Review
. 2017 Aug;41(6):460-479.
doi: 10.1080/03091902.2017.1333165. Epub 2017 Jun 6.

Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review

Affiliations
Review

Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review

Steven Brantlov et al. J Med Eng Technol. 2017 Aug.

Abstract

Background: Bioelectrical impedance analysis (BIA) requires a high degree of standardisation in order to ensure valid and reproducible impedance measurements. The overall aim of this review was to study the degree to which BIA papers conducted in healthy paediatric populations (aged 0-17 years) were standardised.

Methods: Literature was identified on the basis of a systematic search of internationally-recognised electronic databases and hand searching of the reference lists of the included papers in order to identify additional relevant papers. The review was limited to lead-type BIA devices for whole-body, segmental- and focal impedance measurements. In total, 71 papers published between 1988 and 2016 were included. To evaluate the degree of standardisation of the papers, a recently published review detailing critical factors that may impact on BIA measurements in children was used as a model for structuring and extracting data.

Results: There was a general lack of BIA standardisation, or its reporting, in the papers under review, which hinders comparison of data between studies and could potentially lead to erroneous measurements.

Conclusions: If the BIA technique should be accepted clinically for routine use in paediatric populations, there is a need for an increased focus on the importance of improved standardisation and its reporting in future studies. Consequently, this review contains recommendations for performing and reporting BIA measurements in a standardised manner.

Keywords: Bioelectrical impedance analysis; body composition; healthy; paediatrics; standardisation.