Linear distributed inverse solutions for interictal EEG source localisation
- PMID: 34801964
- DOI: 10.1016/j.clinph.2021.10.008
Linear distributed inverse solutions for interictal EEG source localisation
Abstract
Objective: To compare the spatial accuracy of 6 linear distributed inverse solutions for EEG source localisation of interictal epileptic discharges: Minimum Norm, Weighted Minimum Norm, Low-Resolution Electromagnetic Tomography (LORETA), Local Autoregressive Average (LAURA), Standardised LORETA, and Exact LORETA.
Methods: Spatial accuracy was assessed clinically by retrospectively comparing the maximum source of averaged interictal discharges to the resected brain area in 30 patients with successful epilepsy surgery, based on 204-channel EEG. Additionally, localisation errors of the inverse solutions were assessed in computer simulations, with different levels of noise added to the signal in both sensor space and source space.
Results: In the clinical evaluations, the source maximum was located inside the resected brain area in 50-57% of patients when using LORETA or LAURA, while all other inverse solutions performed significantly worse (17-30%; corrected p < 0.01). In the simulation studies, when noise levels exceeded 10%, LORETA and LAURA had substantially smaller localisation errors than the other inverse solutions.
Conclusions: LORETA and LAURA provided the highest spatial accuracy both in clinical and simulated data, alongside with a comparably high robustness towards noise.
Significance: Among the different linear inverse solution algorithms tested, LORETA and LAURA might be preferred for interictal EEG source localisation.
Keywords: LORETA; Local Autoregressive Average; Minimum Norm; Weighted Minimum Norm; eLORETA; sLORETA.
Copyright © 2021 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Conflict of interest statement
Declaration of Competing Interest S. Vulliemoz is shareholder and advisor of Epilog NV (Ghent, BE). All other authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
Noninvasive localization of electromagnetic epileptic activity. I. Method descriptions and simulations.Brain Topogr. 2001 Winter;14(2):131-7. doi: 10.1023/a:1012944913650. Brain Topogr. 2001. PMID: 11797811
-
Identification of Interictal Epileptic Networks from Dense-EEG.Brain Topogr. 2017 Jan;30(1):60-76. doi: 10.1007/s10548-016-0517-z. Epub 2016 Aug 22. Brain Topogr. 2017. PMID: 27549639
-
EEG based brain source localization comparison of sLORETA and eLORETA.Australas Phys Eng Sci Med. 2014 Dec;37(4):713-21. doi: 10.1007/s13246-014-0308-3. Epub 2014 Oct 31. Australas Phys Eng Sci Med. 2014. PMID: 25359588
-
Review on solving the inverse problem in EEG source analysis.J Neuroeng Rehabil. 2008 Nov 7;5:25. doi: 10.1186/1743-0003-5-25. J Neuroeng Rehabil. 2008. PMID: 18990257 Free PMC article. Review.
-
[EEG source localization using LORETA (low resolution electromagnetic tomography)].Ideggyogy Sz. 2011 Mar 30;64(3-4):110-8. Ideggyogy Sz. 2011. PMID: 21545008 Review. Hungarian.
Cited by
-
Integration of interictal EEG source localization in presurgical epilepsy evaluation - A single-center prospective study.Epilepsia Open. 2023 Sep;8(3):877-887. doi: 10.1002/epi4.12754. Epub 2023 May 19. Epilepsia Open. 2023. PMID: 37170682 Free PMC article.
-
Feasibility of high-density electric source imaging in the presurgical workflow: Effect of number of spikes and automated spike detection.Epilepsia Open. 2023 Sep;8(3):785-796. doi: 10.1002/epi4.12732. Epub 2023 Jun 1. Epilepsia Open. 2023. PMID: 36938790 Free PMC article.
-
Neural signatures of visuo-motor integration during human-robot interactions.Front Neurorobot. 2023 Jan 26;16:1034615. doi: 10.3389/fnbot.2022.1034615. eCollection 2022. Front Neurorobot. 2023. PMID: 36776553 Free PMC article.