulsar below 700 MHz, and the latter is in good agreement with results from previous studies. In addition, at 300 - 500 MHz, we investigated the frequency dependence of the jitter by calculating the jitter for each sub-banded arrival time of pulses. We found that the jitter amplitude increases with frequency. This trend is opposite as compared to previous studies, indicating that there is a turnover at intermediate frequencies. It will be possible to investigate this in more detail with uGMRT observations at 550 - 750 MHz and future high sensitive wideband observations from next generation telescopes, such as the Square Kilometre Array. We also explored the effect of jitter on the high precision dispersion measure (DM) measurements derived from short duration observations. We find that even though the DM precision will be better at lower frequencies due to the smaller amplitude of jitter noise, it will limit the DM precision for high signal-to-noise observations, which are of short durations. This limitation can be overcome by integrating for a long enough duration optimised for a given pulsar.
△ Less
Submitted 18 April, 2024; v1 submitted 4 December, 2023;
originally announced December 2023.
-
Using low-frequency scatter-broadening measurements for precision estimates of dispersion measures
Authors:
Jaikhomba Singha,
Bhal Chandra Joshi,
M. A. Krishnakumar,
Fazal Kareem,
Adarsh Bathula,
Churchil Dwivedi,
Shebin Jose Jacob,
Shantanu Desai,
Pratik Tarafdar,
P. Arumugam,
Swetha Arumugam,
Manjari Bagchi,
Neelam Dhanda Batra,
Subhajit Dandapat,
Debabrata Deb,
Jyotijwal Debnath,
A Gopakumar,
Yashwant Gupta,
Shinnosuke Hisano,
Ryo Kato,
Tomonosuke Kikunaga,
Piyush Marmat,
K. Nobleson,
Avinash K. Paladi,
Arul Pandian B.
, et al. (6 additional authors not shown)
Abstract:
A pulsar's pulse profile gets broadened at low frequencies due to dispersion along the line of sight or due to multi-path propagation. The dynamic nature of the interstellar medium makes both of these effects time-dependent and introduces slowly varying time delays in the measured times-of-arrival similar to those introduced by passing gravitational waves. In this article, we present a new method…
▽ More
A pulsar's pulse profile gets broadened at low frequencies due to dispersion along the line of sight or due to multi-path propagation. The dynamic nature of the interstellar medium makes both of these effects time-dependent and introduces slowly varying time delays in the measured times-of-arrival similar to those introduced by passing gravitational waves. In this article, we present a new method to correct for such delays by obtaining unbiased dispersion measure (DM) measurements by using low-frequency estimates of the scattering parameters. We evaluate this method by comparing the obtained DM estimates with those, where scatter-broadening is ignored using simulated data. A bias is seen in the estimated DMs for simulated data with pulse-broadening with a larger variability for a data set with a variable frequency scaling index, $α$, as compared to that assuming a Kolmogorov turbulence. Application of the proposed method removes this bias robustly for data with band averaged signal-to-noise ratio larger than 100. We report, for the first time, the measurements of the scatter-broadening time and $α$ from analysis of PSR J1643$-$1224, observed with upgraded Giant Metrewave Radio Telescope as part of the Indian Pulsar Timing Array experiment. These scattering parameters were found to vary with epoch and $α$ was different from that expected for Kolmogorov turbulence. Finally, we present the DM time-series after application of the new technique to PSR J1643$-$1224.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.
-
Multi-band Extension of the Wideband Timing Technique
Authors:
Avinash Kumar Paladi,
Churchil Dwivedi,
Prerna Rana,
Nobleson K,
Abhimanyu Susobhanan,
Bhal Chandra Joshi,
Pratik Tarafdar,
Debabrata Deb,
Swetha Arumugam,
A Gopakumar,
M A Krishnakumar,
Neelam Dhanda Batra,
Jyotijwal Debnath,
Fazal Kareem,
Paramasivan Arumugam,
Manjari Bagchi,
Adarsh Bathula,
Subhajit Dandapat,
Shantanu Desai,
Yashwant Gupta,
Shinnosuke Hisano,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Neel Kolhe,
Yogesh Maan
, et al. (5 additional authors not shown)
Abstract:
The wideband timing technique enables the high-precision simultaneous estimation of pulsar Times of Arrival (ToAs) and Dispersion Measures (DMs) while effectively modeling frequency-dependent profile evolution. We present two novel independent methods that extend the standard wideband technique to handle simultaneous multi-band pulsar data incorporating profile evolution over a larger frequency sp…
▽ More
The wideband timing technique enables the high-precision simultaneous estimation of pulsar Times of Arrival (ToAs) and Dispersion Measures (DMs) while effectively modeling frequency-dependent profile evolution. We present two novel independent methods that extend the standard wideband technique to handle simultaneous multi-band pulsar data incorporating profile evolution over a larger frequency span to estimate DMs and ToAs with enhanced precision. We implement the wideband likelihood using the libstempo python interface to perform wideband timing in the tempo2 framework. We present the application of these techniques to the dataset of fourteen millisecond pulsars observed simultaneously in Band 3 (300 - 500 MHz) and Band 5 (1260 - 1460 MHz) of the upgraded Giant Metrewave Radio Telescope (uGMRT) with a large band gap of 760 MHz as a part of the Indian Pulsar Timing Array (InPTA) campaign. We achieve increased ToA and DM precision and sub-microsecond root mean square post-fit timing residuals by combining simultaneous multi-band pulsar observations done in non-contiguous bands for the first time using our novel techniques.
△ Less
Submitted 8 November, 2023; v1 submitted 25 April, 2023;
originally announced April 2023.
-
Nanohertz Gravitational Wave Astronomy during the SKA Era: An InPTA perspective
Authors:
Bhal Chandra Joshi,
Achamveedu Gopakumar,
Arul Pandian,
Thiagaraj Prabu,
Lankeswar Dey,
Manjari Bagchi,
Shantanu Desai,
Pratik Tarafdar,
Prerna Rana,
Yogesh Maan,
Neelam Dhanda Batra,
Raghav Girgaonkar,
Nikita Agarwal,
Paramasivan Arumugam,
Sarmistha Banik,
Avishek Basu,
Adarsh Bathula,
Subhajit Dandapat,
Yashwant Gupta,
Shinnosuke Hisano,
Ryo Kato,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Neel Kolhe,
M. A. Krishnakumar
, et al. (12 additional authors not shown)
Abstract:
Decades long monitoring of millisecond pulsars, which exhibit highly stable rotational periods, in pulsar timing array experiments is on the threshold of discovering nanohertz stochastic gravitational wave background. This paper describes the Indian Pulsar timing array (InPTA) experiment, which employs the upgraded Giant Metrewave Radio Telescope (uGMRT) for timing an ensemble of millisecond pulsa…
▽ More
Decades long monitoring of millisecond pulsars, which exhibit highly stable rotational periods, in pulsar timing array experiments is on the threshold of discovering nanohertz stochastic gravitational wave background. This paper describes the Indian Pulsar timing array (InPTA) experiment, which employs the upgraded Giant Metrewave Radio Telescope (uGMRT) for timing an ensemble of millisecond pulsars for this purpose. We highlight InPTA's observation strategies and analysis methods, which are relevant for a future PTA experiment with the more sensitive Square Kilometer Array (SKA) telescope. We show that the unique multi-sub-array multi-band wide-bandwidth frequency coverage of the InPTA provides Dispersion Measure estimates with unprecedented precision for PTA pulsars, e.g., ~ 2 x 10{-5} pc-cm{-3} for PSR J1909-3744. Configuring the SKA-low and SKA-mid as two and four sub-arrays respectively, it is shown that comparable precision is achievable, using observation strategies similar to those pursued by the InPTA, for a larger sample of 62 pulsars requiring about 26 and 7 hours per epoch for the SKA-mid and the SKA-low telescopes respectively. We also review the ongoing efforts to develop PTA-relevant general relativistic constructs that will be required to search for nanohertz gravitational waves from isolated super-massive black hole binary systems like blazar OJ 287. These efforts should be relevant to pursue persistent multi-messenger gravitational wave astronomy during the forthcoming era of the SKA telescope, the Thirty Meter Telescope, and the next-generation Event Horizon Telescope.
△ Less
Submitted 13 July, 2022;
originally announced July 2022.
-
The Indian Pulsar Timing Array: First data release
Authors:
Pratik Tarafdar,
Nobleson K.,
Prerna Rana,
Jaikhomba Singha,
M. A. Krishnakumar,
Bhal Chandra Joshi,
Avinash Kumar Paladi,
Neel Kolhe,
Neelam Dhanda Batra,
Nikita Agarwal,
Adarsh Bathula,
Subhajit Dandapat,
Shantanu Desai,
Lankeswar Dey,
Shinnosuke Hisano,
Prathamesh Ingale,
Ryo Kato,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Piyush Marmat,
B. Arul Pandian,
T. Prabu,
Aman Srivastava,
Mayuresh Surnis,
Sai Chaitanya Susarla
, et al. (13 additional authors not shown)
Abstract:
We present the pulse arrival times and high-precision dispersion measure estimates for 14 millisecond pulsars observed simultaneously in the 300-500 MHz and 1260-1460 MHz frequency bands using the upgraded Giant Metrewave Radio Telescope (uGMRT). The data spans over a baseline of 3.5 years (2018-2021), and is the first official data release made available by the Indian Pulsar Timing Array collabor…
▽ More
We present the pulse arrival times and high-precision dispersion measure estimates for 14 millisecond pulsars observed simultaneously in the 300-500 MHz and 1260-1460 MHz frequency bands using the upgraded Giant Metrewave Radio Telescope (uGMRT). The data spans over a baseline of 3.5 years (2018-2021), and is the first official data release made available by the Indian Pulsar Timing Array collaboration. This data release presents a unique opportunity for investigating the interstellar medium effects at low radio frequencies and their impact on the timing precision of pulsar timing array experiments. In addition to the dispersion measure time series and pulse arrival times obtained using both narrowband and wideband timing techniques, we also present the dispersion measure structure function analysis for selected pulsars. Our ongoing investigations regarding the frequency dependence of dispersion measures have been discussed. Based on the preliminary analysis for five millisecond pulsars, we do not find any conclusive evidence of chromaticity in dispersion measures. Data from regular simultaneous two-frequency observations are presented for the first time in this work. This distinctive feature leads us to the highest precision dispersion measure estimates obtained so far for a subset of our sample. Simultaneous multi-band uGMRT observations in Band 3 and Band 5 are crucial for high-precision dispersion measure estimation and for the prospect of expanding the overall frequency coverage upon the combination of data from the various Pulsar Timing Array consortia in the near future. Parts of the data presented in this work are expected to be incorporated into the upcoming third data release of the International Pulsar Timing Array.
△ Less
Submitted 25 October, 2022; v1 submitted 18 June, 2022;
originally announced June 2022.
-
Low-frequency wideband timing of InPTA pulsars observed with the uGMRT
Authors:
K Nobleson,
Nikita Agarwal,
Raghav Girgaonkar,
Arul Pandian,
Bhal Chandra Joshi,
M A Krishnakumar,
Abhimanyu Susobhanan,
Shantanu Desai,
T Prabu,
Adarsh Bathula,
Timothy T Pennucci,
Sarmistha Banik,
Manjari Bagchi,
Neelam Dhanda Batra,
Arpita Choudhary,
Subhajit Dandapat,
Lankeswar Dey,
Yashwant Gupta,
Shinnosuke Hisano,
Ryo Kato,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Neel Kolhe,
Yogesh Maan,
Piyush Marmat
, et al. (7 additional authors not shown)
Abstract:
High-precision measurements of the pulsar dispersion measure (DM) are possible using telescopes with low-frequency wideband receivers. We present an initial study of the application of the wideband timing technique, which can simultaneously measure the pulsar times of arrival (ToAs) and DMs, for a set of five pulsars observed with the upgraded Giant Metrewave Radio Telescope (uGMRT) as part of the…
▽ More
High-precision measurements of the pulsar dispersion measure (DM) are possible using telescopes with low-frequency wideband receivers. We present an initial study of the application of the wideband timing technique, which can simultaneously measure the pulsar times of arrival (ToAs) and DMs, for a set of five pulsars observed with the upgraded Giant Metrewave Radio Telescope (uGMRT) as part of the Indian Pulsar Timing Array (InPTA) campaign. We have used the observations with the 300-500 MHz band of the uGMRT for this purpose. We obtain high precision in DM measurements with precisions of the order 10^{-6}cm^{-3}pc. The ToAs obtained have sub-μs precision and the root-mean-square of the post-fit ToA residuals are in the sub-μs range. We find that the uncertainties in the DMs and ToAs obtained with this wideband technique, applied to low-frequency data, are consistent with the results obtained with traditional pulsar timing techniques and comparable to high-frequency results from other PTAs. This work opens up an interesting possibility of using low-frequency wideband observations for precision pulsar timing and gravitational wave detection with similar precision as high-frequency observations used conventionally.
△ Less
Submitted 23 February, 2022; v1 submitted 13 December, 2021;
originally announced December 2021.
-
Evidence for profile changes in PSR J1713+0747 using the uGMRT
Authors:
Jaikhomba Singha,
Mayuresh P Surnis,
Bhal Chandra Joshi,
Pratik Tarafdar,
Prerna Rana,
Abhimanyu Susobhanan,
Raghav Girgaonkar,
Neel Kolhe,
Nikita Agarwal,
Shantanu Desai,
T Prabu,
Adarsh Bathula,
Subhajit Dandapat,
Lankeswar Dey,
Shinnosuke Hisano,
Ryo Kato,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Piyush Marmat,
Sai Chaitanya Susarla,
Manjari Bagchi,
Neelam Dhanda Batra,
Arpita Choudhury,
A Gopakumar,
Yashwant Gupta
, et al. (7 additional authors not shown)
Abstract:
PSR J1713+0747 is one of the most precisely timed pulsars in the international pulsar timing array experiment. This pulsar showed an abrupt profile shape change between April 16, 2021 (MJD 59320) and April 17, 2021 (MJD 59321). In this paper, we report the results from multi-frequency observations of this pulsar carried out with the upgraded Giant Metrewave Radio Telescope (uGMRT) before and after…
▽ More
PSR J1713+0747 is one of the most precisely timed pulsars in the international pulsar timing array experiment. This pulsar showed an abrupt profile shape change between April 16, 2021 (MJD 59320) and April 17, 2021 (MJD 59321). In this paper, we report the results from multi-frequency observations of this pulsar carried out with the upgraded Giant Metrewave Radio Telescope (uGMRT) before and after the event. We demonstrate the profile change seen in Band 5 (1260 MHz - 1460 MHz) and Band 3 (300 MHz - 500 MHz). The timing analysis of this pulsar shows a disturbance accompanying this profile change followed by a recovery with a timescale of $\sim 159$ days. Our data suggest that a model with chromatic index as a free parameter is preferred over models with combinations of achromaticity with DM bump or scattering bump. We determine the frequency dependence to be $\simν^{+1.34}$.
△ Less
Submitted 16 August, 2021; v1 submitted 9 July, 2021;
originally announced July 2021.
-
High Precision Measurements of Interstellar Dispersion Measure with the upgraded GMRT
Authors:
M. A. Krishnakumar,
P. K. Manoharan,
Bhal Chandra Joshi,
Raghav Girgaonkar,
Shantanu Desai,
Manjari Bagchi,
K. Nobleson,
Lankeswar Dey,
Abhimanyu Susobhanan,
Sai Chaitanya Susarla,
Mayuresh P. Surnis,
Yogesh Maan,
A. Gopakumar,
Avishek Basu,
Neelam Dhanda Batra,
Arpita Choudhary,
Kishalay De,
Yashwant Gupta,
Arun Kumar Naidu,
Dhruv Pathak,
Jaikhomba Singha,
T. Prabu
Abstract:
Pulsar radio emission undergoes dispersion due to the presence of free electrons in the interstellar medium (ISM). The dispersive delay in the arrival time of pulsar signal changes over time due to the varying ISM electron column density along the line of sight. Correcting for this delay accurately is crucial for the detection of nanohertz gravitational waves using Pulsar Timing Arrays. In this wo…
▽ More
Pulsar radio emission undergoes dispersion due to the presence of free electrons in the interstellar medium (ISM). The dispersive delay in the arrival time of pulsar signal changes over time due to the varying ISM electron column density along the line of sight. Correcting for this delay accurately is crucial for the detection of nanohertz gravitational waves using Pulsar Timing Arrays. In this work, we present in-band and inter-band DM estimates of four pulsars observed with uGMRT over the timescale of a year using two different template alignment methods. The DMs obtained using both these methods show only subtle differences for PSR 1713+0747 and J1909$-$3744. A considerable offset is seen in the DM of PSR J1939+2134 and J2145$-$0750 between the two methods. This could be due to the presence of scattering in the former and profile evolution in the latter. We find that both methods are useful but could have a systematic offset between the DMs obtained. Irrespective of the template alignment methods followed, the precision on the DMs obtained is about $10^{-3}$ pc cm$^{-3}$ using only BAND3 and $10^{-4}$ pc cm$^{-3}$ after combining data from BAND3 and BAND5 of the uGMRT. In a particular result, we have detected a DM excess of about $5\times10^{-3}$ pc cm$^{-3}$ on 24 February 2019 for PSR J2145$-$0750. This excess appears to be due to the interaction region created by fast solar wind from a coronal hole and a coronal mass ejection (CME) observed from the Sun on that epoch. A detailed analysis of this interesting event is presented.
△ Less
Submitted 1 July, 2021; v1 submitted 13 January, 2021;
originally announced January 2021.
-
pinta: The uGMRT Data Processing Pipeline for the Indian Pulsar Timing Array
Authors:
Abhimanyu Susobhanan,
Yogesh Maan,
Bhal Chandra Joshi,
T. Prabu,
Shantanu Desai,
K. Nobleson,
Sai Chaitanya Susarla,
Raghav Girgaonkar,
Lankeswar Dey,
Neelam Dhanda Batra,
Yashwant Gupta,
A. Gopakumar,
Manjari Bagchi,
Avishek Basu,
Suryarao Bethapudi,
Arpita Choudhary,
Kishalay De,
M. A. Krishnakumar,
P. K. Manoharan,
Arun Kumar Naidu,
Dhruv Pathak,
Jaikhomba Singha,
Mayuresh P. Surnis
Abstract:
We introduce pinta, a pipeline for reducing the upgraded Giant Metre-wave Radio Telescope (uGMRT) raw pulsar timing data, developed for the Indian Pulsar Timing Array experiment. We provide a detailed description of the workflow and usage of pinta, as well as its computational performance and RFI mitigation characteristics. We also discuss a novel and independent determination of the relative time…
▽ More
We introduce pinta, a pipeline for reducing the upgraded Giant Metre-wave Radio Telescope (uGMRT) raw pulsar timing data, developed for the Indian Pulsar Timing Array experiment. We provide a detailed description of the workflow and usage of pinta, as well as its computational performance and RFI mitigation characteristics. We also discuss a novel and independent determination of the relative time offsets between the different back-end modes of uGMRT and the interpretation of the uGMRT observation frequency settings, and their agreement with results obtained from engineering tests. Further, we demonstrate the capability of pinta to generate data products which can produce high-precision TOAs using PSR J1909-3744 as an example. These results are crucial for performing precision pulsar timing with the uGMRT.
△ Less
Submitted 16 April, 2021; v1 submitted 6 July, 2020;
originally announced July 2020.
-
Properties of rapidly rotating hot neutron stars with antikaon condensates at constant entropy per baryon
Authors:
Neelam Dhanda Batra,
Krishna Prakash Nunna,
Sarmistha Banik
Abstract:
We consider a neutrino-free hot neutron star that contains antikaon condensates in its core and is at finite entropy per baryon. We find the equation of state for a range of entropies and antikaon optical potentials and generate the mass profile of static as well as rotating stars. Rotation induces many changes in the stellar equilibrium, and hence its structural properties evolve. In this work, w…
▽ More
We consider a neutrino-free hot neutron star that contains antikaon condensates in its core and is at finite entropy per baryon. We find the equation of state for a range of entropies and antikaon optical potentials and generate the mass profile of static as well as rotating stars. Rotation induces many changes in the stellar equilibrium, and hence its structural properties evolve. In this work, we report the effect of rotation on the mass and shape of a hot neutron star for different equations of state and thermodynamic conditions. Temperature profile of hot, static neutron star is also explored. We also make a crude estimate of the amplitude of gravitational waves emitted by an axisymmetric rotating NS with high magnetic field.
△ Less
Submitted 27 September, 2018; v1 submitted 18 May, 2017;
originally announced May 2017.
-
The Metallicities of the Broad Emission Line Regions in the Nitrogen-Loudest Quasars
Authors:
Neelam Dhanda Batra,
Jack A. Baldwin
Abstract:
We measured the metallicity Z in the broad emission line regions (BELRs) of 43 SDSS quasars with the strongest N IV] and N III] emission lines. These N-Loud QSOs have unusually low black hole masses. We used the intensity ratio of N lines to collisionally-excited emission lines of other heavy elements to find metallicities in their BELR regions. We found that 7 of the 8 line-intensity ratios that…
▽ More
We measured the metallicity Z in the broad emission line regions (BELRs) of 43 SDSS quasars with the strongest N IV] and N III] emission lines. These N-Loud QSOs have unusually low black hole masses. We used the intensity ratio of N lines to collisionally-excited emission lines of other heavy elements to find metallicities in their BELR regions. We found that 7 of the 8 line-intensity ratios that we employed give roughly consistent metallicities as measured, but that for each individual QSO their differences from the mean of all metallicity measurements depends on the ionization potential of the ions that form the emission lines. After correcting for this effect, the different line-intensity ratios give metallicities that generally agree to within the 0.24 dex uncertainty in the measurements of the line-intensity ratios. The metallicities are very high, with mean log Z for the whole sample of 5.5 Z_sun and a maximum of 18 Z_sun. Our results argue against the possibility that the strong N lines represent an overabundance only of N but not of all heavy elements. They are compatible with either (1) the BELR gas has been chemically enriched by the general stellar population in the central bulge of the host galaxy but the Locally Optimally-emitting Cloud model used in the analysis needs some fine tuning, or (2) that instead this gas has been enriched by intense star formation on the very local scale of the active nucleus that has resulted in an abundance gradient within the BELR.
△ Less
Submitted 2 January, 2014;
originally announced January 2014.