To read this content please select one of the options below:

Modelling and simulation of the expansion of a shape memory polymer stent

Ruoxuan Liu (International Center for Applied Mechanics, State Key Laboratory for Strength and Vibration of Mechanical Structures, Xi’an Jiaotong University, Xi’an, Shaanxi, China)
Sean Mcginty (Division of Biomedical Engineering, University of Glasgow, Glasgow, UK)
Fangsen Cui (Institute of High Performance Computing, Singapore, Singapore)
Xiaoyu Luo (Department of Mathematics, University of Glasgow, Glasgow, UK)
Zishun Liu (State Key Laboratory for Strength and Vibration School of Aerospace, Xi’an Jiaotong University, Xi’an, Shaanxi, China)

Engineering Computations

ISSN: 0264-4401

Article publication date: 10 May 2019

Issue publication date: 15 October 2019

487

Abstract

Purpose

The purpose of this paper is to demonstrate the feasibility of using shape memory polymer (SMP) for developing vascular stent. In particular, the expansion performance is analyzed through extensive modeling and simulation.

Design/methodology/approach

Firstly, the authors construct the model geometry and propose a constitutive model to describe the deformation of the stent due to the expansion process. The authors then simulate the expansion process under varying conditions, including different heating rates and recovery temperatures. Finally, the authors analyze the radial strength of the SMP stent.

Findings

A less invasive and stable expansion performance of the SMP stent is confirmed by the simulation method. A fitting function of the expansion process is proposed based on the characteristics of the SMP.

Research limitations/implications

The effects of dynamic blood flow on the SMP stent is ignored. A fluid-structure interaction analysis may need to be considered to give a more accurate description of the behaviour of the SMP stent.

Practical implications

The findings will provide guidance for the rational design and application of SMP stents.

Social implications

The work will provide guidance for the new generation stent design.

Originality/value

This is the first time that the expansion performance of a SMP stent has been analyzed both qualitatively and quantitatively through modelling and simulation.