Noninvasive assessment of transplant-associated arteriosclerosis
- PMID: 9630101
- DOI: 10.1016/s0002-8703(98)70062-6
Noninvasive assessment of transplant-associated arteriosclerosis
Abstract
Background: Transplant-associated arteriosclerosis is the major limitation to long-term survival in the cardiac transplant recipient, and annual surveillance angiography is used in many centers to monitor its progression. Noninvasive methods would be preferable because angiography is invasive, costly, and insensitive; however, the reliability of such methods has been questioned.
Methods: All publications relating to the assessment of the cardiac allograft by noninvasive testing were identified through MEDLINE and a review of references from the published literature on transplant-associated arteriosclerosis.
Results: Resting and stress ECG, radionuclide scintigraphy, echocardiography, and positron emission tomography have all been used in cardiac transplant recipients with variable results. Most techniques are insensitive, but this limitation may be improved with pharmacologic stress imaging like dobutamine echocardiography. Although insensitive, some methods have good specificity (i.e., radionuclide scintigraphy). The noninvasive measurement of absolute coronary blood flow is promising as a specific and sensitive technique but is limited by availability and cost.
Conclusions: In general, noninvasive techniques to assess transplant-associated coronary arteriosclerosis are limited by variable sensitivity and specificity. However, certain methods, such as dobutamine echocardiography and radionuclide scintigraphy, can provide important adjunctive physiologic information to angiography. Such techniques can therefore help to guide the care and treatment of the cardiac transplant recipient with allograft coronary arteriosclerosis.
Similar articles
-
European Association of Cardiovascular Imaging/Cardiovascular Imaging Department of the Brazilian Society of Cardiology recommendations for the use of cardiac imaging to assess and follow patients after heart transplantation.Eur Heart J Cardiovasc Imaging. 2015 Sep;16(9):919-48. doi: 10.1093/ehjci/jev139. Epub 2015 Jul 2. Eur Heart J Cardiovasc Imaging. 2015. PMID: 26139361 Review.
-
Diagnosis of graft coronary artery disease.Curr Opin Cardiol. 2007 Mar;22(2):139-45. doi: 10.1097/HCO.0b013e328021066b. Curr Opin Cardiol. 2007. PMID: 17284994 Review.
-
Use of exercise electrocardiography, technetium-99m-MIBI perfusion tomography, and two-dimensional echocardiography for coronary disease surveillance in a low-prevalence population of heart transplant recipients.J Heart Lung Transplant. 1995 Mar-Apr;14(2):222-9. J Heart Lung Transplant. 1995. PMID: 7779839
-
[Evaluation of non invasive methods for the diagnosis of atherosclerosis of the graft after orthotopic cardiac transplantation].Arch Mal Coeur Vaiss. 1992 Sep;85(9):1285-90. Arch Mal Coeur Vaiss. 1992. PMID: 1290388 French.
-
Follow-up of heart transplant recipients with serial echocardiographic coronary flow reserve and dobutamine stress echocardiography to detect cardiac allograft vasculopathy.J Am Soc Echocardiogr. 2014 May;27(5):531-9. doi: 10.1016/j.echo.2014.01.020. Epub 2014 Mar 7. J Am Soc Echocardiogr. 2014. PMID: 24613313 Clinical Trial.
Cited by
-
Innervation: the missing link for biofabricated tissues and organs.NPJ Regen Med. 2020 Jun 5;5:11. doi: 10.1038/s41536-020-0096-1. eCollection 2020. NPJ Regen Med. 2020. PMID: 32550009 Free PMC article. Review.
-
Antibody-mediated rejection 16 years post-cardiac transplantation: a case report of an uncommon late presentation in a middle-aged woman.Eur Heart J Case Rep. 2019 Sep 1;3(3):ytz100. doi: 10.1093/ehjcr/ytz100. Eur Heart J Case Rep. 2019. PMID: 31365068 Free PMC article.
-
Cardiac allograft vasculopathy: diagnosis, therapy, and prognosis.Croat Med J. 2014 Dec;55(6):562-76. doi: 10.3325/cmj.2014.55.562. Croat Med J. 2014. PMID: 25559827 Free PMC article. Review.
-
Surface electrocardiography and histologic rejection following orthotopic heart transplantation.Ann Noninvasive Electrocardiol. 2005 Jan;10(1):60-4. doi: 10.1111/j.1542-474X.2005.00601.x. Ann Noninvasive Electrocardiol. 2005. PMID: 15649239 Free PMC article.
-
Perspectives on cardiac allograft vasculopathy.Curr Atheroscler Rep. 2000 May;2(3):259-71. doi: 10.1007/s11883-000-0028-x. Curr Atheroscler Rep. 2000. PMID: 11122752 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical