-
Euclid. IV. The NISP Calibration Unit
Authors:
Euclid Collaboration,
F. Hormuth,
K. Jahnke,
M. Schirmer,
C. G. -Y. Lee,
T. Scott,
R. Barbier,
S. Ferriol,
W. Gillard,
F. Grupp,
R. Holmes,
W. Holmes,
B. Kubik,
J. Macias-Perez,
M. Laurent,
J. Marpaud,
M. Marton,
E. Medinaceli,
G. Morgante,
R. Toledo-Moreo,
M. Trifoglio,
Hans-Walter Rix,
A. Secroun,
M. Seiffert,
P. Stassi
, et al. (310 additional authors not shown)
Abstract:
The near-infrared calibration unit (NI-CU) on board Euclid's Near-Infrared Spectrometer and Photometer (NISP) is the first astronomical calibration lamp based on light-emitting diodes (LEDs) to be operated in space. Euclid is a mission in ESA's Cosmic Vision 2015-2025 framework, to explore the dark universe and provide a next-level characterisation of the nature of gravitation, dark matter, and da…
▽ More
The near-infrared calibration unit (NI-CU) on board Euclid's Near-Infrared Spectrometer and Photometer (NISP) is the first astronomical calibration lamp based on light-emitting diodes (LEDs) to be operated in space. Euclid is a mission in ESA's Cosmic Vision 2015-2025 framework, to explore the dark universe and provide a next-level characterisation of the nature of gravitation, dark matter, and dark energy. Calibrating photometric and spectrometric measurements of galaxies to better than 1.5% accuracy in a survey homogeneously mapping ~14000 deg^2 of extragalactic sky requires a very detailed characterisation of near-infrared (NIR) detector properties, as well their constant monitoring in flight. To cover two of the main contributions - relative pixel-to-pixel sensitivity and non-linearity characteristics - as well as support other calibration activities, NI-CU was designed to provide spatially approximately homogeneous (<12% variations) and temporally stable illumination (0.1%-0.2% over 1200s) over the NISP detector plane, with minimal power consumption and energy dissipation. NI-CU is covers the spectral range ~[900,1900] nm - at cryo-operating temperature - at 5 fixed independent wavelengths to capture wavelength-dependent behaviour of the detectors, with fluence over a dynamic range of >=100 from ~15 ph s^-1 pixel^-1 to >1500 ph s^-1 pixel^-1. For this functionality, NI-CU is based on LEDs. We describe the rationale behind the decision and design process, describe the challenges in sourcing the right LEDs, as well as the qualification process and lessons learned. We also provide a description of the completed NI-CU, its capabilities and performance as well as its limits. NI-CU has been integrated into NISP and the Euclid satellite, and since Euclid's launch in July 2023 has started supporting survey operations.
△ Less
Submitted 10 July, 2024; v1 submitted 22 May, 2024;
originally announced May 2024.
-
Euclid. III. The NISP Instrument
Authors:
Euclid Collaboration,
K. Jahnke,
W. Gillard,
M. Schirmer,
A. Ealet,
T. Maciaszek,
E. Prieto,
R. Barbier,
C. Bonoli,
L. Corcione,
S. Dusini,
F. Grupp,
F. Hormuth,
S. Ligori,
L. Martin,
G. Morgante,
C. Padilla,
R. Toledo-Moreo,
M. Trifoglio,
L. Valenziano,
R. Bender,
F. J. Castander,
B. Garilli,
P. B. Lilje,
H. -W. Rix
, et al. (412 additional authors not shown)
Abstract:
The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R>=450 slitless grism spectroscopy in the 950-2020nm wavelength range. In this reference article we illuminate the background of NISP's functional and calibration requirements, describe the instrument's integral components, and provide all its key properties. We also sketch the proc…
▽ More
The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R>=450 slitless grism spectroscopy in the 950-2020nm wavelength range. In this reference article we illuminate the background of NISP's functional and calibration requirements, describe the instrument's integral components, and provide all its key properties. We also sketch the processes needed to understand how NISP operates and is calibrated, and its technical potentials and limitations. Links to articles providing more details and technical background are included. NISP's 16 HAWAII-2RG (H2RG) detectors with a plate scale of 0.3" pix^-1 deliver a field-of-view of 0.57deg^2. In photo mode, NISP reaches a limiting magnitude of ~24.5AB mag in three photometric exposures of about 100s exposure time, for point sources and with a signal-to-noise ratio (SNR) of 5. For spectroscopy, NISP's point-source sensitivity is a SNR = 3.5 detection of an emission line with flux ~2x10^-16erg/s/cm^2 integrated over two resolution elements of 13.4A, in 3x560s grism exposures at 1.6 mu (redshifted Ha). Our calibration includes on-ground and in-flight characterisation and monitoring of detector baseline, dark current, non-linearity, and sensitivity, to guarantee a relative photometric accuracy of better than 1.5%, and relative spectrophotometry to better than 0.7%. The wavelength calibration must be better than 5A. NISP is the state-of-the-art instrument in the NIR for all science beyond small areas available from HST and JWST - and an enormous advance due to its combination of field size and high throughput of telescope and instrument. During Euclid's 6-year survey covering 14000 deg^2 of extragalactic sky, NISP will be the backbone for determining distances of more than a billion galaxies. Its NIR data will become a rich reference imaging and spectroscopy data set for the coming decades.
△ Less
Submitted 22 May, 2024;
originally announced May 2024.
-
Euclid. I. Overview of the Euclid mission
Authors:
Euclid Collaboration,
Y. Mellier,
Abdurro'uf,
J. A. Acevedo Barroso,
A. Achúcarro,
J. Adamek,
R. Adam,
G. E. Addison,
N. Aghanim,
M. Aguena,
V. Ajani,
Y. Akrami,
A. Al-Bahlawan,
A. Alavi,
I. S. Albuquerque,
G. Alestas,
G. Alguero,
A. Allaoui,
S. W. Allen,
V. Allevato,
A. V. Alonso-Tetilla,
B. Altieri,
A. Alvarez-Candal,
A. Amara,
L. Amendola
, et al. (1086 additional authors not shown)
Abstract:
The current standard model of cosmology successfully describes a variety of measurements, but the nature of its main ingredients, dark matter and dark energy, remains unknown. Euclid is a medium-class mission in the Cosmic Vision 2015-2025 programme of the European Space Agency (ESA) that will provide high-resolution optical imaging, as well as near-infrared imaging and spectroscopy, over about 14…
▽ More
The current standard model of cosmology successfully describes a variety of measurements, but the nature of its main ingredients, dark matter and dark energy, remains unknown. Euclid is a medium-class mission in the Cosmic Vision 2015-2025 programme of the European Space Agency (ESA) that will provide high-resolution optical imaging, as well as near-infrared imaging and spectroscopy, over about 14,000 deg^2 of extragalactic sky. In addition to accurate weak lensing and clustering measurements that probe structure formation over half of the age of the Universe, its primary probes for cosmology, these exquisite data will enable a wide range of science. This paper provides a high-level overview of the mission, summarising the survey characteristics, the various data-processing steps, and data products. We also highlight the main science objectives and expected performance.
△ Less
Submitted 22 May, 2024;
originally announced May 2024.
-
Euclid's Near-Infrared Spectrometer and Photometer ready for flight -- review of final performance
Authors:
E. Medinaceli,
L. Valenziano,
N. Auricchio,
E. Franceschi,
F. Gianotti,
P. Battaglia,
R. Farinelli,
A. Balestra,
S. Dusini,
C. Sirignano,
E. Borsato,
L. Stanco,
A. Renzi,
A. Troja,
L. Gabarra,
S. Ligori,
V. Capobianco,
L. Corcione,
D. Bonino,
G. Sirri,
L. Patrizii,
M. Tenti,
D. Di Ferdinando,
C. Valieri,
N. Mauri
, et al. (22 additional authors not shown)
Abstract:
ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it is equipped with the Near Infrared Spectrometer and Photometer (NISP) instrument, operating in the 0.9--2 $μ$m range. In this paper, after introducing the surve…
▽ More
ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it is equipped with the Near Infrared Spectrometer and Photometer (NISP) instrument, operating in the 0.9--2 $μ$m range. In this paper, after introducing the survey strategy, we focus our attention on the NISP Data Processing Unit's Application Software, highlighting the experimental process to obtain the final parametrization of the on-board processing of data produced by the array of 16 Teledyne HAWAII-2RG (HgCdTe) detectors. We report results from the latest ground test campaigns with the flight configuration hardware - complete optical system (Korsh anastigmat telescope), detectors array (0.56 deg$^2$ field of view), and readout systems (16 Digital Control Units and Sidecar ASICs). The performance of the on-board processing is then presented. We also describe a major issue found during the final test phase. We show how the problem was identified and solved thanks to an intensive coordinated effort of an independent review `Tiger' team, lead by ESA, and a team of NISP experts from the Euclid Consortium. An extended PLM level campaign at ambient temperature in Liège and a dedicated test campaign conducted in Marseille on the NISP EQM model eventually confirmed the resolution of the problem. Finally, we report examples of the outstanding spectrometric (using a Blue and two Red Grisms) and photometric performance of the NISP instrument, as derived from the end-to-end payload module test campaign at FOCAL 5 -- CSL; these results include the photometric Point Spread Function (PSF) determination and the spectroscopic dispersion verification.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Euclid Near Infrared Spectrometer and Photometer instrument flight model presentation, performance and ground calibration results summary
Authors:
T. Maciaszek,
A. Ealet,
W. Gillard,
K. Jahnke,
R. Barbier,
E. Prieto,
W. Bon,
A. Bonnefoi,
A. Caillat,
M. Carle,
A. Costille,
F. Ducret,
C. Fabron,
B. Foulon,
J. L. Gimenez,
E. Grassi,
M. Jaquet,
D. Le Mignant,
L. Martin,
T. Pamplona,
P. Sanchez,
J. C. Clémens,
L. Caillat,
M. Niclas,
A. Secroun
, et al. (73 additional authors not shown)
Abstract:
The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal…
▽ More
The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal control system, a detection system based on a mosaic of 16 H2RG with their front-end readout electronic, and a warm electronic system (290 K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data.
This paper presents: the final architecture of the flight model instrument and subsystems, and the performance and the ground calibration measurement done at NISP level and at Euclid Payload Module level at operational cold temperature.
△ Less
Submitted 18 October, 2022;
originally announced October 2022.
-
Euclid Near Infrared Spectro-Photometer: spatial considerations on H2RG detectors interpixel capacitance and IPC corrected conversion gain from on-ground characterization
Authors:
J. Le Graët,
A. Secroun,
R. Barbier,
W. Gillard,
JC. Clemens,
S. Conseil,
S. Escoffier,
S. Ferriol,
N. Fourmanoit,
E. Kajfasz,
S. Kermiche,
B. Kubik,
G. Smadja,
J. Zoubian
Abstract:
Euclid is a major ESA mission scheduled for launch in 2023-2024 to map the geometry of the dark Universe using two primary probes, weak gravitational lensing and galaxy clustering. \Euclid's instruments, a visible imager (VIS) and an infrared spectrometer and photometer (NISP) have both been designed and built by Euclid Consortium teams. The NISP instrument will hold a large focal plane array of 1…
▽ More
Euclid is a major ESA mission scheduled for launch in 2023-2024 to map the geometry of the dark Universe using two primary probes, weak gravitational lensing and galaxy clustering. \Euclid's instruments, a visible imager (VIS) and an infrared spectrometer and photometer (NISP) have both been designed and built by Euclid Consortium teams. The NISP instrument will hold a large focal plane array of 16 near-infrared H2RG detectors, which are key elements to the performance of the NISP, and therefore to the science return of the mission.
Euclid NISP H2RG flight detectors have been individually and thoroughly characterized at Centre de Physique des Particules de Marseille (CPPM) during a whole year with a view to producing a reference database of performance pixel maps. Analyses have been ongoing and have shown the relevance of taking into account spatial variations in deriving performance parameters. This paper will concentrate on interpixel capacitance (IPC) and conversion gain. First, per pixel IPC coefficient maps will be derived thanks to single pixel reset (SPR) measurements and a new IPC correction method will be defined and validated. Then, the paper will look into correlation effects of IPC and their impact on the derivation of per super-pixel IPC-free conversion gain maps. Eventually, several conversion gain values will be defined over clearly distinguishable regions.
△ Less
Submitted 17 November, 2023; v1 submitted 5 September, 2022;
originally announced September 2022.
-
Euclid preparation. XVIII. The NISP photometric system
Authors:
Euclid Collaboration,
M. Schirmer,
K. Jahnke,
G. Seidel,
H. Aussel,
C. Bodendorf,
F. Grupp,
F. Hormuth,
S. Wachter,
P. N. Appleton,
R. Barbier,
J. Brinchmann,
J. M. Carrasco,
F. J. Castander,
J. Coupon,
F. De Paolis,
A. Franco,
K. Ganga,
P. Hudelot,
E. Jullo,
A. Lancon,
A. A. Nucita,
S. Paltani,
G. Smadja,
L. M. G. Venancio
, et al. (198 additional authors not shown)
Abstract:
Euclid will be the first space mission to survey most of the extragalactic sky in the 0.95-2.02 $μ$m range, to a 5$σ$ point-source median depth of 24.4 AB mag. This unique photometric data set will find wide use beyond Euclid's core science. In this paper, we present accurate computations of the Euclid Y_E, J_E and H_E passbands used by the Near-Infrared Spectrometer and Photometer (NISP), and the…
▽ More
Euclid will be the first space mission to survey most of the extragalactic sky in the 0.95-2.02 $μ$m range, to a 5$σ$ point-source median depth of 24.4 AB mag. This unique photometric data set will find wide use beyond Euclid's core science. In this paper, we present accurate computations of the Euclid Y_E, J_E and H_E passbands used by the Near-Infrared Spectrometer and Photometer (NISP), and the associated photometric system. We pay particular attention to passband variations in the field of view, accounting among others for spatially variable filter transmission, and variations of the angle of incidence on the filter substrate using optical ray tracing. The response curves' cut-on and cut-off wavelengths - and their variation in the field of view - are determined with 0.8 nm accuracy, essential for the photometric redshift accuracy required by Euclid. After computing the photometric zeropoints in the AB mag system, we present linear transformations from and to common ground-based near-infrared photometric systems, for normal stars, red and brown dwarfs, and galaxies separately. A Python tool to compute accurate magnitudes for arbitrary passbands and spectral energy distributions is provided. We discuss various factors from space weathering to material outgassing that may slowly alter Euclid's spectral response. At the absolute flux scale, the Euclid in-flight calibration program connects the NISP photometric system to Hubble Space Telescope spectrophotometric white dwarf standards; at the relative flux scale, the chromatic evolution of the response is tracked at the milli-mag level. In this way, we establish an accurate photometric system that is fully controlled throughout Euclid's lifetime.
△ Less
Submitted 31 March, 2022; v1 submitted 3 March, 2022;
originally announced March 2022.
-
Autocorrelation analysis for the unbiased determination of power-law exponents in single-quantum-dot blinking
Authors:
J. Houel,
Q. T. Doan,
T. Cajgfinger,
G. Ledoux,
D. Amans,
A. Aubret,
A. Dominjon,
S. Ferriol,
R. Barbier,
M. Nasilowski,
E. Lhuillier,
B. Dubertret,
C. Dujardin,
F. Kulzer
Abstract:
We present an unbiased and robust analysis method for power-law blinking statistics in the photoluminescence of single nano-emitters, allowing us to extract both the bright- and dark-state power-law exponents from the emitters' intensity autocorrelation functions. As opposed to the widely-used threshold method, our technique therefore does not require discriminating the emission levels of bright a…
▽ More
We present an unbiased and robust analysis method for power-law blinking statistics in the photoluminescence of single nano-emitters, allowing us to extract both the bright- and dark-state power-law exponents from the emitters' intensity autocorrelation functions. As opposed to the widely-used threshold method, our technique therefore does not require discriminating the emission levels of bright and dark states in the experimental intensity timetraces. We rely on the simultaneous recording of 450 emission timetraces of single CdSe/CdS core/shell quantum dots at a frame rate of 250 Hz with single photon sensitivity. Under these conditions, our approach can determine ON and OFF power-law exponents with a precision of 3% from a comparison to numerical simulations, even for shot-noise-dominated emission signals with an average intensity below 1 photon per frame and per quantum dot. These capabilities pave the way for the unbiased, threshold-free determination of blinking power-law exponents at the micro-second timescale.
△ Less
Submitted 31 October, 2014;
originally announced October 2014.
-
GATE : a simulation toolkit for PET and SPECT
Authors:
S. Jan,
G. Santin,
D. Strul,
S. Staelens,
K. Assie,
D. Autret,
S. Avner,
R. Barbier,
M. Bardies,
P. M. Bloomfield,
D. Brasse,
V. Breton,
P. Bruyndonckx,
I. Buvat,
A. F. Chatziioannou,
Y. Choi,
Y. H. Chung,
C. Comtat,
D. Donnarieix,
L. Ferrer,
S. J. Glick,
C. J. Groiselle,
D. Guez,
P. -F. Honore,
S. Kerhoas-Cavata
, et al. (28 additional authors not shown)
Abstract:
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted…
▽ More
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.epfl.ch/GATE/.
△ Less
Submitted 24 August, 2004;
originally announced August 2004.
-
R-parity violating supersymmetry
Authors:
R. Barbier,
C. Berat,
M. Besancon,
M. Chemtob,
A. Deandrea,
E. Dudas,
P. Fayet,
S. Lavignac,
G. Moreau,
E. Perez,
Y. Sirois
Abstract:
Theoretical and phenomenological implications of R-parity violation in supersymmetric theories are discussed in the context of particle physics and cosmology. Fundamental aspects include the relation with continuous and discrete symmetries and the various allowed patterns of R-parity breaking. Recent developments on the generation of neutrino masses and mixings within different scenarios of R-pa…
▽ More
Theoretical and phenomenological implications of R-parity violation in supersymmetric theories are discussed in the context of particle physics and cosmology. Fundamental aspects include the relation with continuous and discrete symmetries and the various allowed patterns of R-parity breaking. Recent developments on the generation of neutrino masses and mixings within different scenarios of R-parity violation are discussed. The possible contribution of R-parity-violating Yukawa couplings in processes involving virtual supersymmetric particles and the resulting constraints are reviewed. Finally, direct production of supersymmetric particles and their decays in the presence of R-parity-violating couplings is discussed together with a survey of existing constraints from collider experiments.
△ Less
Submitted 13 July, 2005; v1 submitted 3 June, 2004;
originally announced June 2004.
-
A System of Interest in Spectroscopy: The qp-Rotor System
Authors:
R. Barbier,
M. Kibler
Abstract:
A rotor system, having the symmetry afforded by the two-parameter quantum algebra Uqp(u(2)), is investigated in this communication. This system is useful in rotational spectroscopy of molecules and nuclei. In particular, it is shown to lead to a model (viz., the qp-rotor model) for describing (via an energy formula and a qp-deformation of E2 reduced transition probabilities) rotational bands of…
▽ More
A rotor system, having the symmetry afforded by the two-parameter quantum algebra Uqp(u(2)), is investigated in this communication. This system is useful in rotational spectroscopy of molecules and nuclei. In particular, it is shown to lead to a model (viz., the qp-rotor model) for describing (via an energy formula and a qp-deformation of E2 reduced transition probabilities) rotational bands of deformed and superdeformed nuclei.
△ Less
Submitted 17 November, 1999;
originally announced November 1999.
-
Report of the GDR working group on the R-parity violation
Authors:
R. Barbier,
C. Berat,
M. Besancon,
P. Binetruy,
G. Bordes,
F. Brochu,
P. Bruel,
F. Charles,
C. Charlot,
M. Chemtob,
P. Coyle,
M. David,
E. Dudas,
D. Fouchez,
C. Grojean,
M. Jacquet,
S. Katsanevas,
S. Lavignac,
F. Ledroit,
R. Lopez,
A. Mirea,
G. Moreau,
C. Mulet-Marquis,
E. Nagy,
F. Naraghi
, et al. (7 additional authors not shown)
Abstract:
This report summarizes the work of the "R-parity violation group" of the French Research Network (GDR) in Supersymmetry, concerning the physics of supersymmetric models without conservation of R-parity at HERA, LEP, Tevatron and LHC and limits on R-parity violating couplings from various processes. The report includes a discussion of the recent searches at the HERA experiment, prospects for new…
▽ More
This report summarizes the work of the "R-parity violation group" of the French Research Network (GDR) in Supersymmetry, concerning the physics of supersymmetric models without conservation of R-parity at HERA, LEP, Tevatron and LHC and limits on R-parity violating couplings from various processes. The report includes a discussion of the recent searches at the HERA experiment, prospects for new experiments, a review of the existing limits, and also theoretically motivated alternatives to R-parity and a brief discussion on the implications of R-parity violation on the neutrino masses.
△ Less
Submitted 2 October, 1998;
originally announced October 1998.
-
Application of a Two-Parameter Quantum Algebra to Rotational Spectroscopy of Nuclei
Authors:
R. Barbier,
M. Kibler
Abstract:
A two-parameter quantum algebra $U_{qp}({\rm u}_2)$ is briefly investigated in this paper. The basic ingredients of a model based on the $U_{qp}({\rm u}_2)$ symmetry, the $qp$-rotator model, are presented in detail. Some general tendencies arising from the application of this model to the description of rotational bands of various atomic nuclei are summarized.
A two-parameter quantum algebra $U_{qp}({\rm u}_2)$ is briefly investigated in this paper. The basic ingredients of a model based on the $U_{qp}({\rm u}_2)$ symmetry, the $qp$-rotator model, are presented in detail. Some general tendencies arising from the application of this model to the description of rotational bands of various atomic nuclei are summarized.
△ Less
Submitted 9 February, 1996;
originally announced February 1996.
-
On the Use of Quantum Algebras in Rotation-Vibration Spectroscopy
Authors:
R. Barbier,
M. Kibler
Abstract:
A two-parameter deformation of the Lie algebra u$_2$ is used, in conjunction with the rotor system and the oscillator system, to generate a model for rotation-vibration spectroscopy of molecules and nuclei.
A two-parameter deformation of the Lie algebra u$_2$ is used, in conjunction with the rotor system and the oscillator system, to generate a model for rotation-vibration spectroscopy of molecules and nuclei.
△ Less
Submitted 13 November, 1995;
originally announced November 1995.
-
An $U_{qp}(u_2)$ Rotor Model for Rotational Bands of Superdeformed Nuclei
Authors:
R. Barbier,
J. Meyer,
M. Kibler
Abstract:
A nonrigid rotor model is developed from the two-parameter quantum algebra $U_{qp}({\rm u}_2)$. [This model presents the $U_{qp}({\rm u}_2)$ symmetry and shall be referred to as the qp-rotor model.] A rotational energy formula as well as a qp-deformation of E2 reduced transition probabilities are derived. The qp-rotor model is applied (through fitting procedures) to twenty rotational bands of su…
▽ More
A nonrigid rotor model is developed from the two-parameter quantum algebra $U_{qp}({\rm u}_2)$. [This model presents the $U_{qp}({\rm u}_2)$ symmetry and shall be referred to as the qp-rotor model.] A rotational energy formula as well as a qp-deformation of E2 reduced transition probabilities are derived. The qp-rotor model is applied (through fitting procedures) to twenty rotational bands of superdeformed nuclei in the $A \sim 130$, 150 and 190 mass regions. Systematic comparisons between the qp-rotor model and the q-rotor model of Raychev, Roussev and Smirnov, on one hand, and a basic three-parameter model, on the other hand, are performed on energy spectra, on dynamical moments of inertia and on B(E2) values. The physical signification of the deformation parameters q and p is discussed.
△ Less
Submitted 25 January, 1995;
originally announced January 1995.
-
An Uqp(u2) Model for Rotational Bands of Nuclei
Authors:
R. Barbier,
J. Meyer,
M. Kibler
Abstract:
A rotational model is developed from a new version of the two-parameter quantum algebra $U_{qp}({\rm u}_2)$. This model is applied to the description of some recent experimental data for the rotating superdeformed nuclei $^{192-194-196-198}{\rm Pb}$ and $^{192-194 }{\rm Hg}$. A comparison between the $U_{qp}({\rm u}_2)$ model presented here and the Raychev-Roussev-Smirnov model with…
▽ More
A rotational model is developed from a new version of the two-parameter quantum algebra $U_{qp}({\rm u}_2)$. This model is applied to the description of some recent experimental data for the rotating superdeformed nuclei $^{192-194-196-198}{\rm Pb}$ and $^{192-194 }{\rm Hg}$. A comparison between the $U_{qp}({\rm u}_2)$ model presented here and the Raychev-Roussev-Smirnov model with $U_{q }({\rm su}_2)$ symmetry shows the relevance of the introduction of a second parameter of a ``quantum algebra'' type.
△ Less
Submitted 11 July, 1994;
originally announced July 1994.